Recall Register

Food, drugs, devices › Integra LifeSciences Corp.

Device recall: Cadence Size 5 Left Tibial Tray Implant, designed to treat ankle arthritis through replacement of the ankle joint with a

FDA enforcement event 74173 · Class II · initiated 29 Apr 2016 · status Terminated · terminated 19 Oct 2016

DeviceVoluntary: Firm initiated1 product recordPlainsboro, NJ

FDA enforcement event 74173 is a device recall by Integra LifeSciences Corp. of Plainsboro, NJ, initiated 29 Apr 2016 and classified Class II, with 1 product record.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 91% of the 1,232 device enforcement events initiated in 2016 carry the same class.

Status: Terminated, terminated 19 Oct 2016. Initiation: voluntary: firm initiated. Integra LifeSciences Corp. has 79 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Integra LifeSciences Corp., Plainsboro, NJ.

Reason for recall

"As a result of an internal review of all labeling for the Cadence System, it was determined that the outer package label for the Size 5 Left Tibial Tray Implant reflects the material composition incorrectly. The labeling incorrectly reflects the material as Cobalt Chromium instead of Titanium."

Distribution

"NC and PA"

Product records

Recall numberProductQuantityClassStatusReport date
Z-2086-2016Cadence Size 5 Left Tibial Tray Implant, designed to treat ankle arthritis through replacement of the ankle joint with a prosthesis, thereby reducing pain, restoring alignment, and allowing for movement at the replaced joint. Catalog Number: 10207205; Lot Number #QJ024812 unitsClass IITerminated6 Jul 2016

Context

91%of 2016 device events are Class II1,232 events that year
1product record in this eventfirm median: 1
79events on this register for the firm

Other enforcement events for Integra LifeSciences Corp.

InitiatedProduct (first record)TypeClassRecords
6 Feb 2025AURORA Surgiscope System, Sterile, single use device that contains a Sheath, Obturator, and Imager. Manufacturer's ProduDeviceClass II1
10 Jan 2025Brand Name: MediHoney¿ Gel Product Name: MediHoney¿ Wound & Burn Dressing Gel Model/Catalog Number: 31815 Software VersiDeviceClass II1
16 Dec 2024CODMAN CERTAS Plus Programmable Valve Inline Small Valve Only. Model Number: 828810 Implantable device that provides conDeviceClass II3
26 Sep 2024Duraform Dural Graft Implant, Size 3x3 , Model Number 80-1477US Lot CT007694DeviceClass II1
20 Sep 2024MICR PATIE RND Model/Catalog Number: 801396. CODMAN Surgical Patties and CODMAN Surgical Strips are manufactured of COTTDeviceClass II22
13 Sep 2024MEDIHONEY Dressing with Active Leptospermum Honey Wound and Burn Dressing W/APPLICATOR, 1.5oz tube (Model Number 31515) DeviceClass II1
9 Jul 2024TruDi NAV Suction, 0 Degrees; Model/Catalog Number: TDNS000Z. TruDi" NAV Suction Instruments are intended for use with tDeviceClass II1
7 Jun 2024AURORA Surgiscope System. Sterile, single use device that contains a Sheath, Obturator, and Imager.DeviceClass II1
29 May 2024CUSA Excel C2600 23KHz Straight Handpiece-Indicated for use in surgical procedures where fragmentation, emulsification aDeviceClass II1
7 May 2024CODMAN BACTISEAL EVD Catheter Set - Indicated for gaining access to the ventricles of the brain and can be used with dimDeviceClass II3

All 79 events for Integra LifeSciences Corp.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "As a result of an internal review of all labeling for the Cadence System, it was determined that the outer package label for the Size 5 Left Tibial Tray Implant reflects the material composition incorrectly. The labeling incorrectly reflects the material as Cobalt Chromium instead of Titanium."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "NC and PA"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 19 Oct 2016. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.