Recall Register

Food, drugs, devices › Covidien Llc

Device recall: LigaSure Blunt Tip Laparoscopic Sealer/Divider, Nano-Coated, Product Number LF1837

FDA enforcement event 89182 · Class II · initiated 6 Dec 2021 · status Terminated · terminated 11 May 2023

DeviceVoluntary: Firm initiated1 product recordMansfield, MA

FDA enforcement event 89182 is a device recall by Covidien Llc of Mansfield, MA, initiated 6 Dec 2021 and classified Class II, with 1 product record.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 89% of the 900 device enforcement events initiated in 2021 carry the same class.

Status: Terminated, terminated 11 May 2023. Initiation: voluntary: firm initiated. Covidien Llc has 77 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Covidien Llc, Mansfield, MA.

Reason for recall

"Customers reported that the device jaws were difficult to open or would not open following application on tissue. Use of a device with this potential assembly issue could result in the potential for bleeding, unintended tissue injury or loss, and delay in treatment while an alternate device is obtained."

Distribution

"Worldwide Distribution in the countries of Australia, Austria, Belgium, Czech Republic, France, Germany, Ireland, Kazakhstan, Netherlands, Spain, United Kingdom. No US distribution."

Product records

Recall numberProductQuantityClassStatusReport date
Z-0495-2022LigaSure Blunt Tip Laparoscopic Sealer/Divider, Nano-Coated, Product Number LF1837504 devicesClass IITerminated19 Jan 2022

Context

89%of 2021 device events are Class II900 events that year
1product record in this eventfirm median: 1
77events on this register for the firm

Other enforcement events for Covidien Llc

InitiatedProduct (first record)TypeClassRecords
13 May 2026EndoFLIP System that includes: ENDOFLIP 1 SYSTEM EF-100 05391530810050 10884521809307 REFURBISHED SYSTEM RFG-EF100 ENDOFDeviceClass II1
23 Apr 2026Covidien Mon-a-Therm Esophageal Stethoscope with Temperature Sensor 400TM REF: 90042DeviceClass II3
23 Apr 2026Covidien Shiley Disposable Decannulation Plug REF DDCP UDI-DI code: 10884522004060 Product Codes that include the CovidiDeviceClass II1
15 Apr 2026COVIDIEN Shiley Tracheostomy Tube Cuffed with Inner Cannula REF 6FEN UDI-DI code: 60884522007028 The devices are intendeDeviceClass II1
30 Jan 2026HealthCast "Vital Sync" Remote Patient Monitoring System which consists of: Product Number: VSLBASE03P / VITALSYNCSW03 MDeviceClass II1
25 Apr 2024EsoFLIP, 30mm BALLOON DILATION CATHETER, REF ES-330, Rx OnlyDeviceClass II1
2 Jun 2023Covidien Cytosponge Cell Collection Device, REF: CYTO-201; and Covidien Cytosponge Cell Collection Kit, REF: CYTO-KIT-USDeviceClass II1
22 May 2023Medtronic ILLUMISITE Platform Console, Model Number ILS-1000-CSDeviceClass II1
23 Nov 2022COVIDIEN Emprint Ablation Catheter with Thermosphere Technology, Bronchoscopic Ablation, REF CA108L1DeviceClass II1
19 Aug 2022Puritan Bennett 560 Ventilator, PB560, CFN 4096600DeviceClass II1

All 77 events for Covidien Llc

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Customers reported that the device jaws were difficult to open or would not open following application on tissue. Use of a device with this potential assembly issue could result in the potential for bleeding, unintended tissue injury or loss, and delay in treatment while an alternate device is obtained."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution in the countries of Australia, Austria, Belgium, Czech Republic, France, Germany, Ireland, Kazakhstan, Netherlands, Spain, United Kingdom. No US distribution."

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 11 May 2023. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.