Recall Register

General Electric Recalls Dishwashers Due to Fire Hazard

CPSC recall 07190. Recall date: . Last publish date of the CPSC notice: .

Hazard, in the words of CPSC

Liquid rinse-aid can leak from its dispenser onto the dishwasher's internal wiring, which can cause an electrical short and overheating, posing a fire hazard to consumers.

Remedy, in the words of CPSC

Consumers should immediately stop using the recalled dishwashers and contact General Electric for a free repair, a $150 rebate towards the purchase of a new GE dishwasher, or a $300 rebate towards the purchase of a new GE Profile or GE Monogram dishwasher.

CPSC recall 07190 has the recall date 16 May 2007. The notice names the firm GE Consumer & Industrial. The recall has about 2,500,000 units. The median CPSC recall of 2007 has 14,000 units. This register puts the recall under 2 hazards. The first is Fire. CPSC gives the product type Dishwashers.

Federal law prohibits any person from selling products subject to a Commission ordered recall or a voluntary recall undertaken in consultation with the CPSC.

CPSC publishes these words. Source: CPSC recall notices, section About the U.S. CPSC, read on . The hazard, the remedy and the incident text on this site are the words of the CPSC recall notice. Newest CPSC recall on the register: .

More of the notice

The hazard and the remedy are at the top of the page. Each quotation is the text of CPSC.

CPSC recall 07190: incidents, units, products and firms
Incidents and injuries
GE has received 191 reports of overheated wiring, including 56 reports of property damage. There were 12 reports of fires that escaped the dishwasher. Fire damage was limited to the dishwasher or the adjacent area. No injuries have been reported.
Units2,500,000
Description
The recall includes GE built-in dishwashers sold under the following brand names: Eterna, GE, GE Profile™, GE Monogram®, Hotpoint®, and Sears-Kenmore. The dishwashers were sold in white, black, almond, bisque and stainless steel. The brand name is printed on the dishwasher's front control panel. The following model and serial numbers can be found inside the dishwasher tub on the front left side of the dishwasher. Brand Model Numbers Must Begin With Serial Numbers Must Begin With Eterna EDW20, EDW30 SS, TS, VS, ZS, AT, DT, FT, GT, HT, LT, MT, RT, ST, TT, VT, ZT, AV, DV, FV, GV, HV, LV, MV, RV, SV, TV, VV, ZV, AZ, DZ, FZ, GZ, HZ, LZ, MZ, RZ, SZ, TZ, VZ, ZZ, AA, DA, FA, GA, HA, LA, MA, RA, SA, TA, VA, ZA GE and GE Profile GHD50, GSD40, GSD41, GSD43, GSD46, GSD4910Z, GSD4920Z, GSD4930Z, GSD4940Z0, GSD50, GSD51, GSD521, GSD522, GSD523, GSD531, GSD532, GSD533, GSD535, GSD536, GSD55, GSD56, GSD57, GSD58, GSD59, GSDL3, GSDL6 GE Monogram ZBD3500Z0 Hotpoint HDA3400F, HDA35 SS, TS, VS, ZS, AT, DT, FT, GT, HT, LT, MT, RT, ST, TT, VT, ZT, AV, DV, FV, GV, HV, LV, MV, RV, SV, TV, VV, ZV, AZ, DZ, FZ, GZ, HZ, LZ, MZ, RZ, SZ, TZ, VZ, ZZ GE and GE Profile GHD35, GSD21, GSD2200D, GSD2200F, GSD2200G,…
ProductGE Dishwashers, About 2.5 million, Dishwashers
Sold atDepartment and appliance stores from September 1997 through December 2001 for about $400.
ManufacturerGE Consumer & Industrial
Made inUnited States

Recall notice: The page that CPSC publishes for one recall of a consumer product. It states the product, the hazard, the remedy and the incidents.

Hazard: The way a product can cause harm, in the words of the CPSC recall notice. This site also puts each recall under short hazard names.

Remedy: What the manufacturer or the firm does about a recalled product. The agency record states the remedy of each recall.

Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.

The recall in context

Units in this recall
2,500,000Median of 2007: 14,000
CPSC recalls of 2007
452
Recalls of 2007 with one of the same hazards
25%
Recalls of 2007 in the category Dishwashers
1%
Recalls on the register that name GE Consumer & Industrial
7

Other recalls of the firm

Official channels

Cite this page

Recall Register. CPSC recall 07190. https://recallregister.com/product/3621-general-electric-recalls-dishwashers-due-to-fire-hazard/. Source: CPSC Recall Retrieval Web Services. Data through .

Sources

Source
US Consumer Product Safety Commission
Licence
US government work, public domain
Data retrieved
30 Sep 2026
Newest CPSC recall on the register
24 Sep 2026

The CPSC notice is the authority. The hazard names come from the hazard text of CPSC. The category is the product type that CPSC gives. How the register is made. Report an error.

Questions

Does CPSC recall 07190 report injuries?
The CPSC notice says: GE has received 191 reports of overheated wiring, including 56 reports of property damage. There were 12 reports of fires that escaped the dishwasher. Fire damage was limited to the dishwasher or the adjacent area. No injuries have been reported.
Where was the product sold?
The CPSC notice says: Department and appliance stores from September 1997 through December 2001 for about $400.
How many units are in CPSC recall 07190?
The CPSC notice gives this number: About 2.5 million
Where was the product made?
The CPSC notice gives: United States