Device recall: Breathing circuit set, coaxial: REF: 260127, 260128, 260167, 260168 used with HAMILTON-C1, HAMILTON-T1 and HAMILTON-MR1

FDA enforcement event 99028 · Class I · initiated 29 May 2026 · status Ongoing

DeviceVoluntary: Firm initiated1 product recordDomat/Ems, N/A

FDA enforcement event 99028 is a device recall by Hamilton Medical AG of Domat/Ems, N/A, initiated 29 May 2026 and classified Class I, with 1 product record.

FDA defines Class I as a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death. 12% of the 572 device enforcement events initiated in 2026 carry the same class.

Status: Ongoing. Initiation: voluntary: firm initiated. Hamilton Medical AG has 12 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Hamilton Medical AG, Domat/Ems, N/A, Switzerland.

Reason for recall

"Ventilator coaxial breathing circuit may have, expiratory valve sets with membranes sticking to valve body, not detectable during pre-operative test, which will result in "exhalation obstructed " alarm, which may result in inadequate ventilation, oxygen desaturation. Advising: Prior to use, test lung action. If alarm occurs, expiratory valve set removal to overcome membrane adhesion or replacement"

Distribution

"US Nationwide distribution including in the states of KS, WA, VT, TX, WI, AR, OH, PA, CA, CO, ID, AZ, ME, MO, MI, IL, OR, VA, FL, NJ, SD, NY, NM, TN, CT, NE, OK, AL, GA, KY, NH, WY, ND, IN, UT, WV,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-2463-2026Breathing circuit set, coaxial: REF: 260127, 260128, 260167, 260168 used with HAMILTON-C1, HAMILTON-T1 and HAMILTON-MR1 ventilators.27,270 pcsClass IOngoing8 Jul 2026

Context

12%of 2026 device events are Class I572 events that year
1product record in this eventfirm median: 1
12events on this register for the firm

Other enforcement events for Hamilton Medical AG

InitiatedProduct (first record)TypeClassRecords
22 May 2026IntelliCuff, Portable automatic cuff pressure controller REF: 951001DeviceClass II1
26 Jun 2025Breathing circuit set, coaxial, 1.80 m, with flow sensor and expiratory valve set, REF: 260128, used with HAMILTON-C1, HDeviceClass I1
3 Jun 2025Hamilton C6 REF 160021 (ESM Board PN 10144626 UDI-DI code: 76300028PN160021ZW Hamilton C6 is a ventilator intended to prDeviceClass I1
15 May 2024Ventilator HAMILTON-C6, PN: 160021DeviceClass I1
14 Mar 2023HAMILTON-C6, REF: 160021DeviceClass II1
22 Sep 2022Hamilton-C6DeviceClass II1
27 Jun 2022HAMILTON-C6 Intensive Care Ventilator, REF: 160021DeviceClass I1
5 Jan 2021HAMILTON-H900 Humidifier, Models: 950001, 950004DeviceClass III1
25 Mar 2019HAMILTON-G5, with software versions less than or equal to 2.60 The HAMILTON-G5/S1 ventilators are designed for intensiveDeviceClass I1
12 Mar 2018Hamilton-C2 Ventilator Unit Intended to provide ventilator support to adults and pediatrics and optionally infants and nDeviceClass II2

All 12 events for Hamilton Medical AG

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Ventilator coaxial breathing circuit may have, expiratory valve sets with membranes sticking to valve body, not detectable during pre-operative test, which will result in "exhalation obstructed " alarm, which may result in inadequate ventilation, oxygen desaturation. Advising: Prior to use, test lung action. If alarm occurs, expiratory valve set removal to overcome membrane adhesion or replacement"

What does Class I mean?

FDA classifies recalls by relative degree of health hazard. Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.

Where was the product distributed?

FDA's distribution pattern field reads: "US Nationwide distribution including in the states of KS, WA, VT, TX, WI, AR, OH, PA, CA, CO, ID, AZ, ME, MO, MI, IL, OR, VA, FL, NJ, SD, NY, NM, TN, CT, NE, OK, AL, GA, KY, NH, WY, ND, IN, UT, WV,…"

Is the recall still ongoing?

FDA lists the status as Ongoing. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.