Recall Register

Food, drugs, devices › Stryker Instruments Div. of Stryker Corporation

Device recall: Neptune 2 Waste Management System Docking Station (120V and 230V), New and Refurbished Product Usage: The Stryker Dockin

FDA enforcement event 71872 · Class II · initiated 20 Jul 2015 · status Terminated · terminated 7 Nov 2016

DeviceVoluntary: Firm initiated1 product recordPortage, MI

Stryker Instruments Div. of Stryker Corporation (Portage, MI) initiated this device recall on 20 Jul 2015; FDA lists 1 product record under event 71872, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 91% of the 1,153 device enforcement events initiated in 2015 carry the same class.

Status: Terminated, terminated 7 Nov 2016. Initiation: voluntary: firm initiated. Stryker Instruments Div. of Stryker Corporation has 55 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Stryker Instruments Div. of Stryker Corporation, Portage, MI.

Reason for recall

"The Fluid Coupling Sleeve, a component within the Neptune Waste Management System Docker, may be out of specification. This can cut or dislodge the PTFE seal and cause a leak between the Rover and Docker couplers during docking or leaking from the Rover coupler after docking. The potential hazard is waste fluid and/or fresh water dispensed from the Neptune 2 Rover at the incorrect time."

Distribution

"Worldwide Distribution - US Nationwide in the states of: AL, AZ, CA, CO, CT, DE, FL, GA, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MT, NC, NE, NJ, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-2524-2015Neptune 2 Waste Management System Docking Station (120V and 230V), New and Refurbished Product Usage: The Stryker Docking Station (Docker) is a component of the Neptune 2 Waste Management System. The Stryker Rover, another component of the system, is a mobile unit used to suction and collect fluid waste and surgical…524, 237 of these are non-conformingClass IITerminated9 Sep 2015

Context

91%of 2015 device events are Class II1,153 events that year
1product record in this eventfirm median: 1
55events on this register for the firm

Other enforcement events for Stryker Instruments Div. of Stryker Corporation

InitiatedProduct (first record)TypeClassRecords
15 Jun 2022SurgiCount+ System Application, Software Version 2.0.17, Catalog Number 0694-002-090. Used for counting, displaying, recDeviceClass II1
16 Oct 2020Stryker Zyphr Disposable Cranial Perforator, Large 14/11 mm- is a sterile, single use cutting accessory intended for cutDeviceClass II1
26 Mar 2020Neptune E-SEP 165mm Blade Electrode, Catalog Number 0703-165-001 - Product Usage: The Neptune E-SEP is an Integrated SmoDeviceClass II1
22 Jan 2020Triton Canister System (finished part numbers FG 12009, for 3L canisters, and FG 12019 for 2L canisters) Scanning Label DeviceClass II1
13 Jan 2020SafeAir Telescopic Smoke Evacuation Pencil, Product No. 0703 046 004. The product is a Bovie pencil that is 75 inches loDeviceClass II3
6 Nov 2019Color Cuff Disposable Tourniquet Cuff, 18 inch X 3 inch, 1BLA (Single Bladder), 1PRT(Single Port) Quick Connect ConnectoDeviceClass II2
31 Jul 2019C2 Nerve Monitor, 4 Channel, 5140-508-240, UDI 07613327177329 Product Usage: The C2 Nerve Monitor System is intended forDeviceClass II2
19 Mar 2019Performance Series Sagittal Blade, Catalog Number 6125-127-100 Product Usage: The Stryker Heavy Duty Sagittal Blades areDeviceClass II1
4 Dec 2018Triton Sponge System (Software), GAUS-3, Software Versions 4.6.5, 4.8.7, 4.9.6DeviceClass III1
23 Feb 2018T4 Pullover Toga, (S/M); Catalog Number: 0400-710-000 Sterile personal protection garmentDeviceClass II11

All 55 events for Stryker Instruments Div. of Stryker Corporation

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "The Fluid Coupling Sleeve, a component within the Neptune Waste Management System Docker, may be out of specification. This can cut or dislodge the PTFE seal and cause a leak between the Rover and Docker couplers during docking or leaking from the Rover coupler after docking. The potential hazard is waste fluid and/or fresh water dispensed from the Neptune 2 Rover at the incorrect time."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution - US Nationwide in the states of: AL, AZ, CA, CO, CT, DE, FL, GA, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MT, NC, NE, NJ, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN,…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 7 Nov 2016. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.