Recall Register

Food, drugs, devices › Roche Diagnostics Corporation

Device recall: Elecsys BRAHMS PCT Immunoassay for the in vitro quantitative determination of PCT (procalcitonin) in human serum and pla

FDA enforcement event 79462 · Class II · initiated 22 Dec 2017 · status Terminated · terminated 5 Apr 2019

DeviceVoluntary: Firm initiated1 product recordIndianapolis, IN

FDA enforcement event 79462 is a device recall by Roche Diagnostics Corporation of Indianapolis, IN, initiated 22 Dec 2017 and classified Class II, with 1 product record.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 93% of the 1,091 device enforcement events initiated in 2017 carry the same class.

Status: Terminated, terminated 5 Apr 2019. Initiation: voluntary: firm initiated. Roche Diagnostics Corporation has 26 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Roche Diagnostics Corporation, Indianapolis, IN.

Reason for recall

"Product exhibits a decreased recovery of patient samples on the cobas e 801 module compared to the MODULAR ANALYTICS E 170, cobas e 411, 601, and 602 analyzers."

Distribution

"US Distribution in states of: CA, FL and IN."

Product records

Recall numberProductQuantityClassStatusReport date
Z-1311-2018Elecsys BRAHMS PCT Immunoassay for the in vitro quantitative determination of PCT (procalcitonin) in human serum and plasma (K2 and K3 EDTA, Li-Heparin).47Class IITerminated11 Apr 2018

Context

93%of 2017 device events are Class II1,091 events that year
1product record in this eventfirm median: 1
26events on this register for the firm

Other enforcement events for Roche Diagnostics Corporation

InitiatedProduct (first record)TypeClassRecords
3 Jun 2019The Tina-quant lgA Gen.2 is an immunoturbidimetric assay. Anti-lgA antibodies react with antigen in the sample to form aDeviceClass II1
4 Apr 2019cobas p 501 post-analytical units, Part Number 05158494001. For diagnostic sample storage and retrieval.DeviceClass III2
18 Mar 2019Albumin BCP Product Usage: ALBP is an in vitro test used for the quantitative determination of albumin in human serum anDeviceClass II1
15 Mar 2019cobas e 801 immunoassay analyzerDeviceClass II1
4 Feb 2019Cobas¿ infinity central lab IT solution Material Number: 07154003001 Calculator/Data Processing Module, For Clinical UseDeviceClass II1
17 Dec 2018Bilirubin Total Gen.3, Cat. Nos. 05795397190, 05795419190, 05795320160, 05795338160, 05795346160 ***added as of 5/10/19*DeviceClass II3
17 Dec 2018Anti-HAV IgM test System, Material No. 11820591160 Product Usage: The Roche Elecsys Anti-HAV IgM immunoassay is used forDeviceClass II1
14 Dec 2018COBAS INTEGRA 400 plus analyzer used in the following assays: a)Tina-quant Apolipoprotein A-1 ver.2 Catalog Number: 0303DeviceClass II2
24 Sep 2018Roche Diagnostics URISYS 1100 Urine Analyzer Part Number: 03617556001 Product Usage: The URISYS 1100 Urine Analyzer is aDeviceClass II1
13 Sep 2018CoaguChek¿ XS System Prothrombin time test: CoaguChek XS PT Test 2X24 Strips, Catalog Number: 04625315160; CoaguChek XS DeviceClass I1

All 26 events for Roche Diagnostics Corporation

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Product exhibits a decreased recovery of patient samples on the cobas e 801 module compared to the MODULAR ANALYTICS E 170, cobas e 411, 601, and 602 analyzers."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "US Distribution in states of: CA, FL and IN."

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 5 Apr 2019. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.