Recall Register

2025 Gillig LOW Floor: recalls and complaints

NHTSA lists 4 recall campaigns for the 2025 Gillig LOW Floor. The newest campaign is 26V144000. NHTSA received the report on 12 Mar 2026. The NHTSA record gives the component Electrical System / Propulsion System / Cables. NHTSA has no complaint on file for this model year.

The NHTSA recall file shows no do-not-drive advisory and no park-outside advisory on these campaigns.

This page cannot show if a recall applies to one vehicle. The NHTSA VIN lookup shows the unrepaired recalls of one vehicle.

Remedy of the newest campaign, 26V144000, in the NHTSA record

Gillig will reprogram the software as an interim repair. For the final remedy, Gillig will replace the high voltage cable. Both repairs will be provided free of charge. Owner notification letters are expected to be mailed July 27, 2026. Owners may contact Gillig's customer service at 1-800-735-1500.

Complaint information entered into NHTSA’s Office of Defects Investigation vehicle owner's complaint database is used with other data sources to identify safety issues that warrant investigation and to determine if a safety-related defect trend exists.

NHTSA publishes these words. Source: NHTSA Datasets and APIs, section Complaints, read on . Complaint file through . Recall file through .

Since the last update

No tracked figure of this page changed in a data update. What the log tracks

All updates to the register

Recall campaigns

4 campaigns, newest first. 4,093 units in total.

  • 26V144000Electrical System / Propulsion System / Cables
  • 26V142000Fuel System, Diesel / Delivery / Hoses, Lines/Piping, and Fittings
  • 25V913000Suspension / Critical Fasteners
  • 25V870000Equipment Adaptive/Mobility / Wheelchair Restraints/Securement / Latch/Anchor
  1. 26V144000Received . 424 units.

    Electrical System / Propulsion System / Cables

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2023-2026 Low Floor transit buses. The high voltage cable, connecting the inverter to the drive unit, contains a splice connection that reduces the amp capacity rating.
    Consequence, in the NHTSA record
    Reduced capacity may cause the cable to overheat, increasing the risk of a fire.
    Remedy, in the NHTSA record
    Gillig will reprogram the software as an interim repair. For the final remedy, Gillig will replace the high voltage cable. Both repairs will be provided free of charge. Owner notification letters are expected to be mailed July 27, 2026. Owners may contact Gillig's customer service at 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  2. 26V142000Received . 3,568 units.

    Fuel System, Diesel / Delivery / Hoses, Lines/Piping, and Fittings

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2021-2026 Low Floor transit buses. The air compressor intake pipe may contact and damage the fuel line.
    Consequence, in the NHTSA record
    A damaged fuel line may leak, increasing the risk of a fire.
    Remedy, in the NHTSA record
    Gillig will inspect, replace, and reorient the intake pipe as necessary, free of charge. Owner notification letters were mailed April 24, 2026. Owners may contact Gillig's customer service at 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  3. 25V913000Received . 97 units.

    Suspension / Critical Fasteners

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2025 Low Floor transit buses. The rear axle upper torque rod fasteners may have been improperly tightened. A loose torque rod may contact and damage other axle components.
    Consequence, in the NHTSA record
    Damaged axle components can decrease stability or vehicle control, increasing the risk of a crash.
    Remedy, in the NHTSA record
    Gillig will replace the torque rod fasteners, free of charge. Owner notification letters were mailed January 26, 2026. Owners may contact Gillig's customer service at 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  4. 25V870000Received . 4 units.

    Equipment Adaptive/Mobility / Wheelchair Restraints/Securement / Latch/Anchor

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2025 Low Floor transit buses equipped with QRT-Deluxe and QRT-Max wheelchair restraints. The retractors may not lock, preventing the wheelchair from being properly secured.
    Consequence, in the NHTSA record
    An unsecured wheelchair can move during transit, increasing the risk of injury.
    Remedy, in the NHTSA record
    Gillig will work with Q'Straint to replace the retractors, free of charge. Owner notification letters were mailed January 16, 2026. Owners may contact Gillig customer service at 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

The campaign number opens the NHTSA record. Each quotation is the text of the NHTSA recall file.

Recall campaign: One recall in the NHTSA recall file, with one campaign number. A campaign can name many makes, models and model years.

Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.

Complaints by component

The NHTSA complaint file has no complaint for this model year.

Investigations

The NHTSA investigation file has no investigation that names this model year.

Investigation: A study of a possible safety defect by the NHTSA Office of Defects Investigation. An investigation with no closing date in the NHTSA file is open.

Other model years

The number under each year is the number of recall campaigns.

Official channels

Cite this page

Recall Register. 2025 Gillig LOW Floor: recalls and complaints. https://recallregister.com/vehicle/gillig/low-floor/2025/. Source: NHTSA Office of Defects Investigation, recall, complaint and investigation files. Data through .

Sources

Source
NHTSA Office of Defects Investigation
Licence
US government work, public domain
Recall file through
30 Sep 2026
Complaint file through
30 Sep 2026
First complaint in the file
1 Jan 1995
Manufacturer in the recall file
Gillig, LLC

The NHTSA record is the authority. A complaint count is the number of different complaint numbers for the make, the model and the model year. How the register is made. Report an error.

Questions

How many units are in the recall campaigns for the 2025 Gillig LOW Floor?
4,093 units in 4 campaigns. A campaign can name other models and model years, and its units include them.
How many recall campaigns does the Gillig LOW Floor have for all model years?
NHTSA lists 90 recall campaigns for the Gillig LOW Floor, model years 1997 to 2026. 4 of them name the 2025 model year.
Is an NHTSA investigation of the 2025 Gillig LOW Floor open?
The NHTSA investigation file has no investigation that names this model year.