Device recall: Stryker Zyphr Disposable Cranial Perforator, Large 14/11 mm- is a sterile, single use cutting accessory intended for cut

FDA enforcement event 86670 · Class II · initiated 16 Oct 2020 · status Terminated · terminated 22 Jun 2022

DeviceVoluntary: Firm initiated1 product recordPortage, MI

Stryker Instruments Div. of Stryker Corporation (Portage, MI) initiated this device recall on 16 Oct 2020; FDA lists 1 product record under event 86670, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 93% of the 916 device enforcement events initiated in 2020 carry the same class.

Status: Terminated, terminated 22 Jun 2022. Initiation: voluntary: firm initiated. Stryker Instruments Div. of Stryker Corporation has 55 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Stryker Instruments Div. of Stryker Corporation, Portage, MI.

Reason for recall

"Potential for the inner bit to contain a crack, that may or may not be visible, which may lead to metal fragments entering the surgical site and/or delayed disengagment during use."

Distribution

"Nationwide Foreign: Australia Brazil Canada Chile Colombia Hong Kong Italy Mexico Netherlands Netherlands New Zealand South Africa South Korea Spain Sweden Switzerland United Kingdom"

Product records

Recall numberProductQuantityClassStatusReport date
Z-0431-2021Stryker Zyphr Disposable Cranial Perforator, Large 14/11 mm- is a sterile, single use cutting accessory intended for cutting an 11 mm diameter access hole through the cranium of adult patients. Catalog Number: 5100-060-00118,492 devices. Expanded Recall total: 18,594 devicesClass IITerminated18 Nov 2020

Context

93%of 2020 device events are Class II916 events that year
1product record in this eventfirm median: 1
55events on this register for the firm

Other enforcement events for Stryker Instruments Div. of Stryker Corporation

InitiatedProduct (first record)TypeClassRecords
15 Jun 2022SurgiCount+ System Application, Software Version 2.0.17, Catalog Number 0694-002-090. Used for counting, displaying, recDeviceClass II1
26 Mar 2020Neptune E-SEP 165mm Blade Electrode, Catalog Number 0703-165-001 - Product Usage: The Neptune E-SEP is an Integrated SmoDeviceClass II1
22 Jan 2020Triton Canister System (finished part numbers FG 12009, for 3L canisters, and FG 12019 for 2L canisters) Scanning Label DeviceClass II1
13 Jan 2020SafeAir Telescopic Smoke Evacuation Pencil, Product No. 0703 046 004. The product is a Bovie pencil that is 75 inches loDeviceClass II3
6 Nov 2019Color Cuff Disposable Tourniquet Cuff, 18 inch X 3 inch, 1BLA (Single Bladder), 1PRT(Single Port) Quick Connect ConnectoDeviceClass II2
31 Jul 2019C2 Nerve Monitor, 4 Channel, 5140-508-240, UDI 07613327177329 Product Usage: The C2 Nerve Monitor System is intended forDeviceClass II2
19 Mar 2019Performance Series Sagittal Blade, Catalog Number 6125-127-100 Product Usage: The Stryker Heavy Duty Sagittal Blades areDeviceClass II1
4 Dec 2018Triton Sponge System (Software), GAUS-3, Software Versions 4.6.5, 4.8.7, 4.9.6DeviceClass III1
23 Feb 2018T4 Pullover Toga, (S/M); Catalog Number: 0400-710-000 Sterile personal protection garmentDeviceClass II11
9 Nov 2017Break-Away Femoral Nozzle, Product Number: 0206-512-000, UDI: (01)4546540039415 for orthopedic use.DeviceClass II13

All 55 events for Stryker Instruments Div. of Stryker Corporation

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Potential for the inner bit to contain a crack, that may or may not be visible, which may lead to metal fragments entering the surgical site and/or delayed disengagment during use."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Nationwide Foreign: Australia Brazil Canada Chile Colombia Hong Kong Italy Mexico Netherlands Netherlands New Zealand South Africa South Korea Spain Sweden Switzerland United Kingdom"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 22 Jun 2022. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.