Recall Register

Food, drugs, devices › Aesculap Implant Systems LLC

Device recall: DS Titanium Ligation Clip, used in laparoscopic surgery

FDA enforcement event 79530 · Class II · initiated 22 Jan 2018 · status Terminated · terminated 24 Sep 2019

DeviceVoluntary: Firm initiated2 product recordsCenter Valley, PA

FDA enforcement event 79530 is a device recall by Aesculap Implant Systems LLC of Center Valley, PA, initiated 22 Jan 2018 and classified Class II, with 2 product records.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 92% of the 1,074 device enforcement events initiated in 2018 carry the same class.

Status: Terminated, terminated 24 Sep 2019. Initiation: voluntary: firm initiated. Aesculap Implant Systems LLC has 35 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Aesculap Implant Systems LLC, Center Valley, PA.

Reason for recall

"Added a contraindication to IFU: Do not use the DS clips for living donor nephrectomies. Added other contraindications. A publication from 2017 recommended Aesculap DS Clips for kidney transplantation with living donors. The information from this publication was not approved or validated by the firm."

Distribution

"US and Canada distribution"

Product records

Recall numberProductQuantityClassStatusReport date
Z-1290-2018DS Titanium Ligation Clip, used in laparoscopic surgery9621Class IITerminated11 Apr 2018
Z-1291-2018DS Titanium Ligation Clip Appliers, used in laparoscopic surgery270Class IITerminated11 Apr 2018

Context

92%of 2018 device events are Class II1,074 events that year
2product records in this eventfirm median: 1
35events on this register for the firm

Other enforcement events for Aesculap Implant Systems LLC

InitiatedProduct (first record)TypeClassRecords
20 Jul 2023For intraventricular indications mainly used for operations within the brain ventricles. Product Code: FF399RDeviceClass II1
18 May 2023Aesculap Surgical Needle, straight, 3 1/2", (90 mm), 13GA, width: 2,400 mm, non-sterile, reusable Article Number: MD610DeviceClass II1
21 Mar 2023Aesculap Caiman Articulating D5/360MM - An electrosurgical cutting and coagulation device for cutting/coagulation/ablatiDeviceClass II1
23 Feb 2023Caspar Cervical Retractor (CCR) Basket ME754 - Lid Only and ME764 Casper Cervical Retractor (CCR) Basket Full System - LDeviceClass II1
15 Jul 2022Aesculap ENNOVATE SET SCREW STERILE-implants are used for dorsal monosegmental and multisegmental stabilization of the lDeviceClass II1
14 Jul 2022Aeos¿ Robotic Digital Microscope with software versions 2.7 or earlier Article Number: PV010DeviceClass II1
25 Oct 2021MODULIFT VBR SZ.M 4MM SET SCREW DRIVER, MF790R, part of Modulift VBR Medium Instrument Set, ST-0441DeviceClass II1
30 Jun 2021RIGHT CORONAL BENDER, TEK1940. Instrument used during spinal surgery.DeviceClass II2
16 Apr 2021PAS-PORT PROXIMAL ANASTOMOSIS SYSTEM Catalog Number: FC700SUDeviceClass II2
19 Mar 2021Univation X System knee implant devices as follows: Catalog/Product: NL470 UNIVATION F MENISCAL COMP.T1 RM/LM 7MM; NL471DeviceClass II8

All 35 events for Aesculap Implant Systems LLC

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Added a contraindication to IFU: Do not use the DS clips for living donor nephrectomies. Added other contraindications. A publication from 2017 recommended Aesculap DS Clips for kidney transplantation with living donors. The information from this publication was not approved or validated by the firm."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "US and Canada distribution"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 24 Sep 2019. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.