Recall Register

2002 Orion VII: recalls and complaints

NHTSA lists 6 recall campaigns for the 2002 Orion VII. The newest campaign is 13V476000. NHTSA received the report on 27 Sep 2013. The NHTSA record gives the component Electrical System. NHTSA has no complaint on file for this model year. 1 NHTSA investigation names this model year.

The NHTSA recall file shows no do-not-drive advisory and no park-outside advisory on these campaigns.

This page cannot show if a recall applies to one vehicle. The NHTSA VIN lookup shows the unrepaired recalls of one vehicle.

Remedy of the newest campaign, 13V476000, in the NHTSA record

DBNA will notify owners and Sure Power representatives will change out the equalizer and/or convertor, free of charge. The recall is expected to begin during November 2014. Owners may contact DBNA at 1-905-403-1111.

Complaint information entered into NHTSA’s Office of Defects Investigation vehicle owner's complaint database is used with other data sources to identify safety issues that warrant investigation and to determine if a safety-related defect trend exists.

NHTSA publishes these words. Source: NHTSA Datasets and APIs, section Complaints, read on . Complaint file through . Recall file through .

Since the last update

No tracked figure of this page changed in a data update. What the log tracks

All updates to the register

Recall campaigns

6 campaigns, newest first. 5,599 units in total.

  • 13V476000Electrical System
  • 10V015000Power Train / Clutch Assembly / Pedal/Hand Lever(Motorcycle)
  • 09V413000Interior Lighting
  • 05V282000Structure / Body / Door
  • 04V447000Latches/Locks/Linkages
  • 04V411000Fuel System, Other / Storage
  1. 13V476000Received . 3,009 units.

    Electrical System

    Defect, in the NHTSA record
    Daimler Buses North America Ltd. (DBNA) is recalling certain model year 2003-2008 Orion V and model year 2002-2010 VII buses equipped with Sure Power equalizers and DC-DC Converters. The specific potting compound used in the equalizers and convertors for insulation was found to be capable of conducting electricity after being exposed to heat.
    Consequence, in the NHTSA record
    Once electrically conductive, the material is capable of melting and burning, increasing the risk of a fire.
    Remedy, in the NHTSA record
    DBNA will notify owners and Sure Power representatives will change out the equalizer and/or convertor, free of charge. The recall is expected to begin during November 2014. Owners may contact DBNA at 1-905-403-1111.

    Report filed by Daimler Buses North America. Owner notification date in the NHTSA record: .

  2. 10V015000Received . 426 units.

    Power Train / Clutch Assembly / Pedal/Hand Lever(Motorcycle)

    Defect, in the NHTSA record
    Daimler buses is recalling certain orion transit buses equipped with the morse remote throttle control. The morse remote throttle control panel is located in the engine compartment and a switch on it is labeled, "throttle"; "off" or "front" and "on" or "rear" selecting the active engine control station. If a person operating the engine from the "rear" position (at the engine) fails to place the switch in the "off" or "front" position and the engine RPM was set to above idle during maintenance for example, when the bus is started from the driver's station the engine could change to the higher RPM resulting in unwanted engine power.
    Consequence, in the NHTSA record
    The bus could accelerate at a higher rate than anticipated increasing the risk of a crash.
    Remedy, in the NHTSA record
    Daimler will provide instructions to modify the wiring to the morse throttle control switch. This service will be performed free of charge. The safety recall began on april 1, 2010. Owners may contact daimler buses at 1-800-716-7466.

    Report filed by DAIMLER BUSES NORTH AMERICA, INC.. Owner notification date in the NHTSA record: .

  3. 09V413000Received . 368 units.

    Interior Lighting

    Defect, in the NHTSA record
    Daimler buses of north america is recalling certain model year 2002 through 2009 orion transit buses equipped with luminator horizon LED side destination signs. The connector board can corrode due to an accumulation of moisture under the connector.
    Consequence, in the NHTSA record
    A short could occur, possibly causing smoke and a fire.
    Remedy, in the NHTSA record
    Orion will notify owners and the buses will be repaired by luminator free of charge. Please see luminator's defect report 09e-054. The safety recall is expected to begin during november 2009. Owners may contact luminator at 1-972-516-3033 or orion at 1-800-716-7466.

    Report filed by DAIMLER BUSES NORTH AMERICA, INC..

  4. 05V282000Received . 1,092 units.

    Structure / Body / Door

    Defect, in the NHTSA record
    On certain commercial buses equipped with vapor door assemblies, the two piece curved connecting rods when used as an element of the door actuation linkage in conjunction with a vapor medium pneumatic differential engine, may be subject to fatigue failure resulting in bending or breaking of the connecting rod.
    Consequence, in the NHTSA record
    A broken connecting rod can allow the door panel to move freely in an uncontrolled manner, leaving passengers inside the vehicle unprotected by the door panel and enabling a protruding door panel to strike persons or objects outside the vehicle.
    Remedy, in the NHTSA record
    Orion is working with vapor bus international to notify owners and have the repair performed on their vehicles. The remedy consists of replacing the two piece connecting rod with a one piece connecting rod. Owners may contact orion bus at 905-403-7832 or vapor at 847-777-6400.

    Report filed by ORION BUS INDUSTRIES LTD..

  5. 04V447000Received . 452 units.

    Latches/Locks/Linkages

    Defect, in the NHTSA record
    On certain buses, the battery storage sliding tray locking toggle was not tightened sufficiently. The battery door can open allowing the battery tray to slide out from the stored position.
    Consequence, in the NHTSA record
    This could cause an obstacle, which could result in a crash.
    Remedy, in the NHTSA record
    Dealers will inspect and add a locking pin to keep the battery tray from sliding. Orion has not yet provided an owner notification schedule for this campaign. Customers may also contact orion at 1-905-403-7832.

    Report filed by ORION BUS INDUSTRIES LTD.. Owner notification date in the NHTSA record: .

  6. 04V411000Received . 252 units.

    Fuel System, Other / Storage

    Defect, in the NHTSA record
    Certain buses equipped with compressed natural gas fuel containers, model alt823d, p/n 1273147, do not conform to the requirements of federal motor vehicle safety standard no. 304, 'compressed natural gas fuel container integrity.' the ngv container's pressure relief devices fail to timely and fully activate as required by the standard.
    Consequence, in the NHTSA record
    In the event of a vehicle fire with the fuel system roof enclosure removed or opened, the fuel container's pressure relief devices may not activate as they are designed to do and the fuel container could rupture and explode. Such an explosion could cause serious injuries or death to occupants of the bus or to persons outside the bus.
    Remedy, in the NHTSA record
    Structural composites will notify the orion bus owners. Structural composites has not yet provided the agency with a finalized remedy. Owners should contact sci at 1-909-444-2503 or orion at 1-905-403-7832.

    Report filed by ORION BUS INDUSTRIES LTD..

The campaign number opens the NHTSA record. Each quotation is the text of the NHTSA recall file.

Recall campaign: One recall in the NHTSA recall file, with one campaign number. A campaign can name many makes, models and model years.

Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.

Complaints by component

The NHTSA complaint file has no complaint for this model year.

Investigations

NHTSA investigations that name the 2002 Orion VII
NumberTypeSubjectComponentOpenedClosedCampaign
PE04074Preliminary evaluationHYDRAULIC FAN FITTINGS LEAKINGEngine and Engine Cooling / Cooling System / Fan2 Nov 200417 Dec 200404V544000

Investigation: A study of a possible safety defect by the NHTSA Office of Defects Investigation. An investigation with no closing date in the NHTSA file is open.

Other model years

The number under each year is the number of recall campaigns.

  1. 20012
  2. 20026
  3. 20037
  4. 200413
  5. 200511
  6. 20069
  7. 20079
  8. 200811
  9. 20098
  10. 20105
  11. 20114
  12. 20124

A year without a link has fewer than 2 campaigns and fewer than 25 complaints. It has no page.

Official channels

Cite this page

Recall Register. 2002 Orion VII: recalls and complaints. https://recallregister.com/vehicle/orion/vii/2002/. Source: NHTSA Office of Defects Investigation, recall, complaint and investigation files. Data through .

Sources

Source
NHTSA Office of Defects Investigation
Licence
US government work, public domain
Recall file through
30 Sep 2026
Complaint file through
30 Sep 2026
First complaint in the file
1 Jan 1995
Manufacturer in the recall file
Daimler Buses North America

The NHTSA record is the authority. A complaint count is the number of different complaint numbers for the make, the model and the model year. How the register is made. Report an error.

Questions

How many units are in the recall campaigns for the 2002 Orion VII?
5,599 units in 6 campaigns. A campaign can name other models and model years, and its units include them.
How many recall campaigns does the Orion VII have for all model years?
NHTSA lists 26 recall campaigns for the Orion VII, model years 2001 to 2012. 6 of them name the 2002 model year.
Is an NHTSA investigation of the 2002 Orion VII open?
No. The 1 investigation that names this model year has a closing date in the NHTSA file.