Recall Register

Food, drugs, devices › Philips Medical Systems (Cleveland) Inc

Device recall: Brilliance iCT, Brilliance 64 and Brilliance Big Bore The Brilliance iCT, Brilliance 64 and Brilliance Big Bore are Comp

FDA enforcement event 66311 · Class II · initiated 7 Mar 2011 · status Terminated · terminated 28 Apr 2014

DeviceVoluntary: Firm initiated1 product recordCleveland, OH

Philips Medical Systems (Cleveland) Inc (Cleveland, OH) initiated this device recall on 7 Mar 2011; FDA lists 1 product record under event 66311, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 89% of the 114 device enforcement events initiated in 2011 carry the same class.

Status: Terminated, terminated 28 Apr 2014. Initiation: voluntary: firm initiated. Philips Medical Systems (Cleveland) Inc has 129 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Philips Medical Systems (Cleveland) Inc, Cleveland, OH.

Reason for recall

"The DoseRight feature suggest a mAs based on the measured patient size, a reference size and a reference mAs. When scanning large children, the suggested mAs may be higher than clinicians would expect."

Distribution

"Worldwide Distribution - US Distribution including the states of DC, IL, IN, MI, MO, NY, OH, OR, PA, TX and VT., and the countries of Australia, Belgium, China, Germany, India, Israel, Italy and The…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-0791-2014Brilliance iCT, Brilliance 64 and Brilliance Big Bore The Brilliance iCT, Brilliance 64 and Brilliance Big Bore are Computed Tomography X-Ray Systems intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes. These devices may…23Class IITerminated5 Feb 2014

Context

89%of 2011 device events are Class II114 events that year
1product record in this eventfirm median: 1
129events on this register for the firm

Other enforcement events for Philips Medical Systems (Cleveland) Inc

InitiatedProduct (first record)TypeClassRecords
5 Aug 2025Pinnacle Radiation Therapy Planning System: Multimodality Simulation Workspace 18.0.5 Model 870258 UDI code: (01)0088483DeviceClass II1
17 Jul 2025Pinnacle 3 with TumorLOC, (870258) Radiation Therapy Planning System SoftwareDeviceClass II1
30 Aug 2022Pinnacle3 Radiation Therapy Planning System, Model numbers 870231 and 870237.DeviceClass II1
19 Sep 2019Forte Gamma Camera System is intended to produce images depicting the anatomical distribution of single-photon and positDeviceClass I5
24 Jun 2019Ingenuity CT, Model # 728326, computed tomography x-ray systemDeviceClass II9
10 Jun 2019BrightView SPECT, Model Number 882480DeviceClass II3
3 Jun 2019Vereos PET/CT, Model No. 882446 Product Usage: Positron Emission Tomography (PET) and X-ray Computed Tomography (CT) sysDeviceClass II1
19 Dec 2018Ingenuity TF PET/CT (non-RoHS), Model Number 882456 This device is a diagnostic imaging system that combines Positron EmDeviceClass II1
18 Oct 2018Brilliance 64, Model 728231 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images DeviceClass II6
4 Sep 2018Vereos PET/CT, Software version 2.0.1. Model Number: 882446 Product Usage: The Philips Vereos PET/CT system is a diagnosDeviceClass II1

All 129 events for Philips Medical Systems (Cleveland) Inc

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "The DoseRight feature suggest a mAs based on the measured patient size, a reference size and a reference mAs. When scanning large children, the suggested mAs may be higher than clinicians would expect."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution - US Distribution including the states of DC, IL, IN, MI, MO, NY, OH, OR, PA, TX and VT., and the countries of Australia, Belgium, China, Germany, India, Israel, Italy and The…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 28 Apr 2014. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.