Food, drugs, devices › Brainlab AG

Device recall: BRAINLAB EXACTRAC VERO, Model/Catalog Numbers: 46228 EXACTRAC VERO 3.5 46238 EXACTRAC VERO 3.5 46216 EXACTRAC VERO SW UP

FDA enforcement event 78488 · Class II · initiated 3 Nov 2017 · status Terminated · terminated 14 Dec 2020

DeviceVoluntary: Firm initiated1 product recordMunich, N/A

Brainlab AG (Munich, N/A) initiated this device recall on 3 Nov 2017; FDA lists 1 product record under event 78488, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 93% of the 1,091 device enforcement events initiated in 2017 carry the same class.

Status: Terminated, terminated 14 Dec 2020. Initiation: voluntary: firm initiated. Brainlab AG has 36 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Brainlab AG, Munich, N/A, Germany.

Reason for recall

"Brainlab has internally detected that under specific conditions ExacTrac Vero may not correctly account for this ring angle correction during the calculation of the corresponding couch shift. This may result in the treatment couch not moving to the exact planned position resulting in a deviation between the planned and the treatment target position. This deviation may not be clearly visible to…"

Distribution

"Worldwide Distribution - US Distribution and to the countries of : Belgium, Canada, France, Germany, Italy, Japan and S. Korea"

Product records

Recall numberProductQuantityClassStatusReport date
Z-0172-2018BRAINLAB EXACTRAC VERO, Model/Catalog Numbers: 46228 EXACTRAC VERO 3.5 46238 EXACTRAC VERO 3.5 46216 EXACTRAC VERO SW UPDATE 3.5.2 TO 3.5.3 46218 EXACTRAC VERO SW UPDATE 3.5.3 TO 3.5.4 The ExacTrac Vero system is intended to be used in conjunction with the MHI-TM2000 Radiation Therapy Linear Accelerator System…28 unitsClass IITerminated6 Dec 2017

Context

93%of 2017 device events are Class II1,091 events that year
1product record in this eventfirm median: 1
36events on this register for the firm

Other enforcement events for Brainlab AG

InitiatedProduct (first record)TypeClassRecords
10 Feb 2025Origin Data Management software versions 3.1.0, 3.1.1, 3.1.2, 3.2.0, 3.2.1DeviceClass II1
2 Mar 2023Cirq Arm System 2.0DeviceClass II1
14 Feb 2023Brainlab ExacTrac Dynamic software, Medical Charged-Particle Radiation Therapy System, model 20910-01E and 20910-01F.DeviceClass II1
25 Feb 2022ExacTrac Dynamic software model numbers: 20910-01, ETD Positioning and Moni. 1.0.0 INST; 20910-01A, ETD Positioning and DeviceClass II1
14 May 2021ExacTrac Dynamic software, Model 20910-01B ETD Positioning and Monitoring Installer 1.0.2 - Product Usage: intended to pDeviceClass II1
1 Mar 2021ExacTrac Dynamic (Medical Charged-Particle Radiation Therapy System).DeviceClass II1
31 Aug 2020Ultrasound Navigation Software 1.0 and Ultrasound Integration Software for Cranial/ENT Navigation 3.0.x and 3.1.x - ProdDeviceClass II1
20 Aug 2020Cirq Arm System - Model SBS 1.3.2 (Art.No. 56000-01B) and SBS 1.4 (Art.No. 56000-01C) of the CIRQ Arm System (56000 and DeviceClass II1
16 Jul 2020BRAINLAB Curve; Model/catalogue (article) numbers for Curve: 19901; 19901B; 19900; 19905 UDI (GTIN) for Curve: 040564811DeviceClass II2
25 Sep 2019Patient Data Manager, Model/Catalogue Numbers: 25100-09 - PATIENT DATA MANAGER 2.1.1LICENSE ONLY 25100-10 - PATIENT DATADeviceClass II1

All 36 events for Brainlab AG

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Brainlab has internally detected that under specific conditions ExacTrac Vero may not correctly account for this ring angle correction during the calculation of the corresponding couch shift. This may result in the treatment couch not moving to the exact planned position resulting in a deviation between the planned and the treatment target position. This deviation may not be clearly visible to…"

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution - US Distribution and to the countries of : Belgium, Canada, France, Germany, Italy, Japan and S. Korea"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 14 Dec 2020. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.