Recall Register

Food, drugs, devices › Brainlab AG

Device recall: Brainlab, Spine & Trauma 3D 2.0, Navigation Software. An intraoperative image-guided localization system to enable minim

FDA enforcement event 67569 · Class II · initiated 18 Nov 2013 · status Terminated · terminated 17 Jul 2017

DeviceVoluntary: Firm initiated1 product recordFeldkirchen, N/A

Brainlab AG (Feldkirchen, N/A) initiated this device recall on 18 Nov 2013; FDA lists 1 product record under event 67569, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 90% of the 1,236 device enforcement events initiated in 2013 carry the same class.

Status: Terminated, terminated 17 Jul 2017. Initiation: voluntary: firm initiated. Brainlab AG has 36 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Brainlab AG, Feldkirchen, N/A, Germany.

Reason for recall

"The "fluoro match registration" function of the Navigation Software Spine & Trauma 3D 2.0 allows the user to intraoperatively match e.g., CT data sets to the current patient anatomy visible on fluoroscopic images, used by the navigation software during spinal surgeries to display the position and orientation of instruments. For this registration function in combination with a digitally integrated"

Distribution

"Worldwide Distribution - US Distribution including the states of AZ, CA,GA, IL, IN, LA, MA, MI, NY, NC, OH, PA, TN, TX and WI and the countries of Australia, Austria, Belgium, Brazil, Chile, Czech…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-1469-2014Brainlab, Spine & Trauma 3D 2.0, Navigation Software. An intraoperative image-guided localization system to enable minimally invasive surgery. Catalog Number: 22264133 unitsClass IITerminated23 Apr 2014

Context

90%of 2013 device events are Class II1,236 events that year
1product record in this eventfirm median: 1
36events on this register for the firm

Other enforcement events for Brainlab AG

InitiatedProduct (first record)TypeClassRecords
10 Feb 2025Origin Data Management software versions 3.1.0, 3.1.1, 3.1.2, 3.2.0, 3.2.1DeviceClass II1
2 Mar 2023Cirq Arm System 2.0DeviceClass II1
14 Feb 2023Brainlab ExacTrac Dynamic software, Medical Charged-Particle Radiation Therapy System, model 20910-01E and 20910-01F.DeviceClass II1
25 Feb 2022ExacTrac Dynamic software model numbers: 20910-01, ETD Positioning and Moni. 1.0.0 INST; 20910-01A, ETD Positioning and DeviceClass II1
14 May 2021ExacTrac Dynamic software, Model 20910-01B ETD Positioning and Monitoring Installer 1.0.2 - Product Usage: intended to pDeviceClass II1
1 Mar 2021ExacTrac Dynamic (Medical Charged-Particle Radiation Therapy System).DeviceClass II1
31 Aug 2020Ultrasound Navigation Software 1.0 and Ultrasound Integration Software for Cranial/ENT Navigation 3.0.x and 3.1.x - ProdDeviceClass II1
20 Aug 2020Cirq Arm System - Model SBS 1.3.2 (Art.No. 56000-01B) and SBS 1.4 (Art.No. 56000-01C) of the CIRQ Arm System (56000 and DeviceClass II1
16 Jul 2020BRAINLAB Curve; Model/catalogue (article) numbers for Curve: 19901; 19901B; 19900; 19905 UDI (GTIN) for Curve: 040564811DeviceClass II2
25 Sep 2019Patient Data Manager, Model/Catalogue Numbers: 25100-09 - PATIENT DATA MANAGER 2.1.1LICENSE ONLY 25100-10 - PATIENT DATADeviceClass II1

All 36 events for Brainlab AG

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "The "fluoro match registration" function of the Navigation Software Spine & Trauma 3D 2.0 allows the user to intraoperatively match e.g., CT data sets to the current patient anatomy visible on fluoroscopic images, used by the navigation software during spinal surgeries to display the position and orientation of instruments. For this registration function in combination with a digitally integrated"

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution - US Distribution including the states of AZ, CA,GA, IL, IN, LA, MA, MI, NY, NC, OH, PA, TN, TX and WI and the countries of Australia, Austria, Belgium, Brazil, Chile, Czech…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 17 Jul 2017. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.