Device recall: AU480 Chemistry Analyzers, Reference No. B28624 The AU series are automated, clinical chemistry analyzers that measure a

FDA enforcement event 74568 · Class II · initiated 30 Jul 2015 · status Terminated · terminated 15 Feb 2017

DeviceVoluntary: Firm initiated3 product recordsBrea, CA

FDA enforcement event 74568 is a device recall by Beckman Coulter Inc. of Brea, CA, initiated 30 Jul 2015 and classified Class II, with 3 product records.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 91% of the 1,153 device enforcement events initiated in 2015 carry the same class.

Status: Terminated, terminated 15 Feb 2017. Initiation: voluntary: firm initiated. Beckman Coulter Inc. has 216 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Beckman Coulter Inc., Brea, CA.

Reason for recall

"Beckman coulter has received complaints regarding leaking and cracked C cups. When the cup cracks, coolant can leak onto the connectors of the Printed Circuit Boards (PCB) in the analyzer, resulting in a short-circuit causing the instrument to go into a stop mode."

Distribution

"Worldwide Distribution - US (nationwide (including Guam and Puerto Rico), and Internationally to Albania, Algeria, Australia, Austria, Bangladesh, Belarus, Belgium, Bolivia, Bosnia and Herzegovina,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-2308-2016AU480 Chemistry Analyzers, Reference No. B28624 The AU series are automated, clinical chemistry analyzers that measure analytes in patient samples (serum, plasma, urine, CSF) in combination with appropriate reagents, calibrators, quality, control (QC) materials, and other accessories.3,355 units total (617 units in US)Class IITerminated10 Aug 2016
Z-2309-2016AU680 Chemistry Analyzers, Reference No. B04779 The AU series are automated, clinical chemistry analyzers that measure analytes in patient samples (serum, plasma, urine, CSF) in combination with appropriate reagents, calibrators, quality, control (QC) materials, and other accessories.3,084 units total (713 units in US)Class IITerminated10 Aug 2016
Z-2310-2016AU5800 Chemistry Analyzers, Reference No. A98352 The AU series are automated, clinical chemistry analyzers that measure analytes in patient samples (serum, plasma, urine, CSF) in combination with appropriate reagents, calibrators, quality, control (QC) materials, and other accessories.2,130 units total (588 units in US)Class IITerminated10 Aug 2016

Context

91%of 2015 device events are Class II1,153 events that year
3product records in this eventfirm median: 1
216events on this register for the firm

Other enforcement events for Beckman Coulter Inc.

InitiatedProduct (first record)TypeClassRecords
15 Jul 2026Beckman Coulter DxC 500i Clinical Analyzer Modules using software version 1.5 or lower: 1) DxC 500 AU Module w/ISE, DxC DeviceClass II2
26 Jun 2026REF # D23352, MicroScan LabPro V5.03 Panel Update 11 (US), Electronic installed on the following instruments: - B1018-28DeviceClass II2
16 Mar 2026Access Total T4 Calibrator, Catalog No. 33805DeviceClass II1
23 Dec 2025CellMek SPS Sample Preparation System, REF: C44603, with softwareDeviceClass II1
26 Nov 2025Beckman Coulter UniCel Dxl 600, Part numbers: A71460, A71461, A30260; Immunoassay Method, Troponin SubunitDeviceClass II2
10 Nov 2025COULTER DxH Diluent, REF 628017 COULTER DxH ECO Diluent REF C67250 For use as an isotonic buffered diluent in conjunctioDeviceClass II1
7 Nov 2025Access 2 Reaction Vessels, individual, disposable, plastic tubes used to process patient, quality control and calibratioDeviceClass II1
1 Oct 2025Beckman Coulter UniCel DxI 600, Part Numbers: A71460, A30260; Photometric Chemistry AnalyzerDeviceClass II2
22 Sep 2025DxFLEX Flow Cytometer Catalog Number C78500 UDI-DI code: 15099590754013 The DxFLEX Flow Cytometer is intended for use asDeviceClass II1
19 Sep 2025DxC 500i Clinical Analyzer Modules, DxC 500 AU Module w/ISE, DxC 500i (Part Number C63522), DxC 500 AU Module, DxC 500i DeviceClass II2

All 216 events for Beckman Coulter Inc.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Beckman coulter has received complaints regarding leaking and cracked C cups. When the cup cracks, coolant can leak onto the connectors of the Printed Circuit Boards (PCB) in the analyzer, resulting in a short-circuit causing the instrument to go into a stop mode."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution - US (nationwide (including Guam and Puerto Rico), and Internationally to Albania, Algeria, Australia, Austria, Bangladesh, Belarus, Belgium, Bolivia, Bosnia and Herzegovina,…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 15 Feb 2017. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.