Device recall: VNS Therapy Programmer, Model 3000, v1.0 System

FDA enforcement event 80062 · Class II · initiated 13 Nov 2017 · status Terminated · terminated 31 Oct 2022

DeviceVoluntary: Firm initiated1 product recordHouston, TX

FDA enforcement event 80062 is a device recall by Cyberonics, Inc of Houston, TX, initiated 13 Nov 2017 and classified Class II, with 1 product record.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 93% of the 1,091 device enforcement events initiated in 2017 carry the same class.

Status: Terminated, terminated 31 Oct 2022. Initiation: voluntary: firm initiated. Cyberonics, Inc has 8 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Cyberonics, Inc, Houston, TX.

Reason for recall

"Certain Model 3000 programming events can result in miscalculation of parameters stored in the Models 103, 104, 105, and 106 generators. During these programming events, the miscalculations can lead to: " Delivery of more stimulation than intended, resulting in painful stimulation or other common side effects (Model 106 only); " No stimulation in the case of device disablement (Burst Watchdog…"

Distribution

"AL, CA, CO, DE, FL, GA, ID, IL, IN, ME, MO, MS, NC, NJ, NY, PA, TN, TN, TX, UT, WA and WI"

Product records

Recall numberProductQuantityClassStatusReport date
Z-2255-2018VNS Therapy Programmer, Model 3000, v1.0 System252Class IITerminated27 Jun 2018

Context

93%of 2017 device events are Class II1,091 events that year
1product record in this eventfirm median: 1
8events on this register for the firm

Other enforcement events for Cyberonics, Inc

InitiatedProduct (first record)TypeClassRecords
2 Dec 2017VNS(R) Therapy Programmer, GMDN: 44077, Model 3000 v1.0.2.2 Intended Use/Indications: United States Indications for Use:DeviceClass II1
13 Jun 2017VNS Therapy¿ AspireHC¿ Generator, VNS Therapy¿ AspireSR¿ Generator. Model No. 105. Product Usage: United States IndicatiDeviceClass II2
18 Dec 2015VNS Therapy AspireSR Generator Model 106. Indicated for use as an adjunctive therapy in reducing the frequency of seizurDeviceClass II1
18 Nov 2015Cyberonics Vagus Nerve Stimulator VNS Therapy AspireSR Generator, Model 106DeviceClass II1
7 Oct 2015Cyberonics Vagus Nerve Stimulator (VNS) Therapy AspireSR Generator, Model 106DeviceClass II1
6 Mar 2015VNS Therapy DemiPulse Generator Model 103 and VNS Therapy DemiPulse Duo Generator Model 104; CYBERONICS, INC.DeviceClass II1
20 Nov 2014Cyberonics VNS Therapy AspireHC, Model 105 Generator. The Cyberonics VNS Therapy System consists of the implantable VNS DeviceClass II1

All 8 events for Cyberonics, Inc

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Certain Model 3000 programming events can result in miscalculation of parameters stored in the Models 103, 104, 105, and 106 generators. During these programming events, the miscalculations can lead to: " Delivery of more stimulation than intended, resulting in painful stimulation or other common side effects (Model 106 only); " No stimulation in the case of device disablement (Burst Watchdog…"

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "AL, CA, CO, DE, FL, GA, ID, IL, IN, ME, MO, MS, NC, NJ, NY, PA, TN, TN, TX, UT, WA and WI"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 31 Oct 2022. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.