Recall Register

Food, drugs, devices › Integra LifeSciences Corp.

Device recall: Integra Titan Reverse Shoulder System right and left head cutting templates, 142.5 degrees. The Reverse Shoulder System

FDA enforcement event 69596 · Class II · initiated 24 Oct 2014 · status Terminated · terminated 21 Jul 2015

DeviceVoluntary: Firm initiated1 product recordPlainsboro, NJ

Integra LifeSciences Corp. (Plainsboro, NJ) initiated this device recall on 24 Oct 2014; FDA lists 1 product record under event 69596, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 91% of the 1,176 device enforcement events initiated in 2014 carry the same class.

Status: Terminated, terminated 21 Jul 2015. Initiation: voluntary: firm initiated. Integra LifeSciences Corp. has 79 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Integra LifeSciences Corp., Plainsboro, NJ.

Reason for recall

"A single lot of left and a single lot of right Reverse Shoulder System cutting templates were manufactured incorrectly. Specifically, the threaded handle has been welded backwards on the template resulting in the cutting angle being the reverse of what it should be."

Distribution

"Nationwide Distribution including the states of TX, CA, OH, MS, VA, IL, TN, GA, CA, FL, and AZ."

Product records

Recall numberProductQuantityClassStatusReport date
Z-0197-2015Integra Titan Reverse Shoulder System right and left head cutting templates, 142.5 degrees. The Reverse Shoulder System Cutting Template, 142.5 degrees is an accessory for use with the Integra Titan Reverse Shoulder System. It is used to project the osteotomy angle on the humeral head.12 unitsClass IITerminated19 Nov 2014

Context

91%of 2014 device events are Class II1,176 events that year
1product record in this eventfirm median: 1
79events on this register for the firm

Other enforcement events for Integra LifeSciences Corp.

InitiatedProduct (first record)TypeClassRecords
6 Feb 2025AURORA Surgiscope System, Sterile, single use device that contains a Sheath, Obturator, and Imager. Manufacturer's ProduDeviceClass II1
10 Jan 2025Brand Name: MediHoney¿ Gel Product Name: MediHoney¿ Wound & Burn Dressing Gel Model/Catalog Number: 31815 Software VersiDeviceClass II1
16 Dec 2024CODMAN CERTAS Plus Programmable Valve Inline Small Valve Only. Model Number: 828810 Implantable device that provides conDeviceClass II3
26 Sep 2024Duraform Dural Graft Implant, Size 3x3 , Model Number 80-1477US Lot CT007694DeviceClass II1
20 Sep 2024MICR PATIE RND Model/Catalog Number: 801396. CODMAN Surgical Patties and CODMAN Surgical Strips are manufactured of COTTDeviceClass II22
13 Sep 2024MEDIHONEY Dressing with Active Leptospermum Honey Wound and Burn Dressing W/APPLICATOR, 1.5oz tube (Model Number 31515) DeviceClass II1
9 Jul 2024TruDi NAV Suction, 0 Degrees; Model/Catalog Number: TDNS000Z. TruDi" NAV Suction Instruments are intended for use with tDeviceClass II1
7 Jun 2024AURORA Surgiscope System. Sterile, single use device that contains a Sheath, Obturator, and Imager.DeviceClass II1
29 May 2024CUSA Excel C2600 23KHz Straight Handpiece-Indicated for use in surgical procedures where fragmentation, emulsification aDeviceClass II1
7 May 2024CODMAN BACTISEAL EVD Catheter Set - Indicated for gaining access to the ventricles of the brain and can be used with dimDeviceClass II3

All 79 events for Integra LifeSciences Corp.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "A single lot of left and a single lot of right Reverse Shoulder System cutting templates were manufactured incorrectly. Specifically, the threaded handle has been welded backwards on the template resulting in the cutting angle being the reverse of what it should be."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Nationwide Distribution including the states of TX, CA, OH, MS, VA, IL, TN, GA, CA, FL, and AZ."

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 21 Jul 2015. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.