Food, drugs, devices › Atrium Medical Corporation

Device recall: Atrium Advanta V12 Covered Stent System (OUS only). Product Code/Part Number: 85320 85321 85322 85323 85324 85325 85326

FDA enforcement event 89852 · Class I · initiated 3 Mar 2022 · status Ongoing

DeviceVoluntary: Firm initiated2 product recordsMerrimack, NH

FDA enforcement event 89852 is a device recall by Atrium Medical Corporation of Merrimack, NH, initiated 3 Mar 2022 and classified Class I, with 2 product records.

FDA defines Class I as a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death. 8% of the 839 device enforcement events initiated in 2022 carry the same class.

Status: Ongoing. Initiation: voluntary: firm initiated. Atrium Medical Corporation has 29 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Atrium Medical Corporation, Merrimack, NH.

Reason for recall

"Firm has observed increased rate of customer complaints related to separation of the balloon or catheter hub from the delivery catheter during delivery system withdrawal causing procedural delay and possible administration of additional anesthesia and contrast which may impact patients' renal function. Potential harms include occlusion or embolism and associated response, with specific outcomes…"

Distribution

"Foreign: Australia Austria Bahrain Belgium Bosnia-Herzegovina Brazil Bulgaria Canada Chile Colombia Costa Rica Cyprus Czech Republic Denmark Ecuador Egypt El Salvador Estonia Finland France Germany…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-1076-2022Atrium Advanta V12 Covered Stent System (OUS only). Product Code/Part Number: 85320 85321 85322 85323 85324 85325 85326 85327 85328 85329 85330 85331 85332 85333 85334 85335 85336 85337 85338 85339 85340 85341 85342 85343 85344 85345 85350 85351 85352 85353 85354 85355 85360 85361 85364 85365 85388 85389 85390 85391…105,968 unitsClass IOngoing25 May 2022
Z-1077-2022iCast Covered Stent System Product Code/Part Number: 85400 85401 85402 85403 85404 85405 85406 85407 85408 85409 85410 85411 85412 85413 85414 85415 85416 85417 85418 85419 85420 85424 85440 85441 85442 85443 85444 85445 85450 85451 85452 85453 85454 85455 Product Code/UDI /Description: 85400 00650862854008 iCAST…68812 unitsClass IOngoing25 May 2022

Context

8%of 2022 device events are Class I839 events that year
2product records in this eventfirm median: 1
29events on this register for the firm

Other enforcement events for Atrium Medical Corporation

InitiatedProduct (first record)TypeClassRecords
7 Aug 2026Getinge PVC Thoracic Catheter, Soft PVC Straight, 10 per Case; Size(Model Number): 1. 16FR(8016), 2. 24FR(8024), 3. 28FRDeviceClass II3
9 Sep 2024iCast Covered Stent, 6MMx16MMx120CM, Model Number 42616DeviceClass II1
3 May 2024ADVANTA VXT, 5X40, 1GDS, NH, STR-SW. Single-Ended Slider. Vascular graftDeviceClass II68
1 Nov 2023Atrium Oasis Drain Single W / AC, Part No. 3600-100DeviceClass II1
29 Sep 2023Atrium Firm PVC Thoracic Catheter 36FR Straight, part number 15036.DeviceClass II1
21 Sep 2023Atrium Advanta V12 Covered Stent System, 10mm x 59mm x 80cm (OUS)-Indicated for restoring and improving the patency of tDeviceClass II1
18 Sep 2023Ocean Water Seal Chest Drains (Ocean): Products REF Number Product Name (1)2002-000 DRAIN, OCEAN SINGLE W/AC,S; (2)2002-DeviceClass II3
5 Sep 2023Atrium Oasis Dry Suction Water Seal Chest Drain, Part Number: 3600-100, DRAIN, OASIS SINGLE W/AC, 3600 SINGLE COLLECTIONDeviceClass II2
1 Mar 2023Atrium Pneumostat Chest Drain Valve, Part Number 16100DeviceClass II2
18 Oct 2022Atrium Ocean Wet Suction Water Seal Chest Drain- Product Code: 2002-000DeviceClass II1

All 29 events for Atrium Medical Corporation

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "Firm has observed increased rate of customer complaints related to separation of the balloon or catheter hub from the delivery catheter during delivery system withdrawal causing procedural delay and possible administration of additional anesthesia and contrast which may impact patients' renal function. Potential harms include occlusion or embolism and associated response, with specific outcomes…"

What does Class I mean?

FDA classifies recalls by relative degree of health hazard. Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.

Where was the product distributed?

FDA's distribution pattern field reads: "Foreign: Australia Austria Bahrain Belgium Bosnia-Herzegovina Brazil Bulgaria Canada Chile Colombia Costa Rica Cyprus Czech Republic Denmark Ecuador Egypt El Salvador Estonia Finland France Germany…"

Is the recall still ongoing?

FDA lists the status as Ongoing. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.