NHTSA lists 9 equipment recall campaigns for Weldon. NHTSA received the reports from 2020 to 2026. The campaigns have 18,520 units in total. The newest campaign is 26E030000. NHTSA received the report on 13 May 2026.
The defect, the consequence and the remedy on this page are the summaries in the NHTSA recall file. The file names the manufacturer that filed each recall report.
NHTSA recall file through .
Recall campaigns
9 campaigns, newest first. 18,520 units in total.
26E030000Received . 116 units.
Equipment / Emergency / Siren/Lighting/Strobes / Controls
- Defect, in the NHTSA record
Hale Products Inc (Hale) is recalling certain Weldon UV800 Display Unit user interfaces, with part numbers 610-00060-080-51, 610-00060-080-50, 610-00060-081, and 610-00091. The display may stop responding to touch commands or fail to power on, preventing the activation of exterior emergency lights, fire fighting and other emergency equipment.
- Consequence, in the NHTSA record
A loss of exterior lights can reduce the visibility of the vehicle to other drivers, increasing the risk of a crash. Inoperative equipment can delay emergency response, increasing the risk of injury.
- Remedy, in the NHTSA record
Hale will update the firmware and install a monitor system, free of charge. Hale is expected to notify the affected vehicle manufacturers May 17, 2026. Owners may contact Hale customer service at 1-800-533-3569. Hale's number for this recall is SB-189.
Products named: Weldon UV800 Display Unit.
Report filed by Hale Products Inc. Manufacturer campaign number SB-189. Owner notification date in the NHTSA record: .
26E020000Received . 1,959 units.
Equipment / Electrical / Infotainment / Video (Touch)screen/Monitor/Unit
- Defect, in the NHTSA record
Weldon Division of Akron Brass (Akron Brass) is recalling certain Enovation Controls PowerView 700 displays with part number 610-00060-080-ST or 610-00060-080. The display may stop responding to touch commands or fail to power on, preventing the activation of exterior emergency lights, fire fighting and other emergency equipment.
- Consequence, in the NHTSA record
A loss of exterior lights can reduce the visibility of the vehicle to other drivers, increasing the risk of a crash. Inoperative equipment can delay emergency response, increasing the risk of injury.
- Remedy, in the NHTSA record
Akron Brass will update the firmware, free of charge. Owner notification letters were mailed April 27, 2026. Owners may contact Akron Brass customer service at 1-800-228-1161. Akron Brass number for this recall is TBS-26-04-034.
Products named: Weldon UV800 Display Unit.
Report filed by Weldon Division of Akron Brass. Manufacturer campaign number TSB 26-04-034. Owner notification date in the NHTSA record: .
24E006000Received . 769 units.
Electrical System
- Defect, in the NHTSA record
Weldon Division of Akron Brass (Akron Brass) is recalling certain Hercules HC 1.7 Node multiplex nodes, part number 6060-2010-00. In the event of a short circuit or wiring failure, the firmware in the node may fail to shut off the output pin, resulting in overloaded electrical circuits.
- Consequence, in the NHTSA record
Overloaded electrical circuits can overheat, increasing the risk of fire.
- Remedy, in the NHTSA record
Weldon will update the firmware, free of charge. Owner notification letters were mailed February 08, 2024. Owners may contact Akron Brass customer service at 1-800-228-1161. Akron Brass number for this recall is TBS-24-002. This recall involves the same issue as stated in previous safety recall 23E-084. Vehicle owners may have vehicles that are affected by one or both recalls.
Products named: Weldon V-Mux Hercules HC Node.
Report filed by Weldon Division of Akron Brass. Manufacturer campaign number TSB 24-002. Owner notification date in the NHTSA record: .
23E084000Received . 6,792 units.
Electrical System / Wiring
- Defect, in the NHTSA record
Weldon Division of Akron Brass (Akron Brass) is recalling certain 8x16 Input-Output Node Vehicle Multiplex Systems, part number 6030-2000-00. In the event of a short circuit or wiring failure, the firmware may fail to shut off the output pin, resulting in overloaded electrical circuits.
- Consequence, in the NHTSA record
Overloaded electrical circuits can overheat, increasing the risk of fire.
- Remedy, in the NHTSA record
Weldon will update the firmware, free of charge. Owner notification letters were mailed January 03, 2024. Owners may contact Akron Brass customer service at 1-800-228-1161.
Products named: Weldon 8X16 Input-Output Node.
Report filed by Weldon Division of Akron Brass. Owner notification date in the NHTSA record: .
22E037000Received . 860 units.
Electrical System
- Defect, in the NHTSA record
Weldon Division of Akron Brass (Akron Brass) is recalling certain V-mux Hercules HC Node 1.5 electrical multiplex modules, with part number 6060-1000-00. An additional resistor was inadvertently installed on the printed circuit board, which can disrupt CAN network communication and cause vehicle lighting to fail.
- Consequence, in the NHTSA record
Inoperable vehicle lighting can reduce visibility and increase the risk of a crash.
- Remedy, in the NHTSA record
Weldon will work with vehicle manufacturers and provide replacement modules, free of charge. Owner notification letters were mailed on May 6, 2022. Owners may contact Akron Brass customer service at 1-800-228-1161. Akron Brass number for this recall is TSB 22-001.
Products named: Weldon V-Mux Hercules HC Node.
Report filed by Weldon Division of Akron Brass. Manufacturer campaign number TSB 22-001. Owner notification date in the NHTSA record: .
22E007000Received . 6,315 units.
Exterior Lighting / Back Up Lights
- Defect, in the NHTSA record
Weldon Division of Akron Brass (Weldon) is recalling certain Weldon Rear Combination Lamps, model 40958, and part numbers 4095877C92 and 5878C92. The LED backup lights are the incorrect color white. As such, these lights fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
- Consequence, in the NHTSA record
Incorrect color backup lights may affect vehicle visibility to other drivers, increasing the risk of a crash.
- Remedy, in the NHTSA record
Weldon will replace the lights to affected vehicle manufacturers, free of charge. Vehicle manufacturer was notified February 15, 2022. Owners may contact Navistar customer service at 1-800-448-7825. Weldon's number for this recall is 22-04.
Products named: Weldon Back Up Lights.
Report filed by Weldon Division of Akron Brass. Manufacturer campaign number 22-04. Owner notification date in the NHTSA record: .
21E035000Received . 181 units.
Electrical System / Instrument Cluster/Panel
- Defect, in the NHTSA record
Akron Brass Company (Akron Brass) Weldon Division is recalling certain Weldon V-Mux Vista IV Standard LCD displays used for controlling emergency vehicle lighting and HVAC functions. These displays may experience low voltage spikes, and cause the LCD display to lock up or become nonfunctional, due to varying electrical installations.
- Consequence, in the NHTSA record
If the LCD display becomes locked up or non-functional it can delay emergency efforts, which can increase the risk of injury.
- Remedy, in the NHTSA record
Akron Brass will notify owners, and dealers will replace the IV Standard LCD displays, free of charge. The recall began April 28, 2021. Owners may contact Akron Brass customer service at 1-800-228-1161. Akron Brass's number for this recall is TSB 20-10.
Products named: Weldon Vista IV Standard.
Report filed by Weldon Division of Akron Brass. Manufacturer campaign number TSB 20-10. Owner notification date in the NHTSA record: .
20E088000Received . 538 units.
Electrical System
- Defect, in the NHTSA record
Weldon Division of Akron Brass (Akron Brass) is recalling certain Weldon i4G Vivtech control panels, part numbers 10020480 and 10020481. Due to a incorrect processor over voltage, the control panel display may stop working without warning, causing some of the ambulance features to not function.
- Consequence, in the NHTSA record
If the ambulance features do not function, it can cause emergency services to be delayed, increasing the risk of injury or death.
- Remedy, in the NHTSA record
Weldon will notify the purchasers, and dealers for those manufacturers will replace or repair the circuit board in the display, free of charge. The recall began December 8, 2020. Owners may contact Weldon customer service at 1-800-228-1161. Akron Brass's number for this recall is TBS 20-11.
Products named: Weldon 14G Vivtech.
Report filed by Weldon Division of Akron Brass. Manufacturer campaign number TSB 20-12. Owner notification date in the NHTSA record: .
20E078000Received . 990 units.
Electrical System / Instrument Cluster/Panel
- Defect, in the NHTSA record
Akron Brass Company (Akron Brass) Weldon Division is recalling certain Weldon V-Mux Vista IV Standard LCD displays used for controlling emergency vehicle lighting and HVAC functions. These displays may experience low voltage spikes, and cause the LCD display to lock up or become nonfunctional, due to varying electrical installations.
- Consequence, in the NHTSA record
If the LCD display becomes locked up or non-functional it can delay emergency efforts, which can increase the risk of injury.
- Remedy, in the NHTSA record
Akron Brass will notify owners, and dealers will repair or replace the IV Standard LCD displays, free of charge. The recall began October 28, 2020. Owners may contact Akron Brass customer service at 1-800-228-1161. Akron Brass's number for this recall is 20-10.
Products named: Weldon Vista IV Standard.
Report filed by Weldon Division of Akron Brass. Manufacturer campaign number 20-10. Owner notification date in the NHTSA record: .
The campaign number opens the NHTSA record.
Recall campaign: One recall in the NHTSA recall file, with one campaign number. A campaign can name many makes, models and model years.
Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.
Counts
| Component | Campaigns |
|---|---|
| Electrical System | 6 |
| Equipment | 2 |
| Exterior Lighting | 1 |
Products in the campaigns
The product names in the NHTSA file.
- UV800 Display Unit2
- V-Mux Hercules HC Node2
- Vista IV Standard2
- 14G Vivtech1
- 8X16 Input-Output Node1
- Back Up Lights1
Official channels
- NHTSA recall lookupNHTSA shows the recalls of a child seat, a tire or equipment by brand and model.
- NHTSA: report a safety problemThe NHTSA form for a complaint about a vehicle, a tire, a child seat or equipment.
Cite this page
Recall Register. Weldon: equipment recalls. https://recallregister.com/equipment/other/weldon/. Source: NHTSA Office of Defects Investigation, recall files. Data through .
Sources
- Source
- NHTSA Office of Defects Investigation
- Licence
- US government work, public domain
- Recall file through
- 29 Sep 2026
Manufacturers in the recall file: Weldon Division of Akron Brass; Hale Products Inc.
The brand is the make that NHTSA records for the campaign. A campaign that names 2 brands is on the page of each brand. How the register is made. Report an error.
Questions
- Which Weldon products do the campaigns name?
- The NHTSA records have 6 product names for these campaigns. The name in the most campaigns is:
UV800 Display Unit
- How many units does a Weldon equipment campaign have?
- The median Weldon campaign has 860 units. The median of all 2,866 equipment campaigns is 1,677 units.
- Which component do the Weldon campaigns name most often?
- Electrical System, in 6 campaigns. The component is the first component in the NHTSA record of a campaign.