Device recall: QUADROX-i Neonatal without integrated arterial filter and VHK 11000 (VKMO 10000-USA#QUADROX-i Neo.+Reservoir), Part Numb

FDA enforcement event 81382 · Class I · initiated 25 Oct 2018 · status Terminated · terminated 5 Jun 2020

DeviceVoluntary: Firm initiated2 product recordsWayne, NJ

FDA enforcement event 81382 is a device recall by Maquet Cardiovascular Us Sales, Llc of Wayne, NJ, initiated 25 Oct 2018 and classified Class I, with 2 product records.

FDA defines Class I as a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death. 4% of the 1,074 device enforcement events initiated in 2018 carry the same class.

Status: Terminated, terminated 5 Jun 2020. Initiation: voluntary: firm initiated. Maquet Cardiovascular Us Sales, Llc has 40 enforcement events on this register, with a median of 1 product record per event.

Recall classification reflects the relative degree of health hazard. Text in quotation marks is FDA's. openFDA export dated 28 Sep 2026.

Recalling firm

Maquet Cardiovascular Us Sales, Llc, Wayne, NJ.

Reason for recall

"There is a potential for blood leakage at the blood inlet connector when using the reducing screw adapter 1/4 x 3/16 that may result in clinically relevant loss of prime before patient connection or blood loss during patient connection."

Distribution

"Worldwide Distribution: US (nationwide) to states of: AZ, CA, FL, IA, LA, NC, and TX and countries of: Canada, Argentina, Brazil, Chile, Colombia, Mexico, Uruguay, United Arab Emirates, Belgium,…"

Product records

Recall numberProductQuantityClassStatusReport date
Z-0436-2019QUADROX-i Neonatal without integrated arterial filter and VHK 11000 (VKMO 10000-USA#QUADROX-i Neo.+Reservoir), Part Number 701055120 The membrane oxygenator QUADROXi Neonatal is intended for use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery.490 total in USClass ITerminated5 Dec 2018
Z-0437-2019QUADROX-i Neonatal with integrated arterial filter and VHK 11000 (VKMO 11000-USA#QUADROX-i Neo.+Reservoir), Part Number 701055207 The membrane oxygenator QUADROXi Neonatal is intended for use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery.490 total in USClass ITerminated5 Dec 2018

Context

4%of 2018 device events are Class I1,074 events that year
2product records in this eventfirm median: 1
40events on this register for the firm

Other enforcement events for Maquet Cardiovascular Us Sales, Llc

InitiatedProduct (first record)TypeClassRecords
20 Nov 2020HLS Set Advanced Model Name: BEQ-HLS 5050 USA; HLS Set Advanced 5.0, Product Code/Part Number: 70105.2797 - Product UsagDeviceClass II2
30 Sep 2020Blood Monitoring Unit (BMU 40), model no. 701040852 - Product Usage: is to monitor blood parameters during cardiopulmonaDeviceClass II1
24 Sep 2020Yuno Mobile Operating Table - Product Usage: Intended for support and position the patient immediately before, during anDeviceClass II2
7 Aug 2020Maquet/Getinge Rotaflow System Console US (115 V / 60 Hz) - Product Usage: Instructions for Use - Centrifugal Pump SysteDeviceClass III1
18 Jun 2020Holder HKHZ 19 for use with Quadrox-i and Quadrox-iD Neonatal / Pediatric Oxygenators, Model Number: 701047495 - ProductDeviceClass II1
20 Feb 2020Avalon Elite Vascular Access Kit, Model No. 70106.3540, UDI 04037691831039DeviceClass II1
10 Feb 2020Getinge 88-Series-washer disinfectors intended for cleaning, disinfection and drying Model Number: 88-5 Part Number: 88-DeviceClass II1
16 Jan 2020Getinge 46-Series Washer Disinfector Model # 46-4, Part Number:46-4-502 Product Usage: Used in facilities such as CentraDeviceClass III2
3 Dec 2019Maquet Cardiopulmonary (MCP)/Getinge ROTAFLOW Drive, Model Number 701022161. The device is a component of the ROTAFLOW SDeviceClass II1
11 Jul 2019Maquet Cardiopulmonary (MCP)/Getinge HLS Set Advanced 7.0. Model Number BEQ-HLS-7050 USA, Part Number 701052794DeviceClass II1

All 40 events for Maquet Cardiovascular Us Sales, Llc

Questions and answers

Why was this device recalled?

FDA's record gives the reason for recall as: "There is a potential for blood leakage at the blood inlet connector when using the reducing screw adapter 1/4 x 3/16 that may result in clinically relevant loss of prime before patient connection or blood loss during patient connection."

What does Class I mean?

FDA classifies recalls by relative degree of health hazard. Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.

Where was the product distributed?

FDA's distribution pattern field reads: "Worldwide Distribution: US (nationwide) to states of: AZ, CA, FL, IA, LA, NC, and TX and countries of: Canada, Argentina, Brazil, Chile, Colombia, Mexico, Uruguay, United Arab Emirates, Belgium,…"

Is the recall still ongoing?

FDA lists the status as Terminated; the termination date is 5 Jun 2020. "Terminated" means FDA has determined that all reasonable efforts to remove or correct the product have been made.

Where does this data come from?

openFDA enforcement reports (food, drug and device), CC0, export dated 28 Sep 2026. Text in quotation marks is FDA's. The FDA enforcement report linked above is authoritative.

Provenance

Source: openFDA device enforcement reports (CC0), export dated 28 Sep 2026; records grouped by FDA event number. The class shown for the event is the most severe class among its records. Errors in processing are corrected at the next build; see corrections.