2001 Fleetwood American Eagle: recalls and complaints

NHTSA lists 4 recall campaigns for the 2001 Fleetwood American Eagle. The newest campaign is 09V312000. NHTSA received the report on 28 Jul 2009. The NHTSA record gives the component Equipment. NHTSA has 2 complaints on file for this model year.

The NHTSA recall file shows no do-not-drive advisory and no park-outside advisory on these campaigns.

This page cannot show if a recall applies to one vehicle. The NHTSA VIN lookup shows the unrepaired recalls of one vehicle.

Remedy of the newest campaign, 09V312000, in the NHTSA record

Fleetwood RV will notify owners and the vehicle's refrigerator will be repaired free of charge. The safety recall is expected to begin during september 2009. Owners may contact fleetwood RV at 1-800-509-3418 or norcold's recall center at 1-800-767-9101.

Complaint information entered into NHTSA’s Office of Defects Investigation vehicle owner's complaint database is used with other data sources to identify safety issues that warrant investigation and to determine if a safety-related defect trend exists.

NHTSA publishes these words. Source: NHTSA Datasets and APIs, section Complaints, read on . Complaint file through . Recall file through .

Since the last update

No tracked figure of this page changed in a data update. What the log tracks

All updates to the register

Recall campaigns

4 campaigns, newest first. 175,183 units in total.

  • 09V312000Equipment
  • 08V240000Equipment / Recreational Vehicle/Trailer
  • 07V120000Equipment / Recreational Vehicle/Trailer
  • 01V009000Exterior Lighting / Headlights
  1. 09V312000Received . 6,684 units.

    Equipment

    Defect, in the NHTSA record
    Fleetwood RV is recalling certain model year 2005 and 2006 motorhomes manufactured between july 24, 2004 and march 11, 2005, equipped with norcold model 1200lr, 1200lrim, and 1201lrim refrigerators with serial numbers between 1273701 and 1536607, non-consecutively. A fatigue failure in the section of the cooling unit which contains the refrigerant could allow the liquid solution to slowly leak. If a leak occurs and the refrigerator continues to be operated after solution circulation has ceased the heat source could generate very high temperatures. At such high temperatures, the cooling unit could rupture.
    Consequence, in the NHTSA record
    If a leak occurs and the unit is continues to operate, hydrogen gas may be expelled and can be ignited, resulting in a fire, possibly causing serious injury or death.
    Remedy, in the NHTSA record
    Fleetwood RV will notify owners and the vehicle's refrigerator will be repaired free of charge. The safety recall is expected to begin during september 2009. Owners may contact fleetwood RV at 1-800-509-3418 or norcold's recall center at 1-800-767-9101.

    Report filed by FLEETWOOD RV, INC..

  2. 08V240000Received . 1,263 units.

    Equipment / Recreational Vehicle/Trailer

    Defect, in the NHTSA record
    Fleetwood is recalling certain class a gas and diesel motor homes, class c motor homes, conventional and fifth wheel travel trailers equipped with norcold refrigerators. A low cycle fatigue failure in the section of the cooling unit which generates the refrigerant could allow the liquid solution to slowly leak.
    Consequence, in the NHTSA record
    Extended operation of a leaking cooling unit could lead to a fire from gas which might escape.
    Remedy, in the NHTSA record
    Fleetwood is working with norcold to repair these refrigerators. Norcold will provide thermal switch kits to owners along with the necessary forms and instructions. The recall is expected to begin during june 2008. Owners may contact norcold at 1-800-767-9101 or fleetwood at 1-800-509-3418.

    Report filed by FLEETWOOD ENTERPRISES, INC.. Owner notification date in the NHTSA record: .

  3. 07V120000Received . 167,096 units.

    Equipment / Recreational Vehicle/Trailer

    Defect, in the NHTSA record
    Certain motor homes and travel trailers equipped with a two-door refrigerator, manufactured by the dometic corporation, may have a defect in the boiler tube. Pressurized coolant solution could be released into an area where an ignition source (gas flame) is present.
    Consequence, in the NHTSA record
    Release of coolant under certain conditions could ignite and result in a fire.
    Remedy, in the NHTSA record
    Fleetwood will be working with dometic in order to repair these refrigerators (please see 06e076). Dometic will repair these refrigerators by installing a secondary burn housing, a thermal fuse, and a melt fuse free of charge. Dometic has retained stericycle INC. To manage this campaign. Stericycle will assist you in locating dealerships or service centers and will provide assistance with scheduling of appointments. Owners may contact dometic/stericycle at 1-888-446-5157 or fleetwood at 1-800-322-8216.

    Report filed by FLEETWOOD ENTERPRISES, INC.. Owner notification date in the NHTSA record: .

  4. 01V009000Received . 140 units.

    Exterior Lighting / Headlights

    Defect, in the NHTSA record
    Vehicle description: certain motor homes fail to comply with the requirements of FMVSS no. 108, "lamps, reflective devices, and associated equipment." the wiring to the headlamp assemblies is incorrect causing a low brightness of the headlamps.
    Consequence, in the NHTSA record
    This reduced lighting level will affect driver visibility.
    Remedy, in the NHTSA record
    Dealers will rewire the connectors that plug into the headlamps. Owner notification began january 26, 2001. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact fleetwood at 1-800-445-3307.

    Report filed by FLEETWOOD ENT., INC.. Owner notification date in the NHTSA record: .

The campaign number opens the NHTSA record. Each quotation is the text of the NHTSA recall file.

Recall campaign: One recall in the NHTSA recall file, with one campaign number. A campaign can name many makes, models and model years.

Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.

Complaints by component

2 complaints, 2 component mentions.

A complaint can name more than one component. Each component that a complaint names is one component mention. This model year has fewer than 50 component mentions, so the table shows the number of mentions only.

2001 Fleetwood American Eagle: component mentions in complaints
ComponentMentions
Service Brakes, Hydraulic1
Tires1
Complaints that report a crash
0
Complaints that report a fire
0
Injuries in the complaints
0
Deaths in the complaints
0
Date of the newest complaint
2 Sep 2010

These figures are the entries of the persons who sent the complaints.

Complaint: A report about a possible safety problem that a person sends to NHTSA. This site shows the number of complaints and not their text.

Complaints about the 2001 Fleetwood American Eagle, by the year NHTSA received them. The largest year is 2001, with 1 complaint.

Investigations

The NHTSA investigation file has no investigation that names this model year.

Investigation: A study of a possible safety defect by the NHTSA Office of Defects Investigation. An investigation with no closing date in the NHTSA file is open.

Other model years

The number under each year is the number of recall campaigns.

  1. 19911
  2. 19921
  3. 19931
  4. 19941
  5. 19951
  6. 19961
  7. 19972
  8. 19984
  9. 19996
  10. 20004
  11. 20014
  12. 20023
  13. 20034
  14. 20048
  15. 20054
  16. 20061
  17. 20074
  18. 20083
  19. 20092
  20. 20102
  21. 20112

A year without a link has fewer than 2 campaigns and fewer than 25 complaints. It has no page.

Official channels

Cite this page

Recall Register. 2001 Fleetwood American Eagle: recalls and complaints. https://recallregister.com/vehicle/fleetwood/american-eagle/2001/. Source: NHTSA Office of Defects Investigation, recall, complaint and investigation files. Data through .

Sources

Source
NHTSA Office of Defects Investigation
Licence
US government work, public domain
Recall file through
30 Sep 2026
Complaint file through
30 Sep 2026
First complaint in the file
1 Jan 1995
Manufacturer in the recall file
FLEETWOOD RV, INC.

The NHTSA record is the authority. A complaint count is the number of different complaint numbers for the make, the model and the model year. How the register is made. Report an error.

Questions

How many units are in the recall campaigns for the 2001 Fleetwood American Eagle?
175,183 units in 4 campaigns. A campaign can name other models and model years, and its units include them.
How many recall campaigns does the Fleetwood American Eagle have for all model years?
NHTSA lists 24 recall campaigns for the Fleetwood American Eagle, model years 1991 to 2011. 4 of them name the 2001 model year.
Which component do the complaints about the 2001 Fleetwood American Eagle name most often?
Service Brakes, Hydraulic: 1 of 2 component mentions.
Is an NHTSA investigation of the 2001 Fleetwood American Eagle open?
The NHTSA investigation file has no investigation that names this model year.