Food, drugs, devices › PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.

Device recall: Azurion system; System Code Description (Model Numbers): Azurion 3 M12 (722063), Azurion 3 M15 (722064), Azurion 7 B12 (

FDA enforcement event 98801 · Class II · initiated 28 Apr 2026 · status Ongoing

DeviceVoluntary: Firm initiated3 product records

FDA enforcement event 98801 is a device recall by PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. of Best, initiated 28 Apr 2026 and classified Class II, with 3 product records.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 87% of the 572 device enforcement events initiated in 2026 carry the same class.

Status: Ongoing. Initiation: voluntary: firm initiated. PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. has 59 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V., Best, Netherlands.

Reason for recall

"The deaeration hose in X-ray tube cooling units type CU3101, manufactured between February 2016 and May 2020, may degrade over time, potentially resulting in oil leakage. Oil leakage may affect the cooling performance of the X-ray tube. When the oil flow drops below a certain threshold, the system automatically switches to low-dose fluoroscopy and displays the message Low load fluoroscopy flavor…"

Distribution

"Domestic: Nationwide; International: Canada, Algeria, Argentina, Australia, Austria, Bahrain, Bangladesh, Belarus, Belgium, Bolivia, Bosnia and Herzegovina, Brazil, Brunei Darussalam, Bulgaria,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-2227-2026Azurion system; System Code Description (Model Numbers): Azurion 3 M12 (722063), Azurion 3 M15 (722064), Azurion 7 B12 (722067), Azurion 7 B20 (722068), Azurion 7 M12 (722078), Azurion 7 M20 (722079, 722224).1651 units (592 US, 1359 OUS)Class IIOngoing27 May 2026
Z-2228-2026Allura system; System Code Description (Model Numbers): Allura Xper FD10C (722001), Allura Xper FD10F (722002), Allura Xper FD10 (722003, 722010, 722026), Allura Xper FD10/10 (722005, 722011, 722027), Allura Xper FD20 (722006, 722012, 722028), Allura Xper FD20 Biplane (722008, 722013), Allura Xper FD20 OR Table…3314 units (816 US, 2498 OUS)Class IIOngoing27 May 2026
Z-2229-2026Integris-Allura system; System Code Description (Model Numbers): Integris CV Cesar-Powerpack-Visub-Nicol (722030), Integris Allura 15 & 12 (monoplane) (722043), INTEGRIS Allura 15-12 (biplane) (722044), Integris-Allura 9 (722018), Integris-Allura 9 (Biplane) (722021), Integris CV Cesar-Powerpack (722030), Integris…25 units (11 US, 14 OUS)Class IIOngoing27 May 2026

Context

87%of 2026 device events are Class II572 events that year
3product records in this eventfirm median: 1
59events on this register for the firm

Other enforcement events for PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.

InitiatedProduct (first record)TypeClassRecords
16 Jul 2026Philips Azurion Rystem, Model Numbers: 722063, 722064, 722067, 722068, 722078, 722079, 722221, 722222,722223, 722224, 72DeviceClass II1
16 Jul 2026Philips Azurion, Model Numbers: 722229, 722230, 722231, 722232, 722233, 722234, 722235, and 722236, with Software VersioDeviceClass II1
29 Jun 2026Allura Xper FD. Model Numbers: 722026, 722027, 722028, 722029, 722035, 722038, 722039, 722058. Interventional fluoroscopDeviceClass II1
17 Jun 2026Philips Allura under the following System Descriptions and corresponding model numbers: 1. Allura Xper FD10; Model NumbeDeviceClass II3
18 May 2026Philips MultiDiagnost Eleva with the following Model Numbers: Model # 708032 for MultiDiagnost Eleva; Model # 708034 forDeviceClass II2
30 Apr 2026Azurion system; System Code Description (Model Numbers): Azurion 3 M12 (722063, 722221), Azurion 3 M15 (722064, 722222),DeviceClass II2
28 Apr 2026Philips Azurion systems not configured with an optional auxiliary pan handle. Includes the below product descriptions anDeviceClass II1
31 Mar 2026Philips Azurion. System Code Description (Model Number): Azurion 3 M12 (722221, 722229), Azurion 3 M15 (722222, 722230),DeviceClass II1
19 Mar 2026Philips AneurysmFlow. Model Number: 001015. AneurysmFlow is a software medical device (Interventional Tool) intended to DeviceClass II1
5 Mar 2026Vue Motion V12. Product Number: 1017979.DeviceClass II1

All 59 events for PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "The deaeration hose in X-ray tube cooling units type CU3101, manufactured between February 2016 and May 2020, may degrade over time, potentially resulting in oil leakage. Oil leakage may affect the cooling performance of the X-ray tube. When the oil flow drops below a certain threshold, the system automatically switches to low-dose fluoroscopy and displays the message Low load fluoroscopy flavor…"

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Domestic: Nationwide; International: Canada, Algeria, Argentina, Australia, Austria, Bahrain, Bangladesh, Belarus, Belgium, Bolivia, Bosnia and Herzegovina, Brazil, Brunei Darussalam, Bulgaria,…"

Is the recall still ongoing?

FDA lists the status as Ongoing. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.