Recall Register

2022 Gillig LOW Floor: recalls and complaints

NHTSA lists 11 recall campaigns for the 2022 Gillig LOW Floor. The newest campaign is 26V142000. NHTSA received the report on 12 Mar 2026. The NHTSA record gives the component Fuel System, Diesel / Delivery / Hoses, Lines/Piping, and Fittings. NHTSA has no complaint on file for this model year.

The NHTSA recall file shows no do-not-drive advisory and no park-outside advisory on these campaigns.

This page cannot show if a recall applies to one vehicle. The NHTSA VIN lookup shows the unrepaired recalls of one vehicle.

Remedy of the newest campaign, 26V142000, in the NHTSA record

Gillig will inspect, replace, and reorient the intake pipe as necessary, free of charge. Owner notification letters were mailed April 24, 2026. Owners may contact Gillig's customer service at 1-800-735-1500.

Complaint information entered into NHTSA’s Office of Defects Investigation vehicle owner's complaint database is used with other data sources to identify safety issues that warrant investigation and to determine if a safety-related defect trend exists.

NHTSA publishes these words. Source: NHTSA Datasets and APIs, section Complaints, read on . Complaint file through . Recall file through .

Since the last update

No tracked figure of this page changed in a data update. What the log tracks

All updates to the register

Recall campaigns

11 campaigns, newest first. 14,101 units in total.

  • 26V142000Fuel System, Diesel / Delivery / Hoses, Lines/Piping, and Fittings
  • 25V076000Equipment / Appliance / Tv/Radio/Speakers
  • 24V958000Equipment / Emergency / Fire Supression / Wiring
  • 23V812000Visibility / Rearview Mirrors/Devices
  • 23V740000Power Train / Driveline / Driveshaft
  • 23V635000Power Train / Driveline / Driveshaft
  • 23V356000Electrical System
  • 23V075000Steering / Linkages / Drag / Link / Connection
  • 22V801000Steering
  • 22V548000Electrical System / Propulsion System / Traction Battery
  • 22V436000Electrical System / Propulsion System / Cables / Fastener/Connector
  1. 26V142000Received . 3,568 units.

    Fuel System, Diesel / Delivery / Hoses, Lines/Piping, and Fittings

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2021-2026 Low Floor transit buses. The air compressor intake pipe may contact and damage the fuel line.
    Consequence, in the NHTSA record
    A damaged fuel line may leak, increasing the risk of a fire.
    Remedy, in the NHTSA record
    Gillig will inspect, replace, and reorient the intake pipe as necessary, free of charge. Owner notification letters were mailed April 24, 2026. Owners may contact Gillig's customer service at 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  2. 25V076000Received . 91 units.

    Equipment / Appliance / Tv/Radio/Speakers

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2019-2024 Low Floor transit buses. The rivet-nut fasteners that secure the TFT flat panel display monitor to the bus ceiling may fail, causing the monitor to detach and fall.
    Consequence, in the NHTSA record
    A monitor that detaches and falls from the ceiling increases the risk of injury.
    Remedy, in the NHTSA record
    Gillig will replace the rivet-nut fasteners, free of charge. Owner notification letters were mailed March 18, 2025. Owners may contact Gillig customer service at 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  3. 24V958000Received . 201 units.

    Equipment / Emergency / Fire Supression / Wiring

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2021-2024 Low Floor style transit buses. The fire suppression relay cable may be damaged, chafing against the mounting bolt, and fail.
    Consequence, in the NHTSA record
    Failure of the fire suppression system can increase the risk of injury during a fire.
    Remedy, in the NHTSA record
    Dealers will replace the relay cable, free of charge. Owner notification letters were mailed December 31, 2024. Owners may contact GILLIG customer service at 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  4. 23V812000Received . 3,626 units.

    Visibility / Rearview Mirrors/Devices

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2021-2023 Low Floor vehicles. The rearview mirror electric adjustment system may have been manufactured with an incorrect fuse.
    Consequence, in the NHTSA record
    An incorrect fuse may overheat and increase the risk of a fire.
    Remedy, in the NHTSA record
    Gillig will replace the protection fuse of the mirror control switch, free of charge. Owner notification letters were mailed January 15, 2024. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  5. 23V740000Received . 4,286 units.

    Power Train / Driveline / Driveshaft

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2019-2023 Low Floor transit buses. The transmission yoke may separate, resulting in driveshaft separation and a sudden loss of drive power.
    Consequence, in the NHTSA record
    A sudden loss of drive power can increase the risk of a crash. Additionally, a disabled bus may require an evacuation procedure in an uncontrolled traffic situation, increasing the risk of injury to passengers.
    Remedy, in the NHTSA record
    Gillig will work with the equipment manufacturer, Allison Transmission Inc., to inspect and tighten the transmission yoke bolts, as necessary, free of charge. Owner notification letters were mailed December 11, 2023. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  6. 23V635000Received . 223 units.

    Power Train / Driveline / Driveshaft

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2022-2023 Low Floor transit buses. The driveshaft fasteners may have been improperly tightened after service repairs, allowing the driveshaft to detach.
    Consequence, in the NHTSA record
    A detached driveshaft can cause a loss of vehicle control, increasing the risk of a crash.
    Remedy, in the NHTSA record
    Gillig will replace the driveshaft straps and fasteners, free of charge. Owner notification letters were mailed October 9, 2023. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  7. 23V356000Received . 30 units.

    Electrical System

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2022 Low Floor CNG transit buses. An electrical failure may cause a short-circuit in the fuse box mounted underneath the driver's seat platform.
    Consequence, in the NHTSA record
    An electrical short-circuit can increase the risk of a fire.
    Remedy, in the NHTSA record
    Gillig will provide new busbars, free of charge. Owner notification letters were mailed July 20, 2023. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  8. 23V075000Received . 1,335 units.

    Steering / Linkages / Drag / Link / Connection

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2022-2023 Low Floor transit and shuttle buses. Incompatible steering system draglink parts may have been installed during the vehicle assembly process, potentially resulting in long-term damage of the steering system.
    Consequence, in the NHTSA record
    A damaged steering system can result in a loss of vehicle handling and control, increasing the risk of a crash.
    Remedy, in the NHTSA record
    Gillig will inspect and, when necessary, replace and tighten the draglink rod, free of charge. Owner notification letters were mailed March 29, 2023. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  9. 22V801000Received . 388 units.

    Steering

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2022 Low Floor transit buses. The steering shaft grease fitting may contact and damage the protective shroud.
    Consequence, in the NHTSA record
    Contact between the steering shaft grease fitting and shroud can result in a loss of steering control, increasing the risk of a crash.
    Remedy, in the NHTSA record
    Gillig will install a low-profile grease fitting and spacer shim, free of charge. Owner notification letters are expected to be mailed December 1, 2022. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  10. 22V548000Received . 184 units.

    Electrical System / Propulsion System / Traction Battery

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2019-2022 Low Floor vehicles equipped with Cummins BP74E battery packs. The battery packs may develop a coolant leak internally, causing the battery pack to short circuit.
    Consequence, in the NHTSA record
    A battery short circuit increases the risk of a fire.
    Remedy, in the NHTSA record
    Gillig will tighten the coolant fittings and replace the coolant, free of charge. Owner notification were mailed on August 16, 2022. Owners may contact Gillig's customer service at 1-510-264-5073 or 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

  11. 22V436000Received . 169 units.

    Electrical System / Propulsion System / Cables / Fastener/Connector

    Defect, in the NHTSA record
    Gillig, LLC (Gillig) is recalling certain 2019-2022 Low Floor electric transit buses. The EV resolver cable connector may experience a loss of electrical connectivity, unexpectedly switching from Drive to Neutral with no warning.
    Consequence, in the NHTSA record
    An unexpected switch to neutral can cause a loss of vehicle propulsion and increase the risk of a crash.
    Remedy, in the NHTSA record
    Dealers will install a redesigned resolver cable with extended length and a new support bracket, free of charge. Owner notification letters were mailed on August 3, 2022. Owners may contact Gillig's customer service at 1-510-264-5073 or 1-800-735-1500.

    Report filed by Gillig, LLC. Owner notification date in the NHTSA record: .

The campaign number opens the NHTSA record. Each quotation is the text of the NHTSA recall file.

Recall campaign: One recall in the NHTSA recall file, with one campaign number. A campaign can name many makes, models and model years.

Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.

Complaints by component

The NHTSA complaint file has no complaint for this model year.

Investigations

The NHTSA investigation file has no investigation that names this model year.

Investigation: A study of a possible safety defect by the NHTSA Office of Defects Investigation. An investigation with no closing date in the NHTSA file is open.

Other model years

The number under each year is the number of recall campaigns.

Official channels

Cite this page

Recall Register. 2022 Gillig LOW Floor: recalls and complaints. https://recallregister.com/vehicle/gillig/low-floor/2022/. Source: NHTSA Office of Defects Investigation, recall, complaint and investigation files. Data through .

Sources

Source
NHTSA Office of Defects Investigation
Licence
US government work, public domain
Recall file through
30 Sep 2026
Complaint file through
30 Sep 2026
First complaint in the file
1 Jan 1995
Manufacturer in the recall file
Gillig, LLC

The NHTSA record is the authority. A complaint count is the number of different complaint numbers for the make, the model and the model year. How the register is made. Report an error.

Questions

How many units are in the recall campaigns for the 2022 Gillig LOW Floor?
14,101 units in 11 campaigns. A campaign can name other models and model years, and its units include them.
How many recall campaigns does the Gillig LOW Floor have for all model years?
NHTSA lists 90 recall campaigns for the Gillig LOW Floor, model years 1997 to 2026. 11 of them name the 2022 model year.
Is an NHTSA investigation of the 2022 Gillig LOW Floor open?
The NHTSA investigation file has no investigation that names this model year.