Device recall: Integra Camino Advanced Monitor with Waveform Display Model CAM01 Integra Neurosciences, 311 Enterprise Dr Plainsboro, N

FDA enforcement event 67094 · Class II · initiated 26 Nov 2013 · status Terminated · terminated 13 Feb 2015

DeviceVoluntary: Firm initiated1 product recordPlainsboro, NJ

FDA enforcement event 67094 is a device recall by Integra LifeSciences Corp. of Plainsboro, NJ, initiated 26 Nov 2013 and classified Class II, with 1 product record.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 90% of the 1,236 device enforcement events initiated in 2013 carry the same class.

Status: Terminated, terminated 13 Feb 2015. Initiation: voluntary: firm initiated. Integra LifeSciences Corp. has 79 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Integra LifeSciences Corp., Plainsboro, NJ.

Reason for recall

"Integra became aware through a complaint from a single non-US customer that if the optional SYS/DIAS mode is used on CAM01 monitor that contains Mod 4 Firmware, the displayed values for the systolic and diastolic intracranial pressure (ICP) are reversed. But, if the CAM01 is used with an auxiliary bedside monitor, the bedside monitor displays these values correctly."

Distribution

"Worldwide Distribution - USA ( Nationwide ) and the countries of : UK, Saudi Arabia, South Africa, Brunei, China, France, Poland, Turkey, Greece, Sweden, United Arab Emirates, Russia, Spain,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-0602-2014Integra Camino Advanced Monitor with Waveform Display Model CAM01 Integra Neurosciences, 311 Enterprise Dr Plainsboro, NJ 08536 USA The Camino Advanced Monitor is a compact, portable device for use with Camino 110-4 series of Pressure / Temperature and Pressure Transducer-Tipped Catheters. Pressure and/or Temperature…275 CAM01 MonitorsClass IITerminated8 Jan 2014

Context

90%of 2013 device events are Class II1,236 events that year
1product record in this eventfirm median: 1
79events on this register for the firm

Other enforcement events for Integra LifeSciences Corp.

InitiatedProduct (first record)TypeClassRecords
6 Feb 2025AURORA Surgiscope System, Sterile, single use device that contains a Sheath, Obturator, and Imager. Manufacturer's ProduDeviceClass II1
10 Jan 2025Brand Name: MediHoney¿ Gel Product Name: MediHoney¿ Wound & Burn Dressing Gel Model/Catalog Number: 31815 Software VersiDeviceClass II1
16 Dec 2024CODMAN CERTAS Plus Programmable Valve Inline Small Valve Only. Model Number: 828810 Implantable device that provides conDeviceClass II3
26 Sep 2024Duraform Dural Graft Implant, Size 3x3 , Model Number 80-1477US Lot CT007694DeviceClass II1
20 Sep 2024MICR PATIE RND Model/Catalog Number: 801396. CODMAN Surgical Patties and CODMAN Surgical Strips are manufactured of COTTDeviceClass II22
13 Sep 2024MEDIHONEY Dressing with Active Leptospermum Honey Wound and Burn Dressing W/APPLICATOR, 1.5oz tube (Model Number 31515) DeviceClass II1
9 Jul 2024TruDi NAV Suction, 0 Degrees; Model/Catalog Number: TDNS000Z. TruDi" NAV Suction Instruments are intended for use with tDeviceClass II1
7 Jun 2024AURORA Surgiscope System. Sterile, single use device that contains a Sheath, Obturator, and Imager.DeviceClass II1
29 May 2024CUSA Excel C2600 23KHz Straight Handpiece-Indicated for use in surgical procedures where fragmentation, emulsification aDeviceClass II1
7 May 2024CODMAN BACTISEAL EVD Catheter Set - Indicated for gaining access to the ventricles of the brain and can be used with dimDeviceClass II3

All 79 events for Integra LifeSciences Corp.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Integra became aware through a complaint from a single non-US customer that if the optional SYS/DIAS mode is used on CAM01 monitor that contains Mod 4 Firmware, the displayed values for the systolic and diastolic intracranial pressure (ICP) are reversed. But, if the CAM01 is used with an auxiliary bedside monitor, the bedside monitor displays these values correctly."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution - USA ( Nationwide ) and the countries of : UK, Saudi Arabia, South Africa, Brunei, China, France, Poland, Turkey, Greece, Sweden, United Arab Emirates, Russia, Spain,…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 13 Feb 2015. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.