Recall Register

Food, drugs, devices › Siemens Medical Solutions USA, Inc

Device recall: Interventional Fluoroscopic X-Ray System: LUMINOS Q.namix R; Siemens Material Number (SMN): 11574002; With Software Vers

FDA enforcement event 98244 · Class II · initiated 29 Dec 2025 · status Ongoing

DeviceVoluntary: Firm initiated2 product recordsMalvern, PA

Siemens Medical Solutions USA, Inc (Malvern, PA) initiated this device recall on 29 Dec 2025; FDA lists 2 product records under event 98244, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 85% of the 945 device enforcement events initiated in 2025 carry the same class.

Status: Ongoing. Initiation: voluntary: firm initiated. Siemens Medical Solutions USA, Inc has 400 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Siemens Medical Solutions USA, Inc, Malvern, PA.

Reason for recall

"Ortho images acquired with preset automatic horizontal flip are not flipped and when acquiring single images, there is the possibility that an image of a previous patient may be processed."

Distribution

"Worldwide - US Nationwide distribution in the states of AK, CA, IL, MN, NY, OR, VA, WI and the countries of Austria, Belgium, Denmark, France, Germany, Greece, Ireland, Italy, Netherlands, Norway,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-1174-2026Interventional Fluoroscopic X-Ray System: LUMINOS Q.namix R; Siemens Material Number (SMN): 11574002; With Software Version VB10D-SP0241 unitsClass IIOngoing4 Feb 2026
Z-1175-2026Interventional Fluoroscopic X-Ray System: LUMINOS Q.namix T; Siemens Material Number (SMN): 11574003; With Software Version VB10D-SP027 unitsClass IIOngoing4 Feb 2026

Context

85%of 2025 device events are Class II945 events that year
2product records in this eventfirm median: 1
400events on this register for the firm

Other enforcement events for Siemens Medical Solutions USA, Inc

InitiatedProduct (first record)TypeClassRecords
8 Jun 2026ARTIS icono ceiling. Model Number: 11328100.DeviceClass II1
20 May 2026ARTIS icono biplane. Model Number: 11327600.DeviceClass II3
12 Mar 2026ARTIS Pheno VE30A and VE40A, Model 10849000DeviceClass II1
10 Mar 2026ARTIS pheno and ARTIS Icono biplane, floor and ceiling. Model Numbers 10849000, 11327600, 11328100, 11327700.DeviceClass II1
9 Mar 2026ARTIS pheno, Model 10849000. interventional fluoroscopic x-ray systemDeviceClass II2
19 Dec 2025SOMATOM X.ceed Software applications: syngo.CT Brain Quantification syngo.CT Vessel Hyperdensities syngo.CT ASPECTSDeviceClass II4
5 Dec 2025LUMINOS Lotus Max, Model 11574100 and Luminos dRF Max, Model 10762471DeviceClass II1
24 Oct 2025MAMMOMAT Revelation;DeviceClass II3
1 Oct 2025MAGNETOM Cima.X Upgrade. Model Number: 11689304.DeviceClass I1
28 Aug 2025Biograph mMR. Model Number: 10433372.DeviceClass I15

All 400 events for Siemens Medical Solutions USA, Inc

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Ortho images acquired with preset automatic horizontal flip are not flipped and when acquiring single images, there is the possibility that an image of a previous patient may be processed."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide - US Nationwide distribution in the states of AK, CA, IL, MN, NY, OR, VA, WI and the countries of Austria, Belgium, Denmark, France, Germany, Greece, Ireland, Italy, Netherlands, Norway,…"

Is the recall still ongoing?

FDA lists the status as Ongoing. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.