Recall Register

Food, drugs, devices › Philips Medical Systems (Cleveland) Inc

Device recall: Brilliance Big Bore Radiology 728244

FDA enforcement event 80176 · Class II · initiated 28 Mar 2018 · status Terminated · terminated 21 Apr 2020

DeviceVoluntary: Firm initiated5 product recordsCleveland, OH

FDA enforcement event 80176 is a device recall by Philips Medical Systems (Cleveland) Inc of Cleveland, OH, initiated 28 Mar 2018 and classified Class II, with 5 product records.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 92% of the 1,074 device enforcement events initiated in 2018 carry the same class.

Status: Terminated, terminated 21 Apr 2020. Initiation: voluntary: firm initiated. Philips Medical Systems (Cleveland) Inc has 129 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Philips Medical Systems (Cleveland) Inc, Cleveland, OH.

Reason for recall

"A problem has been detected in the X-Ray Tube. The affected tubes have a production defect that allows oil leakage from the tube housing, if it were to re-occur, could pose a risk for patients or users."

Distribution

"The systems were distributed to the following US states: HI, KS, and MO. The systems were distributed to the following foreign countries: Algeria, Austria, Brazil, China, Indonesia, Japan, Kenya,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-2273-2018Brilliance Big Bore Radiology 72824428 totalClass IITerminated4 Jul 2018
Z-2274-2018Philips Ingenuity Core 72832128 totalClass IITerminated4 Jul 2018
Z-2275-2018Ingenuity Core128 72832328 totalClass IITerminated4 Jul 2018
Z-2276-2018Ingenuity TF PET/CT 88244228 totalClass IITerminated4 Jul 2018
Z-2277-2018Ingenuity Core128/Elite China 728324—Class IITerminated4 Jul 2018

Context

92%of 2018 device events are Class II1,074 events that year
5product records in this eventfirm median: 1
129events on this register for the firm

Other enforcement events for Philips Medical Systems (Cleveland) Inc

InitiatedProduct (first record)TypeClassRecords
5 Aug 2025Pinnacle Radiation Therapy Planning System: Multimodality Simulation Workspace 18.0.5 Model 870258 UDI code: (01)0088483DeviceClass II1
17 Jul 2025Pinnacle 3 with TumorLOC, (870258) Radiation Therapy Planning System SoftwareDeviceClass II1
30 Aug 2022Pinnacle3 Radiation Therapy Planning System, Model numbers 870231 and 870237.DeviceClass II1
19 Sep 2019Forte Gamma Camera System is intended to produce images depicting the anatomical distribution of single-photon and positDeviceClass I5
24 Jun 2019Ingenuity CT, Model # 728326, computed tomography x-ray systemDeviceClass II9
10 Jun 2019BrightView SPECT, Model Number 882480DeviceClass II3
3 Jun 2019Vereos PET/CT, Model No. 882446 Product Usage: Positron Emission Tomography (PET) and X-ray Computed Tomography (CT) sysDeviceClass II1
19 Dec 2018Ingenuity TF PET/CT (non-RoHS), Model Number 882456 This device is a diagnostic imaging system that combines Positron EmDeviceClass II1
18 Oct 2018Brilliance 64, Model 728231 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images DeviceClass II6
4 Sep 2018Vereos PET/CT, Software version 2.0.1. Model Number: 882446 Product Usage: The Philips Vereos PET/CT system is a diagnosDeviceClass II1

All 129 events for Philips Medical Systems (Cleveland) Inc

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "A problem has been detected in the X-Ray Tube. The affected tubes have a production defect that allows oil leakage from the tube housing, if it were to re-occur, could pose a risk for patients or users."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "The systems were distributed to the following US states: HI, KS, and MO. The systems were distributed to the following foreign countries: Algeria, Austria, Brazil, China, Indonesia, Japan, Kenya,…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 21 Apr 2020. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.