Recall Register

Food, drugs, devices › Hologic, Inc.

Device recall: Hologic Fluoroscan Mini C-Arm Model with InSight2, Software version 4.0 and 4.0.1 The device is a Mini C-arm Fluoroscopi

FDA enforcement event 63180 · Class II · initiated 14 Sep 2012 · status Terminated · terminated 10 Jan 2014

DeviceVoluntary: Firm initiated2 product recordsBedford, MA

FDA enforcement event 63180 is a device recall by Hologic, Inc. of Bedford, MA, initiated 14 Sep 2012 and classified Class II, with 2 product records.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 88% of the 823 device enforcement events initiated in 2012 carry the same class.

Status: Terminated, terminated 10 Jan 2014. Initiation: voluntary: firm initiated. Hologic, Inc. has 41 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Hologic, Inc., Bedford, MA.

Reason for recall

"InSight2, version 4.0 and 4.0.1 - DICOM images stored in PACS may be flipped 180¿around vertical axis. InSight FD, version 5.0.1 and 5.0.2 - DICOM images stored in PACS may be lipped 180¿ around vertical axis as well as 180¿ around a horizontal axis."

Distribution

"Worldwide Distribution - USA (nationwide) and the countries of Argentina, Australia,Belgium, Canada, China, Germany, Ecuador, Spain, France, Great Britain, Greece, Hong Kong, Italy, Japan Korea,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-2452-2012Hologic Fluoroscan Mini C-Arm Model with InSight2, Software version 4.0 and 4.0.1 The device is a Mini C-arm Fluoroscopic Imaging System designed to provide -physicians with general fluoroscopic visualization of a patient, including but not limited to surgical orthopedic and podiatry use, critical and emergency…414 unitsClass IITerminated3 Oct 2012
Z-2453-2012Hologic Fluoroscan Mini C-Arm Model with InSight- FD Software Version 5.0.1and 5.0.2 The device is a Mini C-arm Fluoroscopic Imaging System designed to provide -physicians with general fluoroscopic visualization of a patient, including but not limited to surgical orthopedic and podiatry use, critical and emergency…46 unitsClass IITerminated3 Oct 2012

Context

88%of 2012 device events are Class II823 events that year
2product records in this eventfirm median: 1
41events on this register for the firm

Other enforcement events for Hologic, Inc.

InitiatedProduct (first record)TypeClassRecords
8 Apr 2026SELENIA DIMENSIONS MAMMOGRAPHY SYSTEMS. Model Numbers: SDA-SYS-3000-2D-HTC, SDA-SYS-3000-3D, SDM-SYS-6000-2D, SDM-SYS-60DeviceClass II2
23 Mar 2026Brand Name: Genius" Review Station Product Name: Genius" Review Station Display (Barco Monitor) Model/Catalog Number: CMDeviceClass II1
18 Feb 2026Brand Name: Aptima HPV Assay Product Name: Aptima HPV Assay Model/Catalog Number: 303585 Product Description: Aptima HPVDeviceClass II1
15 Dec 2025Brevera Breast Biopsy System Disposable 9 Gauge Needle. Biopsy Instrument.DeviceClass II1
12 Dec 2025ThinPrep¿ CytoLyt¿ Solution. Buffered Cell Wash Solution.DeviceClass II1
15 Jan 2025Brand Name: Sertera Biopsy Device Product Name: Sertera Biopsy Device Model/Catalog Number: Sertera-14 Software Version:DeviceClass II1
8 Jan 2025The Rapid fFN Specimen Collection Tube (PN: 71550-001) is a component of the Rapid fFN Specimen Collection kit (PN: 7173DeviceClass II1
13 Dec 2024Panther Fusion GBS Assay REF PRD-04484 Kit containing Panther Fusion GBS Reagent Cartridge IVD.DeviceClass II1
8 Nov 2024Panther Fusion SARS-CoV-2/Flu A/B/RSV Assay, REF: PRD-07400DeviceClass II1
10 Oct 2024BioZorb Marker. Radiographic soft tissue marker.DeviceClass I1

All 41 events for Hologic, Inc.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "InSight2, version 4.0 and 4.0.1 - DICOM images stored in PACS may be flipped 180¿around vertical axis. InSight FD, version 5.0.1 and 5.0.2 - DICOM images stored in PACS may be lipped 180¿ around vertical axis as well as 180¿ around a horizontal axis."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution - USA (nationwide) and the countries of Argentina, Australia,Belgium, Canada, China, Germany, Ecuador, Spain, France, Great Britain, Greece, Hong Kong, Italy, Japan Korea,…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 10 Jan 2014. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.