Device recall: Imagecast PACS is an image management system intended to be used by trained professionals, including but not limited to

FDA enforcement event 64740 · Class II · initiated 4 Mar 2011 · status Terminated · terminated 16 May 2016

DeviceVoluntary: Firm initiated1 product recordBarrington, IL

Ge Healthcare It (Barrington, IL) initiated this device recall on 4 Mar 2011; FDA lists 1 product record under event 64740, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 89% of the 114 device enforcement events initiated in 2011 carry the same class.

Status: Terminated, terminated 16 May 2016. Initiation: voluntary: firm initiated. Ge Healthcare It has 17 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Ge Healthcare It, Barrington, IL.

Reason for recall

"In Imagecast PACS versions prior to 3.6.51.01, the estimated magnification factor (0018,1114) was not accounted for. These versions of Imagecast PACS look for values to be present in the following tags to calculate a measurement from pixels to millimeters (mm): (0020,0030) Pixel Spacing and, (0018,1164) Imager Pixel Spacing. Because the estimated magnification factor is not used, distance meas"

Distribution

"Nationwide Distribution: US including states of: AL, AZ, CT, FL, GA, IA, IN, LA, MA, MI, MN, MO, NC, NH, NJ, NY, OH, PA, TX, VA, WI, WV + District of Columbia."

Product records

Recall numberProductQuantityClassStatusReport date
Z-0773-2014Imagecast PACS is an image management system intended to be used by trained professionals, including but not limited to physicians, nurses and medical technicians. The system is used with general purpose computing hardware to acquire, transmit, process and store images and data throughout a clinical environment. Data…43 unitsClass IITerminated22 Jan 2014

Context

89%of 2011 device events are Class II114 events that year
1product record in this eventfirm median: 1
17events on this register for the firm

Other enforcement events for Ge Healthcare It

InitiatedProduct (first record)TypeClassRecords
26 Aug 2013Merge Mammo is a multi-modality, vendor-neutral digital mammography workstation that enables imaging centers to use a siDeviceClass II1
11 Jun 2013The Centricity PACS Workstation is intended for use as a primary diagnostic and analysis tool for diagnostic images by tDeviceClass II1
19 Apr 2013Centricity Enterprise Archive is a software product for receiving, archiving and sending of medical data. DICOM devices DeviceClass II1
12 Mar 2013The Centricity Laboratory System is intended to be an information system designed to support the clinical and administraDeviceClass II1
12 Mar 2013The Centricity Laboratory System is intended to be an information system designed to support the clinical and administraDeviceClass II1
11 Mar 2013Centricity Perinatal and Centricity Intensive Care is intended to be used in clinical departments healthcare delivery syDeviceClass II1
18 Feb 2013Imagecast PACS with Centricity RIS-IC versions prior to 10.6 Update Package 18 Product Usage: is an image management sysDeviceClass II1
20 Nov 2012Centricity Laboratory Core Lab System 4.1 The Centricity Laboratory System is intended to be an information system desigDeviceClass II1
20 Nov 2012The Centricity Laboratory System is intended to be an information system designed to support the clinical and administraDeviceClass II1
20 Nov 2012The Centricity Laboratory System is intended to be an information system designed to support the clinical and administraDeviceClass III1

All 17 events for Ge Healthcare It

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "In Imagecast PACS versions prior to 3.6.51.01, the estimated magnification factor (0018,1114) was not accounted for. These versions of Imagecast PACS look for values to be present in the following tags to calculate a measurement from pixels to millimeters (mm): (0020,0030) Pixel Spacing and, (0018,1164) Imager Pixel Spacing. Because the estimated magnification factor is not used, distance meas"

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Nationwide Distribution: US including states of: AL, AZ, CT, FL, GA, IA, IN, LA, MA, MI, MN, MO, NC, NH, NJ, NY, OH, PA, TX, VA, WI, WV + District of Columbia."

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 16 May 2016. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.