2014 McNeilus Bridgemaster V Mixer: recalls and complaints
NHTSA lists 6 recall campaigns for the 2014 McNeilus Bridgemaster V Mixer. The newest campaign is 19V656000. NHTSA received the report on 17 Sep 2019. The NHTSA record gives the component Fuel System, Other / Storage / Tank Assembly / Pressure Relief Devices. NHTSA has no complaint on file for this model year.
The NHTSA recall file shows no do-not-drive advisory and no park-outside advisory on these campaigns.
This page cannot show if a recall applies to one vehicle. The NHTSA VIN lookup shows the unrepaired recalls of one vehicle.
Remedy of the newest campaign, 19V656000, in the NHTSA record
McNeilus will notify owners, and dealers will inspect and replace the PRD's, as necessary, free of charge. The recall began October 30, 2019. Owners may contact McNeilus customer service at 1-888-686-7278.
Complaint information entered into NHTSA’s Office of Defects Investigation vehicle owner's complaint database is used with other data sources to identify safety issues that warrant investigation and to determine if a safety-related defect trend exists.
NHTSA publishes these words. Source: NHTSA Datasets and APIs, section Complaints, read on . Complaint file through . Recall file through .
Since the last update
No tracked figure of this page changed in a data update. What the log tracks
Recall campaigns
6 campaigns, newest first. 9,751 units in total.
- 19V656000Fuel System, Other / Storage / Tank Assembly / Pressure Relief Devices
- 18V322000Equipment
- 17V228000Fuel System, Other / Delivery / Hoses, Lines/Piping, and Fittings
- 15V572000Equipment
- 15V111000Parking Brake / Conventional / Air
- 14V135000Equipment
19V656000Received . 330 units.
Fuel System, Other / Storage / Tank Assembly / Pressure Relief Devices
- Defect, in the NHTSA record
McNeilus Truck & Manufacturing, Inc. (McNeilus) is recalling certain 2013-2018 Bridgemaster Mixer, Standard Mixer, Model 49 Autoreach Side Loader, Model 48 Zero Radius Side Loader, Model 78 Meridian Front Loader, Model 29 Atlantic Front Loader, Model 87 Contender Front Loader, Model 42 Manual Automated Side Loader, Model 16 3.5 yard TG Rear Loader, Model 11 Heavy Duty Rear Loader, Model 66 40.60 Split Body Rear Loader, Model 10 Standard Rear Loader, Model 12 Tailgate Tag Axle Rear Loader, and Model 13 High Compaction Rear Loader vehicles. The vehicles are powered with compressed natural gas (CNG) and are equipped with pressure relief devices (PRD) that may not function as designed, failing to vent a buildup of pressure, such as could occur if the CNG tank was exposed to fire.
- Consequence, in the NHTSA record
If the PRD does not activate in the event of a buildup of pressure, the CNG tank may explode, increasing the risk of fire and injury.
- Remedy, in the NHTSA record
McNeilus will notify owners, and dealers will inspect and replace the PRD's, as necessary, free of charge. The recall began October 30, 2019. Owners may contact McNeilus customer service at 1-888-686-7278.
Report filed by McNeilus Truck & Manufacturing, Inc.. Owner notification date in the NHTSA record: .
18V322000Received . 1,669 units.
Equipment
- Defect, in the NHTSA record
McNeilus Truck & Manufacturing, Inc. (McNeilus) is recalling certain 2008-2018 Bridgemaster V concrete mixers equipped with an optional composite material hydraulic tank. The filler neck check valve may seal the tank too tightly, causing the tank to overpressurize and possibly rupture.
- Consequence, in the NHTSA record
If the tank ruptures it may cause hydraulic fluid to spill. The ruptured tank can cause injuries from plastic debris. The spilled hydraulic fluid could be hot which could cause burn injuries. If the vehicle is on the road when the tank ruptures, the tank pieces or spilled hydraulic fluid may cause a road hazard which could increase the risk of a crash.
- Remedy, in the NHTSA record
McNeilus has notified owners, and dealers will replace the filler neck, free of charge. The recall began on June 4, 2018. Owners may contact McNeilus customer service at 1-888-686-7278. McNeilus' number for the recall is VSR-TSB-018.
Report filed by McNeilus Truck & Manufacturing, Inc.. Manufacturer campaign number VSR-TSB-018. Owner notification date in the NHTSA record: .
17V228000Received . 258 units.
Fuel System, Other / Delivery / Hoses, Lines/Piping, and Fittings
- Defect, in the NHTSA record
McNeilus Truck & Manufacturing, Inc. (McNeilus) is recalling certain 2014-2016 Standard (REL-10), Heavy Duty (REL-11), Extra Compaction (XC/REL-13), 3.5 yd Tag Axle (TG/REL-16), Atlantic Front Loader (FEL-29), Zero Radius (ZR/ASL-48), AutoReach (AR/ASL-49), Pacific Ultra Front Loader (FEL-76) and Pacific Full Eject Front Loader (FEL-87) refuse trucks, and Bridgemaster(BMV) and Standard (STD) concrete mixers, equipped with Cummins ISX12G compressed natural gas (CNG) engines. These vehicles may have been built with an incorrect fitting to connect the low pressure CNG hose to the CNG fuel filter.
- Consequence, in the NHTSA record
The incorrect fitting may result in a CNG leak, which in the presence of an ignition source, may increase the risk of a fire. Additionally, the hose may disconnect from the filter and result in an engine stall, increasing the risk of a crash.
- Remedy, in the NHTSA record
McNeilus will notify owners, and pay for the owner's service technicians to install the correct fitting. The recall began on April 28, 2017. Owners may contact McNeilus customer service at 1-888-686-7278. McNeilus' number for this recall is VSR-TSB-017.
Report filed by McNeilus Truck & Manufacturing, Inc.. Manufacturer campaign number VSR-TSB-017. Owner notification date in the NHTSA record: .
15V572000Received . 6,745 units.
Equipment
- Defect, in the NHTSA record
McNeilus Truck & Manufacturing, Inc., (McNelius) is recalling certain model year 2013-2015 McNeilus Bridge Master Mixer, Standard Mixer, Sliding Trailer Mixer, Standard Rear Loader, Rear Loader w/3.5 YD HD Tail, Zero Radius Automated, Auto Reach, Atlantic Front Loader, Split Body Rear Loader, Rear Loader w/Tag Axle, Metro Pak Rear Loader, XXC Rear Loader, and Pacific Front Loader vehicles manufactured August 1, 2013, to May 14, 2015. These concrete mixers and refuse trucks are equipped with certain Kidde plastic valve disposable handheld fire extinguishers that may not properly discharge when the lever is pressed.
- Consequence, in the NHTSA record
In the event of a fire, if the fire extinguisher does not work correctly, there is an increased risk of injury.
- Remedy, in the NHTSA record
McNeilus will notify owners, and advise them to follow the provided instructions from Kidde to inspect their fire extinguishers. Kidde will replace the fire extinguishers as necessary, free of charge. The recall began on October 19, 2015. Owners may contact McNeilus customer service at 1-888-686-7278. McNeilus' number for this recall is Kidde: CPSC 15-079.
Report filed by McNeilus Truck & Manufacturing, Inc.. Manufacturer campaign number Kidde: CPSC 15-079. Owner notification date in the NHTSA record: .
15V111000Received . 536 units.
Parking Brake / Conventional / Air
- Defect, in the NHTSA record
McNeilus Truck & Manufacturing, Inc. (McNeilus) is recalling certain model year 2005-2014 Bridgemaster V Mixer vehicles manufactured October 1, 2005, to December 31, 2014. The affected vehicles are built with the optional Bridgemaster parking brake system on the trailing liftable axle. This parking brake system includes a valve that allows the secondary brake pressure to fall below the required 45 psi after one treadle application. As such, these vehicles fail to comply with Federal Motor Vehicle Safety Standard (FMVSS) No. 121, "Air Brake Systems."
- Consequence, in the NHTSA record
If the primary braking system fails, the emergency brake system may not achieve the level of performance needed, increasing the risk of a crash.
- Remedy, in the NHTSA record
McNeilus will notify owners, and dealers will install a check valve, free of charge. The recall began on March 10, 2015. Owners may contact McNeilus customer service at 1-888-686-7278. McNeilus' number for this recall is VSR-TSB-009.
Report filed by McNeilus Truck & Manufacturing, Inc.. Manufacturer campaign number VSR-TSB-009. Owner notification date in the NHTSA record: .
14V135000Received . 213 units.
Equipment
- Defect, in the NHTSA record
McNeilus Truck & Manufacturing, Inc. (McNeilus) is recalling certain model year 2013-2014 McNeilus Concrete Standard and Bridgemaster V concrete mixers, manufactured October 25, 2013, through February 14, 2014, and equipped with the optional vertical chute rack design. The subject vehicles have extension chutes that can unexpectedly fall out of the rack.
- Consequence, in the NHTSA record
An extension chute that falls from the rack may create a road hazard, increasing the risk of a crash.
- Remedy, in the NHTSA record
McNeilus will notify owners, and dealers will replace the vertical chute rack with a new design, free of charge. Owners may contact Mcneilus at 1-507-374-6321. McNeilus' number for this recall is 41-0967369.
Report filed by McNeilus Truck & Manufacturing, Inc.. Manufacturer campaign number 41-0967369. Owner notification date in the NHTSA record: .
The campaign number opens the NHTSA record. Each quotation is the text of the NHTSA recall file.
Recall campaign: One recall in the NHTSA recall file, with one campaign number. A campaign can name many makes, models and model years.
Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.
Complaints by component
The NHTSA complaint file has no complaint for this model year.
Investigations
The NHTSA investigation file has no investigation that names this model year.
Investigation: A study of a possible safety defect by the NHTSA Office of Defects Investigation. An investigation with no closing date in the NHTSA file is open.
Other model years
The number under each year is the number of recall campaigns.
A year without a link has fewer than 2 campaigns and fewer than 25 complaints. It has no page.
Follow by RSS:McNeilus recallsVehicle recalls
Official channels
- NHTSA VIN lookupNHTSA shows the unrepaired recalls of one vehicle from its VIN or its license plate.
- NHTSA: report a safety problemThe NHTSA form for a complaint about a vehicle, a tire, a child seat or equipment.
- NHTSA page of the 2014 McNeilus Bridgemaster V MixerThe recalls, the complaints and the investigations that NHTSA shows for this model year.
Cite this page
Recall Register. 2014 McNeilus Bridgemaster V Mixer: recalls and complaints. https://recallregister.com/vehicle/mcneilus/bridgemaster-v-mixer/2014/. Source: NHTSA Office of Defects Investigation, recall, complaint and investigation files. Data through .
Sources
- Source
- NHTSA Office of Defects Investigation
- Licence
- US government work, public domain
- Recall file through
- 30 Sep 2026
- Complaint file through
- 29 Mar 2018
- First complaint in the file
- 1 Jan 1995
- Manufacturer in the recall file
- McNeilus Truck & Manufacturing, Inc.
The NHTSA record is the authority. A complaint count is the number of different complaint numbers for the make, the model and the model year. How the register is made. Report an error.
Questions
- How many units are in the recall campaigns for the 2014 McNeilus Bridgemaster V Mixer?
- 9,751 units in 6 campaigns. A campaign can name other models and model years, and its units include them.
- How many recall campaigns does the McNeilus Bridgemaster V Mixer have for all model years?
- NHTSA lists 11 recall campaigns for the McNeilus Bridgemaster V Mixer, model years 2005 to 2020. 6 of them name the 2014 model year.
- Is an NHTSA investigation of the 2014 McNeilus Bridgemaster V Mixer open?
- The NHTSA investigation file has no investigation that names this model year.