Recall Register

2006 Glaval Universal: recalls and complaints

NHTSA lists 13 recall campaigns for the 2006 Glaval Universal. The newest campaign is 14V599000. NHTSA received the report on 26 Sep 2014. The NHTSA record gives the component Equipment Adaptive/Mobility. NHTSA has no complaint on file for this model year.

The NHTSA recall file shows no do-not-drive advisory and no park-outside advisory on these campaigns.

This page cannot show if a recall applies to one vehicle. The NHTSA VIN lookup shows the unrepaired recalls of one vehicle.

Remedy of the newest campaign, 14V599000, in the NHTSA record

Forest River will notify owners to take buses to a Ricon dealer or service center who will install supplemental platform support bumpers. Any platform that has already started cracking will be replaced, free of charge. The recall began on December 1, 2014. Owners may contact Glaval customer service at 1-800-445-2825 or Ricon customer service at 1-800-322-2884.

Complaint information entered into NHTSA’s Office of Defects Investigation vehicle owner's complaint database is used with other data sources to identify safety issues that warrant investigation and to determine if a safety-related defect trend exists.

NHTSA publishes these words. Source: NHTSA Datasets and APIs, section Complaints, read on . Complaint file through . Recall file through .

Since the last update

No tracked figure of this page changed in a data update. What the log tracks

All updates to the register

Recall campaigns

13 campaigns, newest first. 4,344 units in total.

  1. 14V599000Received . 828 units.

    Equipment Adaptive/Mobility

    Defect, in the NHTSA record
    Forest River, Inc. (Forest River) is recalling certain model year 2006-2014 Glaval Universal, Primetime, Sport, Titan, and Titan II transit and shuttle buses manufactured January 1, 2006, to September 26, 2014, and equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured by Ricon. The platform side plate of the affected wheelchair lifts may crack.
    Consequence, in the NHTSA record
    If the platform side plates crack, the lift platform can separate from the lift and come to rest against the vehicle's lift door. When the doors are opened, the platform may fall out, increasing the risk of injury to the lift operator.
    Remedy, in the NHTSA record
    Forest River will notify owners to take buses to a Ricon dealer or service center who will install supplemental platform support bumpers. Any platform that has already started cracking will be replaced, free of charge. The recall began on December 1, 2014. Owners may contact Glaval customer service at 1-800-445-2825 or Ricon customer service at 1-800-322-2884.

    Report filed by Forest River, Inc.. Owner notification date in the NHTSA record: .

  2. 12V321000Received . 381 units.

    Equipment Adaptive/Mobility

    Defect, in the NHTSA record
    Glaval is recalling certain buses equipped with braun century-2 and/or vista-2 wheelchair lifts. Over time and with frequent use, the roll stop latches on the outer barrier may become bent or misaligned.
    Consequence, in the NHTSA record
    A wheelchair occupant may defeat or ride over the insufficiently latched roll stop. If this occurs when the lift platform is in an elevated position, the wheelchair’s occupant could fall and sustain injury.
    Remedy, in the NHTSA record
    Glaval will notify owners, and the repairs will be performed by authorized braun dealers free of charge. Owners may contact glaval bus at 1-800-347-7440.

    Report filed by GLAVAL BUS DIVISION. Owner notification date in the NHTSA record: .

  3. 12V011000Received . 1,407 units.

    Equipment / Appliance / Air Conditioner

    Defect, in the NHTSA record
    Glaval is recalling certain model year 2006 through 2007 transit buses built on ford, GMC, chevrolet, and freightliner chassis and equipped with carrier genv em-1 evaporator units. Due to time, temperature, and/or vibration, the fuse may loosen in the fuse holder resulting in high resistance and arcing.
    Consequence, in the NHTSA record
    If sufficient arcing occurs, the fuse holder may melt, and a vehicle fire may occur.
    Remedy, in the NHTSA record
    Glaval will notify owners and provide information on how to obtain the retrofit kit from carrier along with repair instructions. This service will be performed free of charge. The safety recall began on january 14, 2012. (see carrier's recall campaign 11e-003.) owners may contact carrier at 1-800-348-7440.

    Report filed by GLAVAL BUS DIVISION. Owner notification date in the NHTSA record: .

  4. 10V618000Received . 119 units.

    Equipment

    Defect, in the NHTSA record
    Glaval is recalling certain model year 2002, 2003, 2006, 2007, and 2008 ford e350/e450 universal, chevy/GMC 4500/5500 titan and freightliner mb-55 apollo transit buses manufactured from august 1999 through july 2007, and equipped with a trans/air ta73 evaporator. The evaporator utilizes a power resistor to regulate blower speed. Should a short occur in the "low or medium speed" circuit while the blower is in high speed, the short will cause the supply voltage to feedback through the resistor to ground, not drawing enough current to trip the fuse.
    Consequence, in the NHTSA record
    This would cause the resistor temperature to rise to a point where it will melt and possibly ignite the plastic blower housing to which it is mounted. The overheating can result in a fire.
    Remedy, in the NHTSA record
    Glaval in cooperation with trans air will install a thermal shutdown device in series with the speed resistors. This service will be performed free of charge. The safety recall began on december 23, 2010. Owners may contact trans air warranty and service center at 1-800-673-2446.

    Report filed by GLAVAL BUS DIVISION. Owner notification date in the NHTSA record: .

  5. 10V143000Received . 302 units.

    Equipment Adaptive/Mobility

    Defect, in the NHTSA record
    Glaval bus is recalling certain model year 2006 through 2010 universal, titan, titan II, primetime, sport, and apollo transit buses manufactured between december 2007 and december 2009 fitted with ricon public use lifts. The restraint belt on these lifts was designed to prevent the lift from moving, unless the tongue of the belt is fully engaged and latched in the buckle. Ricon has discovered, however, that it is possible for the operator to insert the belt tongue into the buckle without fully engaging the latching mechanism. In this case, the restraint belt would appear to be latched, and the operator could run the lift. If the restraint belt tongue is not fully engaged into the restraint belt buckle, and latched, the lift may operate with an occupant on the platform.
    Consequence, in the NHTSA record
    The user of the lift could be injured should the lift move without the restraint belt properly buckled.
    Remedy, in the NHTSA record
    Glaval bus is working with ricon and ricon will be performing the remedy for this campaign. Please see ricon's defect report 09e-060. Ricon will provide customers with a warning decal and a dvd-based training aid. The safety recall began on april 26, 2010. Owners may contact ricon at 1-818-267-3000 or glaval bus at 1-800-322-2884.

    Report filed by GLAVAL BUS DIVISION. Owner notification date in the NHTSA record: .

  6. 09V421000Received . 161 units.

    Interior Lighting

    Defect, in the NHTSA record
    Glaval bus is recalling certain model year 2001 through 2009 transit buses equipped with luminator horizon LED side destination signs. The connector board can corrode due to an accumulation of moisture under the connector.
    Consequence, in the NHTSA record
    A short could occur, possibly causing smoke and fire.
    Remedy, in the NHTSA record
    Glaval bus will notify owners and luminator will repair the buses free of charge. Please see luminator's defect report 09e-054. The safety recall began on november 10, 2009. Owners may contact luminator at 1-972-516-3033 or glaval bus at 1-574-262-2212.

    Report filed by GLAVAL BUS DIVISION. Manufacturer campaign number 17744. Owner notification date in the NHTSA record: .

  7. 09V095000Received . 42 units.

    Equipment Adaptive/Mobility

    Defect, in the NHTSA record
    Atlantic bus sales is recalling 42 ricon wheelchair lifts which it installed on certain my 2006 and 2007 eldorado and glaval transit buses. These vehicles fail to comply with the requirements of federal motor vehicle safety standard no. 404, "platform lift installations in motor vehicles." the anti-stow interlock may not detect the presence of a wheelchair or mobility aid user. The pressure sensing switch that detects the presence of weight on the platform was not adjusted to the necessary sensitivity level. The lift could stow even though someone or something is still on the lift.
    Consequence, in the NHTSA record
    The user of the lift could be injured should the lift move unintentionally.
    Remedy, in the NHTSA record
    Atlantic bus sales is working with ricon to correct the wheelchair lifts free of charge (please see 07e097). Owners may contact ricon at 1-818-267-3000 or atlantic bus sales at 1-954-941-7722.

    Report filed by ATLANTIC BUS SALES.

  8. 09V094000Received . 110 units.

    Equipment Adaptive/Mobility

    Defect, in the NHTSA record
    Atlantic bus sales is recalling 110 ricon wheelchair lifts which it installed on my 2006 and 2007 eldorado and glaval transit buses. These vehicles fail to comply with the requirements of federal motor vehicle safety standard no. 404, "platform lift installations in motor vehicles." the threshold warning system may not detect the presence of a wheelchair or mobility aid user in a certain spot within the defined threshold area.
    Consequence, in the NHTSA record
    The user of the lift could be injured should the lift move unintentionally.
    Remedy, in the NHTSA record
    Atlantic bus sales is working with ricon to correct the wheelchair lifts free of charge (please see 07e095). Owners may contact ricon at 1-818-267-3000 or atlantic bus sales at 1-954-941-7722.

    Report filed by ATLANTIC BUS SALES.

  9. 08V493000Received . 171 units.

    Equipment Adaptive/Mobility

    Defect, in the NHTSA record
    Glaval bus is recalling 171my 2005-2006 universal, primetime, titan, and apollo transit and shuttle buses equipped with ricon platform style wheelchair lifts. These lifts fail to comply with the requirements of federal motor vehicle safety standard no. 403, "platform lift systems for motor vehicles." the anti-stow interlock may not detect the presence of a wheelchair or mobility aid user. The pressure sensing switch that detects the presence of weight on the platform was not adjusted to the necessary sensitivity level. The lift could stow even though someone or something is still on the lift.
    Consequence, in the NHTSA record
    A lift occupant can be injured should the lift begin to stow unintentionally.
    Remedy, in the NHTSA record
    Glaval bus is working with ricon to correct the wheelchair lifts (please see 07e097). Owners may contact ricon at 1-800-322-2884 or glaval bus at 1-574-262-2212.

    Report filed by GLAVAL BUS DIVISION.

  10. 08V014000Received . 215 units.

    Equipment Adaptive/Mobility

    Defect, in the NHTSA record
    Certain transit buses equipped with braun platform lifts fail to comply with the requirements of federal motor vehicle safety standard no. 404, "platform lift installations in motor vehicles." a passenger can approach the exposed lift doorway without the audible alarm alerting them of their proximity to the threshold.
    Consequence, in the NHTSA record
    Should the threshold warning system fail to operate, the lift user can fall from the vehicle and be seriously injured.
    Remedy, in the NHTSA record
    Glaval is working with braun corporation to have the doorway lift fixed free of charge (please see 06e094). Owners may contact braun corporation at 1-800-946-7513 or glaval at 1-574-262-2212.

    Report filed by GLAVAL BUS DIVISION.

  11. 07V072000Received . 75 units.

    Equipment Adaptive/Mobility

    Defect, in the NHTSA record
    Certain buses equipped with ricon platform style wheelchair lifts fail to comply with the requirements of federal motor vehicle safety standard no. 403, "platform lift systems for motor vehicles." the inner barrier interlock switch system in the lift baseplate may not detect the presence of a passenger (either wheelchair or standee) on the barrier and can allow the platform to move down more than one inch below floor level when occupied.
    Consequence, in the NHTSA record
    In the event this condition occurs during passenger operations, it may be possible for the wheelchair to tip backwards onto the platform if the user is backing onto the lift from inside the vehicle and has the small front wheels fully or partially on the inner barrier when the platform was lowered. A person standing could lose his or her balance if they were positioned fully or partly on the inner barrier when the platform was lowered. Either condition could cause personal injury.
    Remedy, in the NHTSA record
    Glaval bus is working with ricon to repair these wheelchair lifts (please see 06e101). Owners can contact ricon at 800-322-2884 or glaval bus at 574-262-2212.

    Report filed by GLAVAL BUS DIVISION. Owner notification date in the NHTSA record: .

  12. 06V304000Received . 356 units.

    Seats

    Defect, in the NHTSA record
    Certain transit buses, built on ford, freightliner, and general motors chassis, fail to comply with the requirements of federal motor vehicle safety standard no. 210, 'seat belt assembly anchorages.' the seats equipped with seat belts may have been bolted to the bus structure incorrectly.
    Consequence, in the NHTSA record
    An occupant not properly wearing a seat belt may have an increased risk of injury during a crash.
    Remedy, in the NHTSA record
    Dealers will install the necessary parts to correctly fasten the seats to the bus structure free of charge. The recall began on august 25, 2006. Owners may contact glaval bus at 1-800-445-2824.

    Report filed by GLAVAL BUS DIVISION. Owner notification date in the NHTSA record: .

  13. 06V071000Received . 177 units.

    Seats

    Defect, in the NHTSA record
    On certain buses equipped with seat belts, the t-nut which holds the seat leg to the floor track is missing machined bevels.
    Consequence, in the NHTSA record
    In the event of a crash, without the bevels, the sharp edge could come through the floor track increasing the risk of injury to seat occupant.
    Remedy, in the NHTSA record
    Owners will be provided with the necessary parts to replace the t-nuts free of charge. The recall began on march 24, 2006. Owners may contact glaval bus at 1-800-445-2825.

    Report filed by GLAVAL BUS DIVISION. Owner notification date in the NHTSA record: .

The campaign number opens the NHTSA record. Each quotation is the text of the NHTSA recall file.

Recall campaign: One recall in the NHTSA recall file, with one campaign number. A campaign can name many makes, models and model years.

Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.

Complaints by component

The NHTSA complaint file has no complaint for this model year.

Investigations

The NHTSA investigation file has no investigation that names this model year.

Investigation: A study of a possible safety defect by the NHTSA Office of Defects Investigation. An investigation with no closing date in the NHTSA file is open.

Other model years

The number under each year is the number of recall campaigns.

  1. 19901
  2. 19911
  3. 19991
  4. 20001
  5. 20012
  6. 20024
  7. 20034
  8. 20042
  9. 20055
  10. 200613
  11. 200712
  12. 200811
  13. 200911
  14. 201011
  15. 20119
  16. 20126
  17. 20133
  18. 20141

A year without a link has fewer than 2 campaigns and fewer than 25 complaints. It has no page.

Official channels

Cite this page

Recall Register. 2006 Glaval Universal: recalls and complaints. https://recallregister.com/vehicle/glaval/universal/2006/. Source: NHTSA Office of Defects Investigation, recall, complaint and investigation files. Data through .

Sources

Source
NHTSA Office of Defects Investigation
Licence
US government work, public domain
Recall file through
29 Sep 2026
Complaint file through
15 May 2019
First complaint in the file
1 Jan 1995
Manufacturer in the recall file
Forest River, Inc.

The NHTSA record is the authority. A complaint count is the number of different complaint numbers for the make, the model and the model year. How the register is made. Report an error.

Questions

How many units are in the recall campaigns for the 2006 Glaval Universal?
4,344 units in 13 campaigns. A campaign can name other models and model years, and its units include them.
How many recall campaigns does the Glaval Universal have for all model years?
NHTSA lists 29 recall campaigns for the Glaval Universal, model years 1990 to 2014. 13 of them name the 2006 model year.
Is an NHTSA investigation of the 2006 Glaval Universal open?
The NHTSA investigation file has no investigation that names this model year.