Recall Register

Food, drugs, devices › Ormco/Sybronendo

Device recall: Brand Name: Vector TAS 8mm Screw. The Device Listing Number is E670535. Vector T AS 8mm Screw is intended to provide a f

FDA enforcement event 66173 · Class II · initiated 12 Jul 2013 · status Terminated · terminated 11 Sep 2014

DeviceVoluntary: Firm initiated1 product recordGlendora, CA

Ormco/Sybronendo (Glendora, CA) initiated this device recall on 12 Jul 2013; FDA lists 1 product record under event 66173, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 90% of the 1,236 device enforcement events initiated in 2013 carry the same class.

Status: Terminated, terminated 11 Sep 2014. Initiation: voluntary: firm initiated. Ormco/Sybronendo has 14 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Ormco/Sybronendo, Glendora, CA.

Reason for recall

"Ormco Corporation is voluntarily recalling one lot of 8 MM Vector TAS Screws because some screws of this lot were machined undersized at the top of the threads may potentially cause a weakening of the screw. Use of the undersized product may result in breakage of the screw during insertion or removal when torqued, possibly requiring surgical removal of any remaining pieces."

Distribution

"Worldwide Distribution - USA (nationwide) including the countries of Canada, Australia, New Zealand, EU and ROW consignees."

Product records

Recall numberProductQuantityClassStatusReport date
Z-2194-2013Brand Name: Vector TAS 8mm Screw. The Device Listing Number is E670535. Vector T AS 8mm Screw is intended to provide a fixed anchorage point for attachment of orthodontic appliances to facilitate the orthodontic movement of teeth. It is used temporarily and removed after orthodontic treatment has been completed. It…4,786Class IITerminated18 Sep 2013

Context

90%of 2013 device events are Class II1,236 events that year
1product record in this eventfirm median: 1
14events on this register for the firm

Other enforcement events for Ormco/Sybronendo

InitiatedProduct (first record)TypeClassRecords
17 Jan 2020SnapLink, Ref Part No. 438-2190, L6R SnapLink, Slot .022, TQ--28, Ang +2, Rot +2, Qty 10, Made in Mexico, CE 0086, Rx OnDeviceClass II2
14 Jan 2020Ormco Damon Q2 Orthodontic Metal Bracket, Part No. 491-9834, L3R Hi Tq Hook, Tq +13 degrees, Rx. Manufactured by Ormco CDeviceClass II1
27 Dec 2017Elements Obturation Unit (EOU) used with respective Buchanan Heat Pluggers Device is an endodontic root canal plugger. IDeviceClass II1
31 Aug 2016Sealapex Xpress, Part No. 33639 The brand name of the device is Sealapex Xpress, a root canal filling resin. Sealapex XpDeviceClass II1
8 Feb 2016TF Adaptive Gutta Percha Point Size SM3 50pk, Part No. 815-1541 Intended to fill a endontontically obturated root canal DeviceClass II1
4 Nov 2015Copper NiTi Preformed Archwires; Copper NiTi 40 BAF .016X.022 LO Pk10, Part No. 211-0952. Intended to provide tooth moveDeviceClass II1
25 Mar 2014Spirit MB Bracket, UR Central +14T +5A.018, Part Number 494-0110, Lot Number 081351013. Product Usage: An orthodontic brDeviceClass II1
25 Mar 2014Titanium Orthos Brackets, an orthodontic bracket. 022 +9/+9/0, Part Number 449-6212, Lot Number 121359169. A fixed attacDeviceClass II1
8 Mar 2013Bracket Buccal Tube U7L DB/UL22 Roth MT HK 0/-14/0 Product Usage: Bracket Buccal Tubes are intended to hold in orthodontDeviceClass II1
17 Jan 2013SybronEndo Elements Obturation Unit; REF 973-0322; SN 91-1234; 2005-10; SybronEndo, 1332 S. Lone Hill Ave. Glendora, CA DeviceClass II2

All 14 events for Ormco/Sybronendo

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Ormco Corporation is voluntarily recalling one lot of 8 MM Vector TAS Screws because some screws of this lot were machined undersized at the top of the threads may potentially cause a weakening of the screw. Use of the undersized product may result in breakage of the screw during insertion or removal when torqued, possibly requiring surgical removal of any remaining pieces."

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution - USA (nationwide) including the countries of Canada, Australia, New Zealand, EU and ROW consignees."

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 11 Sep 2014. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.