Device recall: Optilock 2.7 mm Screw Inserter. Intended Use: The OptiLock Upper Extremity Plating System is intended for fixation of fr

FDA enforcement event 63073 · Class II · initiated 23 Aug 2012 · status Terminated · terminated 27 Aug 2013

DeviceVoluntary: Firm initiated2 product recordsWarsaw, IN

Biomet, Inc. (Warsaw, IN) initiated this device recall on 23 Aug 2012; FDA lists 2 product records under event 63073, classified Class II.

FDA defines Class II as a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. 88% of the 823 device enforcement events initiated in 2012 carry the same class.

Status: Terminated, terminated 27 Aug 2013. Initiation: voluntary: firm initiated. Biomet, Inc. has 84 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Biomet, Inc., Warsaw, IN.

Reason for recall

"Field complaints indicate that recent shipments of the 14-400795 and 36505 drivers do not properly mate ("lock") into some of the specified screw heads. Drivers near MMC (Maximum Material Condition) or that are misshapen may not properly mate with screws at MMC. Design dimensions and tolerances of the drivers are not properly specified to prevent an incorrect fit between the drivers and the screw"

Distribution

"Worldwide Distribution-USA (nationwide) including the states of AL, GA, MT, TA, AZ, WA, CA, TA, IN, NY, NJ, VA, MA, MI, MD, PA, KY, NC, UT, NH, FL, OK, CO, LA, OH, MO and SD, and the countries of…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-2485-2012Optilock 2.7 mm Screw Inserter. Intended Use: The OptiLock Upper Extremity Plating System is intended for fixation of fractures and osteotomies. The System is intended for fractures and fracture dislocations, osteotomies and non-unions of the proximal humerus, particularly in osteopenic bone. The System is intended…268 units totalClass IITerminated10 Oct 2012
Z-2486-2012Optilock T15 AO Driver (3.5mm). Intended Use: The OptiLock Upper Extremity Plating System is intended for fixation of fractures and osteotomies. The System is intended for fractures and fracture dislocations, osteotomies and non-unions of the proximal humerus, particularly in osteopenic bone. The System is intended…363 unitsClass IITerminated10 Oct 2012

Context

88%of 2012 device events are Class II823 events that year
2product records in this eventfirm median: 1
84events on this register for the firm

Other enforcement events for Biomet, Inc.

InitiatedProduct (first record)TypeClassRecords
1 Jul 2026Intramedullary Bone Saw Blade Assembly Model/Catalog Number: 475620 Product Description: Intramedullary Bone Saw Blade ADeviceClass II5
23 Sep 2025BIOMET ZipTight, Acute AC Joint Implant, Single Ziploop , Model/Catalog Number: 904834; Fixation System for AC Joint RepDeviceClass II1
9 Sep 2025Juggerknot Mini Soft Anchors, Model/Catalog Number: 912080DeviceClass II1
21 Oct 2024JuggerLoc/ToggleLoc 2.9mm Drill Guide, Model number 110027357DeviceClass II1
17 May 2024RingLoc Bi-Polar Hip System Acetabular Cup, 41 mm Outer Diameter - Used in hip hemi-arthroplasty Item Number: 11-165206DeviceClass II1
13 Mar 2024Vanguard Knee System AS Tibial Bearing / DCM ArCom, 12 MM X 75 MM; Model Number 189082. The product is placed into a foiDeviceClass II1
2 Nov 2023Biolox Ceramic Option Head Zimmer 12/14 40mm -3, Item Number 00-8777-040-01DeviceClass II2
9 Oct 2023Compress Device Segmental Anchor Plug, 10 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previDeviceClass II19
6 Feb 2023G7 Acetabular System, Dual Mobility Acetabular Liner, 40 mm, Size D, Model Number 110024462DeviceClass II1
29 Dec 2022(1) Vanguard Knee System PS Open Box Femoral; Right; 60 mm. Intended for knee joint replacement prostheses. Item Number:DeviceClass II2

All 84 events for Biomet, Inc.

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Field complaints indicate that recent shipments of the 14-400795 and 36505 drivers do not properly mate ("lock") into some of the specified screw heads. Drivers near MMC (Maximum Material Condition) or that are misshapen may not properly mate with screws at MMC. Design dimensions and tolerances of the drivers are not properly specified to prevent an incorrect fit between the drivers and the screw"

What does Class II mean?

FDA classifies recalls by relative degree of health hazard. Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution-USA (nationwide) including the states of AL, GA, MT, TA, AZ, WA, CA, TA, IN, NY, NJ, VA, MA, MI, MD, PA, KY, NC, UT, NH, FL, OK, CO, LA, OH, MO and SD, and the countries of…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 27 Aug 2013. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.