Recall Register

Sci: equipment recalls

NHTSA lists 3 equipment recall campaigns for Sci. NHTSA received the reports from 1995 to 2004. The campaigns have 2,138 units in total. The newest campaign is 04E038000. NHTSA received the report on 20 May 2004.

The defect, the consequence and the remedy on this page are the summaries in the NHTSA recall file. The file names the manufacturer that filed each recall report.

NHTSA recall file through .

Recall campaigns

3 campaigns, newest first. 2,138 units in total.

  1. 04E038000Received . 2,030 units.

    Fuel System, Other / Storage

    Defect, in the NHTSA record
    Certain compressed natural gas fuel containers, model alt823d, p/n 1273147, equipped on certain 2003 and 2004 orion vii buses. The nvg container's pressure relief devices fail to timely and fully activate as required by federal motor vehicle safety standard no. 304, compressed natural gas fuel container integrity.
    Consequence, in the NHTSA record
    In the event of a vehicle fire with the fuel system roof enclosure removed or opened, the fuel container's pressure relief devices may not activate as they are designed to do and the fuel container could rupture and explode. Such an explosion, if it were to occur, could cause serious injuries or death to occupants of the bus or to persons outside the bus.
    Remedy, in the NHTSA record
    Structural composites will replace the pressure relief valve free of charge. Structural composites is expected to notify the owners of affected orion vii buses in june 2004. The recall began february 2005.

    Products named: Orion Vii 2002; Sci ALT823D; Orion Orion Vii 2003.

    Report filed by STRUCTURAL COMPOSITES INDUSTRIES. Owner notification date in the NHTSA record: .

  2. 95E025002Received . 93 units.

    Fuel System, Other / Storage / Tank Assembly / Pressure Relief Devices

    Defect, in the NHTSA record
    Some temperature sensitive triggers were not x-rayed. These triggers could contain internal voids that would make the triggers susceptible to advanced creep causing false activation and venting of the cng.
    Consequence, in the NHTSA record
    Venting of the cng could result in a fire.
    Remedy, in the NHTSA record
    Sci will replace the type III prd with a suitable replace- ment device.

    Products named: Sci Fuel Tank.

    Report filed by STRUCTURAL COMPOSITES.

  3. 95E005002Received . 15 units.

    Fuel System, Other / Storage / Tank Assembly / Pressure Relief Devices

    Defect, in the NHTSA record
    Upon exposure to impurities in the natural gas fuel in cold weather, an internal o-ring on these devices can blister during decompression after "fast-fill" refueling resulting in seal leakage.
    Consequence, in the NHTSA record
    Internal damage to the o-ring seal could cause a release of cng. If cng were released to the environment and an ignition source were present, a fire could occur.
    Remedy, in the NHTSA record
    Sci will replace recalled units with new devices that are not susceptible to o-ring damage from non-methane components of the gas supply when the devices are developed.

    Products named: Sci Alt 620N 1994; Sci Alt 584N 1994; Sci Alt 506N 1994; Sci Alt 619N 1994.

    Report filed by STRUCTURAL COMPOSITES.

The campaign number opens the NHTSA record.

Recall campaign: One recall in the NHTSA recall file, with one campaign number. A campaign can name many makes, models and model years.

Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.

Counts

Sci equipment campaigns, by the year NHTSA received the report. The largest year is 1995, with 2 campaigns.

Products in the campaigns

The product names in the NHTSA file.

  • Alt 506N1
  • Alt 584N1
  • Alt 619N1
  • Alt 620N1
  • ALT823D1
  • Fuel Tank1

Official channels

Cite this page

Recall Register. Sci: equipment recalls. https://recallregister.com/equipment/other/sci/. Source: NHTSA Office of Defects Investigation, recall files. Data through .

Sources

Source
NHTSA Office of Defects Investigation
Licence
US government work, public domain
Recall file through
29 Sep 2026

Manufacturers in the recall file: STRUCTURAL COMPOSITES; STRUCTURAL COMPOSITES INDUSTRIES.

The brand is the make that NHTSA records for the campaign. A campaign that names 2 brands is on the page of each brand. How the register is made. Report an error.

Questions

Which Sci products do the campaigns name?
The NHTSA records have 6 product names for these campaigns. The name in the most campaigns is: Alt 506N
How many units does a Sci equipment campaign have?
The median Sci campaign has 93 units. The median of all 2,866 equipment campaigns is 1,677 units.
Which component do the Sci campaigns name most often?
Fuel System, Other, in 3 campaigns. The component is the first component in the NHTSA record of a campaign.