Mirada: equipment recalls
NHTSA lists 4 equipment recall campaigns for Mirada. NHTSA received the reports in 1995. The campaigns have 28,105 units in total. The newest campaign is 95E025000. NHTSA received the report on 16 Jun 1995.
The defect, the consequence and the remedy on this page are the summaries in the NHTSA recall file. The file names the manufacturer that filed each recall report.
NHTSA recall file through .
Recall campaigns
4 campaigns, newest first. 28,105 units in total.
95E025000Received . 15,590 units.
Fuel System, Other / Storage / Tank Assembly / Pressure Relief Devices
- Defect, in the NHTSA record
Some temperature sensitive triggers were not x-rayed. These triggers could contain internal voids that would make the triggers susceptible to advanced creep causing false activation and venting of the cng.
- Consequence, in the NHTSA record
Venting of the cng could result in a fire.
- Remedy, in the NHTSA record
Mirada will replace the pressure relief devices with the newer design "generation 2.5" pressure relief devices.
Products named: Mirada B-51336; Mirada B-51459; Mirada B-51363; Mirada B-51298; Mirada B-51299-1; Mirada B-51487; Mirada B-51464; Mirada B-51308; Mirada B-51299; Mirada B-51339; Mirada B-51498; Mirada B-51506, and 10 more.
Report filed by MIRADA CONTROLS, INC.. Owner notification date in the NHTSA record: .
95E014000Received . 1,000 units.
Fuel System, Other / Storage / Tank Assembly / Pressure Relief Devices
- Defect, in the NHTSA record
Non-stainless steel balls (chrome plated steel) in the thermal trigger of the pressure relief device have corroded causing false thermal activation.
- Consequence, in the NHTSA record
This condition can cause a sudden release of cng. If cng were released to the environment and an ignition source were present, a fire could occur.
- Remedy, in the NHTSA record
Mirada will replace these pressure relief devices with devices which have stainless steel balls.
Products named: Mirada B-51300.
Report filed by MIRADA CONTROLS, INC..
95E005000Received . 5,515 units.
Fuel System, Other / Storage / Tank Assembly / Pressure Relief Devices
- Defect, in the NHTSA record
Upon exposure to impurities in the natural gas fuel in cold weather, an internal o-ring on these devices can blister during decompression after "fast-fill" refueling resulting in seal leakage.
- Consequence, in the NHTSA record
Internal damage to the o-ring seal could cause a release of cng. If cng were released to the environment and an ignition source were present, a fire could occur.
- Remedy, in the NHTSA record
Dealers will replace recalled units with new devices that are not susceptible to o-ring damage from non-methane components of the gas supply when the devices are developed.
Products named: Mirada B-51300.
Report filed by MIRADA CONTROLS, INC..
95E007000Received . 6,000 units.
Fuel System, Other / Storage / Tank Assembly / Pressure Relief Devices
- Defect, in the NHTSA record
The torque plug assembled into the pressure relief device was not welded or pinned in production. The tightening or torquing of the pressure relief device as installed on the vehicle could cause damage to the internal parts of the device.
- Consequence, in the NHTSA record
Internal damage to the device could cause a sudden release of cng. If cng were released to the environment and an ignition source were present, a fire could occur.
- Remedy, in the NHTSA record
Mirada will replace these pressure relief devices with devices which have the torque plug welded or pinned.
Products named: Mirada B-51363; Mirada B-51336; Mirada B-51298; Mirada B-51468; Mirada B-51440; Mirada B-51298-1; Mirada B-51458; Mirada B-51465; Mirada B-51469; Mirada B-51386.
Report filed by MIRADA CONTROLS, INC.. Owner notification date in the NHTSA record: .
The campaign number opens the NHTSA record.
Recall campaign: One recall in the NHTSA recall file, with one campaign number. A campaign can name many makes, models and model years.
Units: The number of vehicles or products that a recall can include. The manufacturer or the firm reports the number to the agency.
Counts
Products in the campaigns
The product names in the NHTSA file.
- B-513003
- B-512982
- B-51298-12
- B-513362
- B-513632
- B-513862
- B-514402
- B-514652
- B-514682
- B-514692
- B-512461
- B-51246-31
- B-512991
- B-51299-11
- B-513081
- B-513391
- B-514581
- B-514591
- B-514641
- B-514871
- B-514981
- B-515061
- B-515721
Official channels
- NHTSA recall lookupNHTSA shows the recalls of a child seat, a tire or equipment by brand and model.
- NHTSA: report a safety problemThe NHTSA form for a complaint about a vehicle, a tire, a child seat or equipment.
Cite this page
Recall Register. Mirada: equipment recalls. https://recallregister.com/equipment/other/mirada/. Source: NHTSA Office of Defects Investigation, recall files. Data through .
Sources
- Source
- NHTSA Office of Defects Investigation
- Licence
- US government work, public domain
- Recall file through
- 29 Sep 2026
Manufacturers in the recall file: MIRADA CONTROLS, INC..
The brand is the make that NHTSA records for the campaign. A campaign that names 2 brands is on the page of each brand. How the register is made. Report an error.
Questions
- Which Mirada products do the campaigns name?
- The NHTSA records have 23 product names for these campaigns. The name in the most campaigns is:
B-51300
- How many units does a Mirada equipment campaign have?
- The median Mirada campaign has 6,000 units. The median of all 2,866 equipment campaigns is 1,677 units.
- Which component do the Mirada campaigns name most often?
- Fuel System, Other, in 4 campaigns. The component is the first component in the NHTSA record of a campaign.