Recall Register

Food, drugs, devices › PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.

Device recall: Philips Azurion 7M20 systems with FlexArm ceiling-mounted system. Model Number: 722234;

FDA enforcement event 97719 · Class II · initiated 2 Oct 2025 · status Ongoing

DeviceVoluntary: Firm initiated1 product recordBest, N/A

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. (Best, N/A) initiated this device recall on 2 Oct 2025; FDA lists 1 product record under event 97719, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 85% of the 945 device enforcement events initiated in 2025 carry the same class.

Status: Ongoing. Initiation: voluntary: firm initiated. PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. has 59 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V., Best, N/A, Netherlands.

Reason for recall

"The motorized longitudinal movement of the FlexArm stand may be inconsistent (not smooth) and eventually may become unavailable. This issue is due to grease leakage from the bearings and/or anti-corrosion oil applied on the bearings, because of which the lubrication on the ceiling rail may be excessive, reducing the friction between the rails and the friction wheel. Expansion to add additional…"

Distribution

"Domestic: AL, AR, AZ, CA, CO, FL, GA, HI, IL, IN, KS, KY, MD, MN, MO, NM, NY, OH, OK, PA, RI, TX, UT, VA, WA, WI, WV, WY; International: Australia, Austria, Belgium, Bulgaria, Canada, Czech…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-0719-2026Philips Azurion 7M20 systems with FlexArm ceiling-mounted system. Model Number: 722234;172 unitsClass IIOngoing3 Dec 2025

Context

85%of 2025 device events are Class II945 events that year
1product record in this eventfirm median: 1
59events on this register for the firm

Other enforcement events for PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.

InitiatedProduct (first record)TypeClassRecords
16 Jul 2026Philips Azurion Rystem, Model Numbers: 722063, 722064, 722067, 722068, 722078, 722079, 722221, 722222,722223, 722224, 72DeviceClass II1
16 Jul 2026Philips Azurion, Model Numbers: 722229, 722230, 722231, 722232, 722233, 722234, 722235, and 722236, with Software VersioDeviceClass II1
29 Jun 2026Allura Xper FD. Model Numbers: 722026, 722027, 722028, 722029, 722035, 722038, 722039, 722058. Interventional fluoroscopDeviceClass II1
17 Jun 2026Philips Allura under the following System Descriptions and corresponding model numbers: 1. Allura Xper FD10; Model NumbeDeviceClass II3
18 May 2026Philips MultiDiagnost Eleva with the following Model Numbers: Model # 708032 for MultiDiagnost Eleva; Model # 708034 forDeviceClass II2
30 Apr 2026Azurion system; System Code Description (Model Numbers): Azurion 3 M12 (722063, 722221), Azurion 3 M15 (722064, 722222),DeviceClass II2
28 Apr 2026Philips Azurion systems not configured with an optional auxiliary pan handle. Includes the below product descriptions anDeviceClass II1
28 Apr 2026Azurion system; System Code Description (Model Numbers): Azurion 3 M12 (722063), Azurion 3 M15 (722064), Azurion 7 B12 (DeviceClass II3
31 Mar 2026Philips Azurion. System Code Description (Model Number): Azurion 3 M12 (722221, 722229), Azurion 3 M15 (722222, 722230),DeviceClass II1
19 Mar 2026Philips AneurysmFlow. Model Number: 001015. AneurysmFlow is a software medical device (Interventional Tool) intended to DeviceClass II1

All 59 events for PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "The motorized longitudinal movement of the FlexArm stand may be inconsistent (not smooth) and eventually may become unavailable. This issue is due to grease leakage from the bearings and/or anti-corrosion oil applied on the bearings, because of which the lubrication on the ceiling rail may be excessive, reducing the friction between the rails and the friction wheel. Expansion to add additional…"

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Domestic: AL, AR, AZ, CA, CO, FL, GA, HI, IL, IN, KS, KY, MD, MN, MO, NM, NY, OH, OK, PA, RI, TX, UT, VA, WA, WI, WV, WY; International: Australia, Austria, Belgium, Bulgaria, Canada, Czech…"

Is the recall still ongoing?

FDA lists the status as Ongoing. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.