Recall Register

Safe Generator Use for Y2K: CPSC, DeVilbiss Air Power Company Alert Consumers About Gasoline Tanks on Certain Portable Generators

CPSC recall 00047. Recall date: .

Hazard, in the words of CPSC

CPSC and DAPC are investigating whether the fuel tanks on the generators can crack where the tanks mount on the frame, posing a fire hazard. As a precaution until that evaluation is complete, consumers should not put more than three gallons of gasoline in the fuel tanks at any time.

Remedy, in the words of CPSC

Any consumer who has seen leakage from the tank should not use the generator and should contact DAPC to obtain a free warranty replacement tank.

CPSC recall 00047 has the recall date 30 Dec 1999. The notice names the firm DeVilbiss Air Power Company (DAPC). The recall has about 295,000 units. The median CPSC recall of 1999 has 22,300 units. This register puts the recall under the hazard Fire. CPSC gives the product type Generators.

Federal law prohibits any person from selling products subject to a Commission ordered recall or a voluntary recall undertaken in consultation with the CPSC.

CPSC publishes these words. Source: CPSC recall notices, section About the U.S. CPSC, read on . The hazard, the remedy and the incident text on this site are the words of the CPSC recall notice. Newest CPSC recall on the register: .

More of the notice

The hazard and the remedy are at the top of the page. Each quotation is the text of CPSC.

CPSC recall 00047: incidents, units, products and firms
Incidents and injuries
Each year, carbon monoxide from fuel-burning appliances kills approximately 200 people and sends 10,000 people to hospital emergency rooms. Symptoms of carbon monoxide poisoning are similar to the flu, including nausea, headache, dizziness, and irregular breathing. Exposure to high levels of carbon monoxide can cause death.
Units295,000
Description
The only generators affected by this notice have the following brand names: DeVilbiss Air Power Company, EX-CELL, PowerBack, Companion Model 919-32721, and Craftsman Model No. 919-32651. The seven gallon tanks that are affected include only those tanks that bear dates prior to June 1, 1999. The date is on the serial barcode label found on one of the gasoline tank support rails and on the shipping carton label.
ProductPortable generators, About 295,000, Generators
Sold atThese generators were sold nationwide from February 1996 until June 1999.
ManufacturerDeVilbiss Air Power Company (DAPC)

Recall notice: The page that CPSC publishes for one recall of a consumer product. It states the product, the hazard, the remedy and the incidents.

Hazard: The way a product can cause harm, in the words of the CPSC recall notice. This site also puts each recall under short hazard names.

Remedy: What the manufacturer or the firm does about a recalled product. The agency record states the remedy of each recall.

Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.

The recall in context

Units in this recall
295,000Median of 1999: 22,300
CPSC recalls of 1999
156
Recalls of 1999 with one of the same hazards
30%
Recalls of 1999 in the category Generators
1%
Recalls on the register that name DeVilbiss Air Power Company (DAPC)
1

Official channels

Cite this page

Recall Register. CPSC recall 00047. https://recallregister.com/product/2786-safe-generator-use-for-y2k-cpsc-devilbiss-air-power-company-alert-cons/. Source: CPSC Recall Retrieval Web Services. Data through .

Sources

Source
US Consumer Product Safety Commission
Licence
US government work, public domain
Data retrieved
30 Sep 2026
Newest CPSC recall on the register
24 Sep 2026

The CPSC notice is the authority. The hazard names come from the hazard text of CPSC. The category is the product type that CPSC gives. How the register is made. Report an error.

Questions

Does CPSC recall 00047 report injuries?
The CPSC notice says: Each year, carbon monoxide from fuel-burning appliances kills approximately 200 people and sends 10,000 people to hospital emergency rooms. Symptoms of carbon monoxide poisoning are similar to the flu, including nausea, headache, dizziness, and irregular breathing. Exposure to high levels of carbon monoxide can cause death.
Where was the product sold?
The CPSC notice says: These generators were sold nationwide from February 1996 until June 1999.
How many units are in CPSC recall 00047?
The CPSC notice gives this number: About 295,000