Food, drugs, devices › Carl Zeiss Meditec, Inc.

Device recall: The PLEX Elite 9000, a Swept-Source OCT [SS-OCT] - Product Usage: The PLEX Elite 9000 Swept-Source OCT [SS-OCT] is a non

FDA enforcement event 83229 · Class II · initiated 16 Oct 2018 · status Terminated · terminated 11 Jun 2021

DeviceVoluntary: Firm initiated1 product recordDublin, CA

FDA enforcement event 83229 is a device recall by Carl Zeiss Meditec, Inc. of Dublin, CA, initiated 16 Oct 2018 and classified Class II, with 1 product record.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 92% of the 1,074 device enforcement events initiated in 2018 carry the same class.

Status: Terminated, terminated 11 Jun 2021. Initiation: voluntary: firm initiated. Carl Zeiss Meditec, Inc. has 7 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Carl Zeiss Meditec, Inc., Dublin, CA.

Reason for recall

"Under certain fault conditions, the existing design may expose the operator to a hazardous voltage when contacting the metal enclosure (including mounting screws) around the up/down switch."

Distribution

"Worldwide distribution - US Nationwide distribution in the states of CA, TX, NY, MA, OH, PA, IA, , KY, FL, MI, IL, MD and Germany, Japan, Switzerland, France Italy, Australia, Austria, Korea, China,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-0770-2020The PLEX Elite 9000, a Swept-Source OCT [SS-OCT] - Product Usage: The PLEX Elite 9000 Swept-Source OCT [SS-OCT] is a non- contact, high resolution, wide field of view tomographic and biomicroscopic imaging device intended for in-vivo viewing, axial cross-sectional and three-dimensional imaging of posterior ocular…151 devicesClass IITerminated8 Jan 2020

Context

92%of 2018 device events are Class II1,074 events that year
1product record in this eventfirm median: 1
7events on this register for the firm

Other enforcement events for Carl Zeiss Meditec, Inc.

InitiatedProduct (first record)TypeClassRecords
14 Jan 2022CIRRUS HD-OCT, Models 5000 AngioPlex and 6000 AngioPlexDeviceClass II1
8 Jul 2021Chassis Label - "CIRRUS HD-OCT Rx-Only" Product Label Exterior RX - "CIRRUS HD-OCT Model 6000"DeviceClass II1
6 Dec 2018VisuMax Software Version 2.10.13 with activated Software-Module ReLEx (SMILE) option used in conjunction with the VisuMaDeviceClass II1
23 Oct 2013Zeiss brand IOLMaster, Version 1-5, Biomicroscope, Slit-Lamp, AC-Powered, Product is manufactured by Carl Zeiss Meditec DeviceClass II2
18 Apr 2013Zeiss brand OPMI Pentero C, Surgical microscope and accessories, Model: OPMI Pentero C, Product Numbers: 302583-9001-000DeviceClass II1
25 Oct 2012INTRABEAM Balloon Applicator Set; 3.0 cm, Carl Zeiss Meditec AG, Oberkochen, Germany INTRABEAM System is intended for raDeviceClass II3

All 7 events for Carl Zeiss Meditec, Inc.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Under certain fault conditions, the existing design may expose the operator to a hazardous voltage when contacting the metal enclosure (including mounting screws) around the up/down switch."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide distribution - US Nationwide distribution in the states of CA, TX, NY, MA, OH, PA, IA, , KY, FL, MI, IL, MD and Germany, Japan, Switzerland, France Italy, Australia, Austria, Korea, China,…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 11 Jun 2021. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.