Device recall: ISE REF Valve, Part No. MU3226 for the AU400, AU640, AU2700, and AU5400 Chemistry Analyzer. Automated chemistry analyzer

FDA enforcement event 66253 · Class II · initiated 9 Sep 2013 · status Terminated · terminated 30 Sep 2014

DeviceVoluntary: Firm initiated2 product recordsBrea, CA

FDA enforcement event 66253 is a device recall by Beckman Coulter Inc. of Brea, CA, initiated 9 Sep 2013 and classified Class II, with 2 product records.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 90% of the 1,236 device enforcement events initiated in 2013 carry the same class.

Status: Terminated, terminated 30 Sep 2014. Initiation: voluntary: firm initiated. Beckman Coulter Inc. has 216 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Beckman Coulter Inc., Brea, CA.

Reason for recall

"The recall was initiated because Beckman Coulter has confirmed that some AU Clinical Chemistry Analyzer ISE units can experience premature ISE REF (Reference) valve failure. Premature valve failure can be detected by the presence of air bubbles in the ISE REF solution tubing on the ISE unit. If air bubbles are present, accuracy of the ISE test results may be affected."

Distribution

"Worldwide Distribution-USA (nationwide) and the countries of Canada, Vietnam, Zambia, and Zimbabwe."

Product records

Recall numberProductQuantityClassStatusReport date
Z-0152-2014ISE REF Valve, Part No. MU3226 for the AU400, AU640, AU2700, and AU5400 Chemistry Analyzer. Automated chemistry analyzers that measures analytes in samples.4584 units total (1173 units in US)Class IITerminated13 Nov 2013
Z-0153-2014ISE REF Valve, Part No. MU7638 for the AU480, AU680, and AU5800 Chemistry Analyzer. Automated chemistry analyzers that measures analytes in samples.4584 units total (1173 units in US)Class IITerminated13 Nov 2013

Context

90%of 2013 device events are Class II1,236 events that year
2product records in this eventfirm median: 1
216events on this register for the firm

Other enforcement events for Beckman Coulter Inc.

InitiatedProduct (first record)TypeClassRecords
15 Jul 2026Beckman Coulter DxC 500i Clinical Analyzer Modules using software version 1.5 or lower: 1) DxC 500 AU Module w/ISE, DxC DeviceClass II2
26 Jun 2026REF # D23352, MicroScan LabPro V5.03 Panel Update 11 (US), Electronic installed on the following instruments: - B1018-28DeviceClass II2
16 Mar 2026Access Total T4 Calibrator, Catalog No. 33805DeviceClass II1
23 Dec 2025CellMek SPS Sample Preparation System, REF: C44603, with softwareDeviceClass II1
26 Nov 2025Beckman Coulter UniCel Dxl 600, Part numbers: A71460, A71461, A30260; Immunoassay Method, Troponin SubunitDeviceClass II2
10 Nov 2025COULTER DxH Diluent, REF 628017 COULTER DxH ECO Diluent REF C67250 For use as an isotonic buffered diluent in conjunctioDeviceClass II1
7 Nov 2025Access 2 Reaction Vessels, individual, disposable, plastic tubes used to process patient, quality control and calibratioDeviceClass II1
1 Oct 2025Beckman Coulter UniCel DxI 600, Part Numbers: A71460, A30260; Photometric Chemistry AnalyzerDeviceClass II2
22 Sep 2025DxFLEX Flow Cytometer Catalog Number C78500 UDI-DI code: 15099590754013 The DxFLEX Flow Cytometer is intended for use asDeviceClass II1
19 Sep 2025DxC 500i Clinical Analyzer Modules, DxC 500 AU Module w/ISE, DxC 500i (Part Number C63522), DxC 500 AU Module, DxC 500i DeviceClass II2

All 216 events for Beckman Coulter Inc.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "The recall was initiated because Beckman Coulter has confirmed that some AU Clinical Chemistry Analyzer ISE units can experience premature ISE REF (Reference) valve failure. Premature valve failure can be detected by the presence of air bubbles in the ISE REF solution tubing on the ISE unit. If air bubbles are present, accuracy of the ISE test results may be affected."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution-USA (nationwide) and the countries of Canada, Vietnam, Zambia, and Zimbabwe."

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 30 Sep 2014. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.