Device recall: MAGNETOM Cima.X Upgrade. Model Number: 11689304.

FDA enforcement event 97845 · Class I · initiated 1 Oct 2025 · status Ongoing

DeviceVoluntary: Firm initiated1 product recordMalvern, PA

Siemens Medical Solutions USA, Inc (Malvern, PA) initiated this device recall on 1 Oct 2025; FDA lists 1 product record under event 97845, classified Class I.

FDA defines Class I as a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death. 13% of the 945 device enforcement events initiated in 2025 carry the same class.

Status: Ongoing. Initiation: voluntary: firm initiated. Siemens Medical Solutions USA, Inc has 400 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Siemens Medical Solutions USA, Inc, Malvern, PA.

Reason for recall

"There is a potential for an ice blockage to form or currently exist within the primary and/or the auxiliary venting paths of the magnet helium containment venting system. In the event of a quench when both venting paths are blocked, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up…"

Distribution

"US distribution to California. International distribution to Australia, Germany, Great Britian."

Product records

Recall numberProductQuantityClassStatusReport date
Z-0431-2026MAGNETOM Cima.X Upgrade. Model Number: 11689304.4 system (1 US; 3 OUS)Class IOngoing19 Nov 2025

Context

13%of 2025 device events are Class I945 events that year
1product record in this eventfirm median: 1
400events on this register for the firm

Other enforcement events for Siemens Medical Solutions USA, Inc

InitiatedProduct (first record)TypeClassRecords
8 Jun 2026ARTIS icono ceiling. Model Number: 11328100.DeviceClass II1
20 May 2026ARTIS icono biplane. Model Number: 11327600.DeviceClass II3
12 Mar 2026ARTIS Pheno VE30A and VE40A, Model 10849000DeviceClass II1
10 Mar 2026ARTIS pheno and ARTIS Icono biplane, floor and ceiling. Model Numbers 10849000, 11327600, 11328100, 11327700.DeviceClass II1
9 Mar 2026ARTIS pheno, Model 10849000. interventional fluoroscopic x-ray systemDeviceClass II2
29 Dec 2025Interventional Fluoroscopic X-Ray System: LUMINOS Q.namix R; Siemens Material Number (SMN): 11574002; With Software VersDeviceClass II2
19 Dec 2025SOMATOM X.ceed Software applications: syngo.CT Brain Quantification syngo.CT Vessel Hyperdensities syngo.CT ASPECTSDeviceClass II4
5 Dec 2025LUMINOS Lotus Max, Model 11574100 and Luminos dRF Max, Model 10762471DeviceClass II1
24 Oct 2025MAMMOMAT Revelation;DeviceClass II3
28 Aug 2025Biograph mMR. Model Number: 10433372.DeviceClass I15

All 400 events for Siemens Medical Solutions USA, Inc

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "There is a potential for an ice blockage to form or currently exist within the primary and/or the auxiliary venting paths of the magnet helium containment venting system. In the event of a quench when both venting paths are blocked, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up…"

What does Class I mean?

FDA classifies recalls by relative degree of health hazard. Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.

Where was the product distributed?

FDA's distribution pattern field reads: "US distribution to California. International distribution to Australia, Germany, Great Britian."

Is the recall still ongoing?

FDA lists the status as Ongoing. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.