Recall Register

Global Industrial Recalls Workbench Components Due To Electrical Shock Hazard

CPSC recall 11724. Recall date: . Last publish date of the CPSC notice: .

Hazard, in the words of CPSC

Misrouted wiring in the electrical outlets on the workbench risers, aprons and shelves, and reverse polarity in some workbench power cords pose an electric shock hazard.

Remedy, in the words of CPSC

Consumers should immediately unplug their workbench power cords and stop using the electrical outlets on the workbenches. Additionally, they should remove the power cord from the workbench. Global is contacting its customers directly and either sending replacement risers, aprons and shelves with properly wired outlets and replacement power cords or sending technicians on-site to repair faulty wiring and replace faulty power cords.

CPSC recall 11724 has the recall date 9 Mar 2011. The notice names the firm Global Equipment Company, of Port Washington, N.Y., dba Global Industrial. The recall has about 5,000 units. The median CPSC recall of 2011 has 12,000 units. This register puts the recall under the hazard Electric shock. CPSC gives the product type Workshop Furnishings.

Federal law prohibits any person from selling products subject to a Commission ordered recall or a voluntary recall undertaken in consultation with the CPSC.

CPSC publishes these words. Source: CPSC recall notices, section About the U.S. CPSC, read on . The hazard, the remedy and the incident text on this site are the words of the CPSC recall notice. Newest CPSC recall on the register: .

More of the notice

The hazard and the remedy are at the top of the page. Each quotation is the text of CPSC.

CPSC recall 11724: incidents, units, products and firms
Incidents and injuries
Global has received eight reports of misrouted wires.
Units5,000
Remedy optionsRepair
Description
This recall affects all workbenches with the following components: - The Power Riser is made of steel, has an 18-inch shelf with four duplex receptacles and an on/off switch mounted along the front. It comes in gray only and in lengths of 60, 72 and 96 inches. The riser attaches to the top of the bench. - The Power Apron is made of steel, has three duplex receptacles and an on/off switch mounted in one of the long cross beams. It comes in blue or tan and in lengths of 48, 60, 72 and 96 inches. - The Power Shelf is made of steel, has three duplex receptacles and an on/off switch mounted on the front. It comes in blue or tan and in lengths of 48, 60, 72 and 96 inches. It attaches to a pair of 48-inch uprights.
ProductGlobal Workbench Power Risers, Power Aprons and Power Shelves, About 5,000, Workshop Furnishings
Sold atGlobal Industrial sold the workbench components through its catalogs and on the Internet, from January 9, 2009 to December 24, 2010 for approximately $85 to $516.
ManufacturerGlobal Equipment Company, of Port Washington, N.Y., dba Global Industrial
Made inChina

Recall notice: The page that CPSC publishes for one recall of a consumer product. It states the product, the hazard, the remedy and the incidents.

Hazard: The way a product can cause harm, in the words of the CPSC recall notice. This site also puts each recall under short hazard names.

Remedy: What the manufacturer or the firm does about a recalled product. The agency record states the remedy of each recall.

Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.

The recall in context

Units in this recall
5,000Median of 2011: 12,000
CPSC recalls of 2011
313
Recalls of 2011 with one of the same hazards
4%
Recalls of 2011 in the category Workshop Furnishings
0%
Recalls on the register that name Global Equipment Company, of Port Washington, N.Y., dba Global Industrial
1

Official channels

Cite this page

Recall Register. CPSC recall 11724. https://recallregister.com/product/835-global-industrial-recalls-workbench-components-due-to-electrical-shock/. Source: CPSC Recall Retrieval Web Services. Data through .

Sources

Source
US Consumer Product Safety Commission
Licence
US government work, public domain
Data retrieved
30 Sep 2026
Newest CPSC recall on the register
24 Sep 2026

The CPSC notice is the authority. The hazard names come from the hazard text of CPSC. The category is the product type that CPSC gives. How the register is made. Report an error.

Questions

Does CPSC recall 11724 report injuries?
The CPSC notice says: Global has received eight reports of misrouted wires.
Where was the product sold?
The CPSC notice says: Global Industrial sold the workbench components through its catalogs and on the Internet, from January 9, 2009 to December 24, 2010 for approximately $85 to $516.
Which remedy options does CPSC list for recall 11724?
CPSC lists 1 remedy option: Repair
How many units are in CPSC recall 11724?
The CPSC notice gives this number: About 5,000