Device recall: UniCel DxH 800 Coulter Cellular Analysis System, Part No. 629029, B24465, and B24802. Used for in vitro diagnostic use i

FDA enforcement event 67058 · Class II · initiated 8 Nov 2013 · status Terminated · terminated 25 Dec 2014

DeviceVoluntary: Firm initiated4 product recordsBrea, CA

FDA enforcement event 67058 is a device recall by Beckman Coulter Inc. of Brea, CA, initiated 8 Nov 2013 and classified Class II, with 4 product records.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 90% of the 1,236 device enforcement events initiated in 2013 carry the same class.

Status: Terminated, terminated 25 Dec 2014. Initiation: voluntary: firm initiated. Beckman Coulter Inc. has 216 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Beckman Coulter Inc., Brea, CA.

Reason for recall

"Beckman Coulter is recalling the UniCel DxH800 and UniCel DxH600 Coulter Analysis Systems because the optical degradation may potentially cause a delay in reporting results for nucleated red blood cells (nRBC), automated white blood cell differential and the reticulocyte."

Distribution

"Worldwide Distribution -- US, Canada, Australia, China, Belgium, Brunei Darssalam, Colombia, Croatia, Czech Republic, France, Germany, Gibraltar, Greece, Hong Kong, Hungary, India, Ireland, Italy,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-1828-2014UniCel DxH 800 Coulter Cellular Analysis System, Part No. 629029, B24465, and B24802. Used for in vitro diagnostic use in screening patient populations found in clinical laboratories.2,874 units total (1696 units in US)Class IITerminated2 Jul 2014
Z-1829-2014UniCel DxH 600 Coulter Cellular Analysis System, Part No. B23858. Used for in vitro diagnostic use in screening patient populations found in clinical laboratories.164 units total (106 units in US)Class IITerminated2 Jul 2014
Z-1830-2014Coulter DxH Cleaner 5L, Part No. 628022. For use on UniCel DxH Systems for components that come in contact with blood samples.768 units total (6 units in US)Class IITerminated2 Jul 2014
Z-1831-2014Coulter DxH Cleaner 10L, Part No. 628023. For use on UniCel DxH Systems for components that come in contact with blood samples.12,924 units total (9,733 units in US)Class IITerminated2 Jul 2014

Context

90%of 2013 device events are Class II1,236 events that year
4product records in this eventfirm median: 1
216events on this register for the firm

Other enforcement events for Beckman Coulter Inc.

InitiatedProduct (first record)TypeClassRecords
15 Jul 2026Beckman Coulter DxC 500i Clinical Analyzer Modules using software version 1.5 or lower: 1) DxC 500 AU Module w/ISE, DxC DeviceClass II2
26 Jun 2026REF # D23352, MicroScan LabPro V5.03 Panel Update 11 (US), Electronic installed on the following instruments: - B1018-28DeviceClass II2
16 Mar 2026Access Total T4 Calibrator, Catalog No. 33805DeviceClass II1
23 Dec 2025CellMek SPS Sample Preparation System, REF: C44603, with softwareDeviceClass II1
26 Nov 2025Beckman Coulter UniCel Dxl 600, Part numbers: A71460, A71461, A30260; Immunoassay Method, Troponin SubunitDeviceClass II2
10 Nov 2025COULTER DxH Diluent, REF 628017 COULTER DxH ECO Diluent REF C67250 For use as an isotonic buffered diluent in conjunctioDeviceClass II1
7 Nov 2025Access 2 Reaction Vessels, individual, disposable, plastic tubes used to process patient, quality control and calibratioDeviceClass II1
1 Oct 2025Beckman Coulter UniCel DxI 600, Part Numbers: A71460, A30260; Photometric Chemistry AnalyzerDeviceClass II2
22 Sep 2025DxFLEX Flow Cytometer Catalog Number C78500 UDI-DI code: 15099590754013 The DxFLEX Flow Cytometer is intended for use asDeviceClass II1
19 Sep 2025DxC 500i Clinical Analyzer Modules, DxC 500 AU Module w/ISE, DxC 500i (Part Number C63522), DxC 500 AU Module, DxC 500i DeviceClass II2

All 216 events for Beckman Coulter Inc.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Beckman Coulter is recalling the UniCel DxH800 and UniCel DxH600 Coulter Analysis Systems because the optical degradation may potentially cause a delay in reporting results for nucleated red blood cells (nRBC), automated white blood cell differential and the reticulocyte."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution -- US, Canada, Australia, China, Belgium, Brunei Darssalam, Colombia, Croatia, Czech Republic, France, Germany, Gibraltar, Greece, Hong Kong, Hungary, India, Ireland, Italy,…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 25 Dec 2014. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.